| Response time | ≤10 ms |
| Accuracy | ±0.05 % FS |
| Accuracy — ±0.05 % FS, about ±1.25 kPa (±0.0125 bar) — ±0.05 % FS, about ±2.5 kPa (±0.025 bar) | ±0.05 % FS, about ±5 kPa (±0.05 bar) |
| Accuracy and resolution — ±0.2 % FS · 0.1 kPa | 0.1 cm resolution · 100 ms response; accuracy not stated |
| Accuracy in metres of water head — About ±0.13 m — About ±0.25 m | About ±0.5 m |
| Alerts | Low and high limits within the sampling interval |
| BLE battery (9105 / 9110 / 9115) — 19 Ah Li-SOCl₂ cell — As the battery variant | Local reading and commissioning with the Maya app |
| Calibration certificate | None claimed (our weaker row) |
| Choose it when | The question is pressure on a line: networks, hydrants, pumps, process, hydraulics |
| Criterion — Macnman MacSync LPS Xx — Milesight EM500-PP — Dragino PS-LB — Decentlab DL-PR21 | Ellenex PTS2-L |
| Criterion — MacSync LPS X7 hydrostatic | MacRay LUS X1 ultrasonic |
| Cycle life | ≥1,000,000 cycles |
| Designed and made in — Pune, India; WPC compliant, RoHS — China — Switzerland | Australia and the United States |
| Enclosure — IP65 node, IP67 option · 152 × 62 × 43 mm | IP67 head, IP55 body · 96 × 96 × 28 mm |
| Hydrant ring main — Residual pressure for readiness — X1 battery variant on a test point of the ring main | Hourly; low-limit alert at the scheme' s figure (NBC 2016: 3.5 kg/cm² at the remotest hydrant) |
| Hydraulic machine — System pressure and slow decay — X3 DC variant | Every minute during runs; low alert |
| Installation | G1/4 tapping, clip and screws; no cable to the SCADA |
| LoRaWAN class — Class A by default; Class C for sites that need fast downlinks | Maya app |
| LoRaWAN DC (9102 / 9107 / 9112) — 9–36 V DC from the site — Continuous | Pump houses, plants, substations with power at the point |
| LPS X3 full scale — 10 — 100 — 101.97 — 1,020 | 1,450 |
| MacTalk battery / DC (9103–9104 / 9108–9109 / 9113–9114) — As above | A MacSet controller must act on the pressure with no gateway on site |
| Made in | Pune, India; WPC compliant |
| Measures | Line or vessel pressure, 0–2.5, 5 or 10 MPa |
| Measures — Hydrostatic pressure −10 to +10 kPa, about one metre of water head, with the sensor in the liquid | Distance to the surface, 3–450 cm, without touching the liquid |
| Overload — 200 % overload, 300 % burst — 150 % FS — 200 % — Not stated on the page | 300 % below 1 bar, 150 % above |
| Overload / burst | 200 % / 300 % |
| Page | This page |
| Page — Datasheet on the documentation site | Product page |
| Point — What is watched — Range, variant and placement | Reporting |
| Points per gateway or SIM | A ring of sensors on one gateway |
| Power | 19 Ah battery or 9–36 V DC |
| Power — 19 Ah battery, about 2 / 4 / 7+ years at 5 / 15 / 60-minute reports, or 9–36 V DC | 8 Ah battery, about 1 / 2 / 3+ years at 5 / 15 / 60-minute reports |
| Pressure reference — Not stated — Vented gauge — Not stated on the product page — Not stated on the page | Vented, sealed or absolute, selectable |
| Process line or gas receiver — Line pressure into SCADA — X2 or X3 DC variant on the plant' s supply | Every 1 to 5 minutes; both limits |
| Reading rate and transients | Sampled from 1 minute to 24 hours, plus limit events; not a transient-capture instrument (our weaker row) |
| Recurring cost | No SIM per point on your own gateway |
| Reporting interval — How often an uplink is sent, independent of sampling | Maya app · downlink |
| Reporting mode — Periodic, event-based or hybrid | Maya app · downlink |
| Rising main — Burst and pump-trip detection along the main — X1 battery variant at chambers along the route | Every 10 minutes; low-limit alert |
| Sampling interval — How often the transducer is read, from 1 minute to 24 hours | Maya app over BLE · downlink |
| Setting — What it does | Set from |
| Stored records — Not stated — 1,000 entries — Not on the page | Not stated |
| Temperature effect | ±0.02 % FS per °C |
| Thread and wetted element | G1/4, SS316 |
| Transducer sealing | IP65 |
| Variant — Power — Runtime | Choose it when |
| Vessels — Soap and chemical dispensers, bottles, small tanks, shallow vessels, diesel day tanks | Water tanks, sumps, canals, drains, bins and silos |
| What it is | SS316 transducer, LoRaWAN node, 19 Ah battery or DC and enclosure as one unit |
| Where it does not fit — Tanks deeper than about a metre of head; liquids that coat or attack the element | Foam, heavy vapour, narrow necks, surfaces closer than 3 cm |
| Where it fits | Many points across a zone, a ring main or a plant for monitoring and alerts |
| Where you meet it — MPa — bar — kg/cm² — m of water head | psi |
| Working pressure — 0–2.5 MPa (0–25 bar) — 0–5 MPa (0–50 bar) | 0–10 MPa (0–100 bar) |