The LTECH DALI-CONTROLLERS is a four-channel DALI-2 dimmer controller for dimming LED lighting and resistive loads.
Input Voltage100-240V~
Input CurrentMax. 6.4A
Inrush Current in Loads:70A@10ms
Load Current12A/CH
Maximum Current12A
Out Current:200mA
Product overview
Overview. The LTECH DALI-CONTROLLERS is a four-channel DALI-2 dimmer controller for lighting control. It relies on the DALI protocol, known for its Manchester encoding transmission, global, group and addressable dimming, scene modes and brightness memory.
Main characteristics. Each channel delivers up to 12 A, for a maximum total output power of 1536 W (4 x 0-384 W). The output current is 4 channels x 1.6 A, with a maximum of 6.4 A, and the maximum input current is 6.4 A. The inrush current in loads is 70 A for 10 ms.
Interfaces and connectivity. The signal input and output both use the DALI-2 protocol, with a rated DALI input current below 2 mA and a maximum rated DALI output current of 220 mA. The controller provides short-circuit, over-temperature and over-current protection.
Power and environment. The input voltage is 100-240 V~ at 50/60 Hz, and the switching voltage is 250 V~. Capacitive load capacity is 2200 W at 230 V~ and 1100 W at 110 V~, resistive load is 1000 W at 230 V~ and 500 W at 110 V~. The housing is rated IP67 and the operating temperature range is -25 °C to 50 °C.
Mounting and integration. The unit mounts on a DIN rail or by screws. Its dimensions are L164 x W70 x H36 mm and its gross weight is 670 g. It integrates into an existing DALI-2 installation for dimming LED circuits.
Short-circuit, over-temperature, and over-current protection
Rated DALI input current:
<2mA
Rated DALI output current:
Max. 220mA
Resistive Load
1000W@230V~,500W@110V~
Switching Voltage:
250V~
Waterproof rating
IP67
Weight (G.W)
670g
Work Current
15V
Working Temp
-25°C~50°C
Working temperature
-25°C ~ 50°C
Applications and use cases
Architectures in which DALI-CONTROLLERS can play a role, derived from its category. This is not a compatibility statement: check the specifications against your requirements.
Hotel rooms keep heating, cooling and lights on while empty. A room control system links thermostats, switches, door contacts and lighting controllers so the room adapts to the guest’s presence
To check
Wired bus or wireless system, depending on renovation or new build
Link with the property management system for check-in and check-out
Behaviour when the guest is absent (setback temperature, lights off)
Associated system blocks
Climate controlSwitches and panelsPresence detectionLighting control
Street lights burn at full power all night. Lighting controllers on each luminaire, linked by LoRaWAN, dim, switch and report each light from a central platform
To check
Socket type on the luminaires (NEMA or Zhaga)
Dimming interface of the drivers
Gateway coverage across the network of streets
Associated system blocks
Luminaire controllersGateway
Need a complete solution?
Send a request for DALI-CONTROLLERS and the other parts of your project.
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
Current productLTECH
DALI-CONTROLLERS
4-Channel DALI-2 Controller for LED and Resistive Loads
What is recorded about the regulatory status and the life of this part.
Regulatory compliance
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
No advertising or analytics cookies. A single, strictly necessary cookie is set only if you sign in to your account. Your quote basket and comparison stay in your browser. Details