| Accuracy | ±2 % of full scale (repeatability of the estimate) |
| Accuracy and resolution | ' ±2 %' over 0–50 °C · 0.01 |
| Battery life — ~2 years at 5-minute reports · ~4 years at 15-minute reports · ~7+ years at hourly reports | Estimated about 6.7 years at hourly uploads |
| BLE battery (8814 EC / 8819 pH / 8804 NPK) — 19 Ah Li-SOCl₂ cell — As the battery variant | Local reading, calibration and commissioning with the Maya app |
| Calibration certificate | Buffer solutions, user' s responsibility |
| Calibration parameters — The probe' s calibration settings, as described on the datasheets | Maya app · downlink |
| Card parameter — How the card gets it | What the LSS probes add between cards |
| Choose it when | Moisture and EC from one probe |
| Designed and made in | China |
| EC — Lab meter on a 1:5 suspension (GLOSOLAN procedure) | Continuous bulk EC on the LSS X3: dose arrival, salt build-up, leaching checks; a different number from the card' s, tracked as a trend |
| EC range, accuracy, resolution | 0–23 dS/m; accuracy not on the page |
| Electrode and calibration | Solid AgCl reference, pure-metal pH electrode; user calibration supported |
| Getting the data out | A notebook or an app |
| LoRaWAN and IN865 | Not stated |
| LoRaWAN class — Class A by default; Class C for sites that need fast downlinks | Maya app |
| MacTalk solar / battery (8812–8813 / 8817–8818 / 8802–8803) — As above | A MacSet controller must act on the reading with no gateway on site |
| N, P, K — Lab assays | A trend on the LSS X1 that shows a dose arrive and decay and times the next sample; the dose decision stays with the card |
| Network — LoRaWAN® v1.0.4, kilometres to a gateway — LoRaWAN® v1.0.4 | Existing 2.4 / 5 GHz Wi-Fi, no gateway |
| NPK | Not usually |
| Organic carbon — Lab assay | Lab only |
| Page — This page | Product page |
| pH — Lab meter on a soil:water suspension | Continuous on the LSS X4: drift, lime or acid response, polyhouse media swings |
| Power | Not stated |
| Power — 19 Ah battery, or 20 W solar + 8,000 mAh | Internal 19 Ah battery |
| Probe | Not stated |
| Probe and enclosure | Probe IP68, enclosure IP66; also reads soil temperature |
| Probe operating range | 5 to 45 °C · 5–95 % RH |
| Probe sealing | Corrosion-resistant industrial probe (rating not stated) |
| Range | 0–1,999 mg/kg per nutrient |
| Range, accuracy, resolution | No figures published |
| Reading | When someone walks the plot |
| Reads | Nitrogen, phosphorus and potassium estimates |
| Recurring cost | Labour for the round |
| Reporting interval — How often an uplink is sent, independent of sampling | Maya app · downlink |
| Reporting mode — Periodic, event-based or hybrid | Maya app · downlink |
| Resolution | 1 mg/kg |
| Response Time (T90) | <10 s |
| S, Zn, Fe, Cu, Mn, B (secondary and micronutrients) — Lab assays | Lab only; no in-field probe on this page reads them |
| Sampling interval — How often the probe is read, from 1 minute to 24 hours | Maya app over BLE · downlink |
| Setting — What it does | Set from |
| Site — What is watched — Probe, variant and placement | Reporting |
| SKUs | 8801 battery · 8800 solar · 8802/8803 MacTalk · 8804 BLE |
| Source — What it says | What to do with it |
| Stability | Not stated |
| Stated stability | Not stated |
| Tea, coffee or berry estate — pH in the acid band — LSS X4 pH, battery variant, one per section | Hourly; high limit at the top of the band |
| Temperature reference | Not on the page |
| Term — What it is | What the LSS X3 gives you |
| Thresholds — The low and high limits on EC, pH or the nutrient trend that trigger an immediate report | Maya app · downlink |
| Variant — Power — Runtime | Choose it when |
| What the maker says the figures are | ' Precise readings', no basis |
| What the reading is for | Timing lab samples; a trend, not a dose |
| What you get | A spot reading where you stand |
| Where it fits | The check beside any of the above |