| Accessory | Mounting clip in the box |
| Accuracy | ±0.3 °C · ±3 % RH |
| AHU or plant room — Supply and return air conditions — DC variant on the duct or wall | Every 5 to 15 minutes |
| Boot (FPort 5) — Firmware and hardware version | Once after each join |
| Choose it for | Cold rooms, stores, sheds and sites spread over a campus, kilometres from the gateway |
| Config ACK (FPorts 16 to 21) — The setting now stored, with the battery level | After each downlink command is applied |
| Configuration — Maya app over Bluetooth · downlink — NFC app · downlink — AT commands · downlink | Bluetooth 5.0 app |
| Criterion — Macnman MacSync LTS X1 — Milesight EM300-TH — Dragino LHT65N | Seeed SenseCAP S2101 |
| DC-powered version — 9–36 V DC variant — Battery only | Battery only on the pages checked |
| FPort — What it sets — Range | Typical use |
| Freezer, −18 °C and below — Core air temperature — External probe inside, transmitter outside in the aisle | Every 5 to 15 minutes, alert the moment the core air warms |
| Humidity — 0–100 % RH · ±3 % RH from 10 to 90 %, ±5 % outside — 0–96 % RH · typically ±3 % RH | 0–100 % RH · accuracy not on the pages checked |
| Humidity, extremes — Below 10 % or above 90 % RH — ±5 % RH — 0.5 % RH | Dry rooms and saturated cold rooms; condensation is outside the operating condition |
| Humidity, mid range — 10 to 90 % RH — ±3 % RH — 0.5 % RH | Warehouses, archives, greenhouses and plant rooms |
| IN865 for India — Standard, WPC compliant — In the band list — By order code; not in the feature band list | IN865-867 listed |
| LoRaWAN — v1.0.4 · Class A, Class C via the app · OTAA — Class A · OTAA and ABP — v1.0.3 · Class A | v1.0.2 · Class A |
| Manufacturer — Macnman, Pune, India — Milesight, Xiamen, China — Dragino, Shenzhen, China | Seeed Studio, Shenzhen, China |
| Measures | Air temperature and relative humidity |
| Museum, archive or lab — Humidity drift and temperature swing — Internal sensor, wall mounted | Hourly, alert on humidity |
| Network | LoRaWAN® v1.0.4 through a gateway, or MacTalk device to device |
| Power | 19 Ah battery or 9–36 V DC |
| Probe | Internal sensor or external probe |
| Radio and battery | Both inside the zone; check the signal at the spot with the Maya app |
| Reading — Range — Accuracy — Resolution | Where it matters |
| Readings kept on the device — Yes, read back in the app; count not published — 2,800 entries — 3,328 records | Not on the pages checked |
| Reports every — Datasheet estimate — Uplinks per day | Typical use |
| Sampling (FPort 3) — 2 to 12 readings of temperature, humidity or both, oldest first, with battery and time | At the reporting interval, when sampling is on |
| SKUs | 8101 battery · 8102 DC · 8104 / 8103 MacTalk · 8105 BLE |
| Specification | −30 to +70 °C · ±0.3 °C from 0 to +70 °C · 0 to 100 % RH · ±3 % RH |
| Temperature, above freezing — 0 to +70 °C — ±0.3 °C — 0.1 °C | Vaccine fridges at 2 to 8 °C, pharma stores at 15 to 25 °C, server aisles |
| Temperature, below freezing — −30 to 0 °C — ±0.6 °C — 0.1 °C | Freezers and cold rooms at −18 to −25 °C, with the probe variant |
| Trigger (FPort 4) — ALARM or CLEAR, which limit, the reading and the low and high limits | The moment a reading leaves the band, and again when it returns |
| Uplink — What it carries | When it is sent |
| Warehouse or FMCG store — Humidity and heat at mezzanines and docks — Internal sensor, pole or wall mounted | Every 15 to 60 minutes |
| Where the element sits | Inside the sensor housing, reading the air around it |
| Where the transmitter goes | On the wall or pole in the zone itself |
| Zone — What is watched — Variant and placement | Reporting |
| Zones it suits | Cold rooms and chillers at 2 to 8 °C, pharma stores, warehouses, server rooms, sheds and greenhouses |