MacSync LCS X1 – LoRaWAN Capacitive Fuel Level Sensor

LoRaWAN Capacitive Fuel Level Sensor

Tank and Waste Level Sensors

  • Yes
Manufacturer part number
LORAWAN-CAPACITIVE-FUEL-LEVEL-SENSOR
Manufacturer
Macnman
Tank penetration needed
Yes

LoRaWAN capacitive fuel level sensor with a dip-stick probe for monitoring diesel in generator day tanks, tower reservoirs and equipment tanks.

Product overview

Overview. The Macnman MacSync LCS X1 is a LoRaWAN capacitive fuel level sensor with a dip-stick probe that measures diesel level to ±1% of full scale and transmits the data over LoRaWAN. Two concentric stainless steel tubes form a capacitor with the fuel as dielectric, so the measured capacitance rises with the submerged length. The sensor has no float and no sliding contact, and its reading is unaffected by vibration.

Main characteristics. Probe of 100 to 1400 mm, OEM customisable, in stainless steel with a Φ16 mm diameter. Reading resolution of 0.1 mm. Probe operating temperature from −35 to +70 °C. Designed for diesel and non-conductive hydrocarbons, calibrated per fuel. Event-triggered fuel theft alerts when an abnormal drop is detected.

Safety and power. Exd II C T5 flameproof design, gas group IIC, with a 100 °C maximum surface temperature. Powered by a 19 Ah industrial Li-SOCl₂ cell, with a stated battery life of more than 7 years at 60-minute uplinks, or a 9–36 V DC variant.

Connectivity and integration. LoRaWAN v1.0.4 Class A over OTAA, compatible with TTN, ChirpStack, MQTT, Orbiwise, Netmore or a private network server. Standard 5-hole flange or M20×1.5 thread, OEM customisable to the tank fitting. Configured over Bluetooth with the Maya app, then updated over the air. Made in Pune, India, WPC compliant on IN865 and RoHS conforming.

See all specifications

Highlights

  • Accuracy: ±1% of full scale, 0.1 mm resolution
  • Behaviour under vibration: Unaffected — reads submerged length
  • Choose it for: Diesel day tanks, tower reservoirs, equipment tanks
  • Hazardous-area design: Exd II C T5 flameproof probe design
  • Measurement Principle: Capacitance of fuel between concentric tubes
  • Measuring Range: 100–1400 mm probe, OEM customisable

Typical applications

Derived from the part category, not a compatibility statement.

See also

Technical questions

Ask a question

No published question about this part yet. Questions are reviewed before publication.

Request a quote