Makerfabs SECPM2LW indoor LoRaWAN gateway built on the Semtech SX1302 chip, for deploying a LoRaWAN network compatible with several network servers and frequency plans.
Operating Temperature-20°C to 55°C
InterfacesEthernet RJ45 * 1
Input VoltageDC 12V - 2A
Flash32MB
RAMDDR2 128MB
Ethernet1xRJ45 (10M / 100 M), PoE PD support
Product overview
Makerfabs SECPM2LW. indoor LoRaWAN gateway built on the Semtech SX1302 chip, intended for deploying a LoRaWAN network.
Overview. The SECPM2LW is a standard LoRaWAN gateway that can connect to different LoRaWAN network servers. It supports the IN865/EU868/RU864 and US915/AU915/KR920/AS923 frequency plans, covering the 865 MHz to 923 MHz band.
Main characteristics. It provides 8 channels, a receive sensitivity of -125 dBm at 125 kHz with SF7 and a transmit power of up to 26 dBm. It complies with LoRaWAN protocol V1.0.3 in Class A, Class B and Class C. The MT7628 processor (MIPS24KEc at 580 MHz) is paired with 128 MB of DDR2 RAM and 32 MB of flash memory. The 3 dBi external LoRa antenna, 50 ohm impedance, is supplied with its base.
Interfaces and connectivity. One RJ45 Ethernet port (10/100 Mbit/s) provides the network connection and supports PoE powering (PD). Wi-Fi uses an internal antenna. Management is performed through a web interface.
Power and environment. Power is supplied at 12 V DC, 2 A. The operating temperature range is -20 °C to 55 °C, with relative humidity from 0 to 85 % non-condensing. Dimensions are 143.6 × 135 × 34 mm, connector not included.
Typical uses and integration. Compatible with network servers such as AWS, TTN or ChirpStack through Packet Forwarder or Basics Station mode, the gateway can also host a built-in LoRaWAN network server based on ChirpStack. Configuration is done through the SenseCAP Local Console over Wi-Fi or Ethernet, and remote supervision through the SenseCAP portal.
Makerfabs SECPM2LW indoor LoRaWAN gateway built on the Semtech SX1302 chip, for deploying a LoRaWAN network compatible with several network servers and frequency plans.
Operating Temperature-20°C to 55°C
InterfacesEthernet RJ45 * 1
Input VoltageDC 12V - 2A
Flash32MB
RAMDDR2 128MB
2. Datasheet extract (recorded values)
Parameter
Value
Antenna
Long Range: 3dBi External Antenna with Base
Antenna Impedance
50 Ohm
Channel
8
Dimension
143.6x135x34mm (connector not included)
Ethernet
1xRJ45 (10M / 100 M), PoE PD support
EU868
IN865/RU864
Flash
32MB
Frequency Plan
IN865/EU868/RU864/US915/AU915/KR920/AS923
Gateway Chip
SX1302
Input Voltage
DC 12V - 2A
Interfaces
Ethernet RJ45 * 1
Long Range Sensitivity
-125dBm @125KHz/SF7
Long Range TX Power
Up to 26 dBm
LoRaWAN Protocol
V1.0.3 Class A/Class B/Class C
Management Software
Web
Operating Temperature
-20°C to 55°C
Package
340*230*65mm
Processor
MT7628(MIPS24KEc@580MHz)
RAM
DDR2 128MB
Relative humidity
0% - 85% (non-condensing)
US915
US915/AU915/KR920/AS923
Wi-Fi
Internal Antenna
Integration
Points to check before using SECPM2LW in a design. They are derived from the recorded characteristics, not from the manufacturer's application circuits.
1Thermalrated operating range -20°C to 55°C — check it against the installation environment.
Power and communication
Input Voltage
DC 12V - 2A
Long Range TX Power
Up to 26 dBm
Check the exact pin assignment and the application circuit in the datasheet, or ask our experts.
Implementation checklist
Thermal : rated operating range -20°C to 55°C — check it against the installation environment.
Applications and use cases
Architectures in which SECPM2LW can play a role, derived from its category. This is not a compatibility statement: check the specifications against your requirements.
Energy bills give one total for the whole site. Submetering places meters and current sensors on each circuit or usage and collects their readings through a gateway, so consumption can be followed per building, floor or machine
To check
Number of circuits and phases to meter, and the current range of each
Wired Modbus bus or wireless LoRaWAN, depending on cabling access in the switchboards
Accuracy class required for internal allocation or for billing
Offices and classrooms get stuffy without anyone measuring why. Indoor air quality monitoring places CO2, VOC and particle sensors in the rooms and reports their values through a gateway, so ventilation can be adjusted to real occupancy
To check
Parameters to measure (CO2 alone or CO2, VOC and particles)
Battery-powered sensors or mains-powered sensors with display
Integration with the ventilation control or building management system
A leak under a sink or in a technical room is often found days later. Leak detection places wireless sensors where water can appear and sends an alert through a gateway as soon as one of them gets wet
To check
Locations at risk: kitchens, bathrooms, plant rooms, server rooms
Alert path (SMS, e-mail, application) and who receives it
Battery life and the way a low battery is reported
A fridge that drifts at night can ruin a whole stock. Temperature loggers in cold rooms and trucks report through a gateway or a tracker and raise an alert when a threshold is crossed
To check
Temperature range and accuracy required by the product
Record keeping required by the applicable regulations
A LoRaWAN project needs sensors, gateways, a network server and an application that work together. Sensor nodes report to indoor or outdoor gateways, which forward the data to the network server and the customer’s platform
To check
Regional frequency plan (EU868, US915 and others)
Network server: public, private or embedded in the gateway
A building’s energy, comfort and occupancy data sit in separate systems. Sensors, meters and gateways feed one model of the building, room by room, to compare scenarios and steer the installations
Milesight sensors, LoRaWAN gateways and cellular routers can be brought together on the Milesight Development Platform, which manages the devices and passes their data to other applications through an API and webhooks
To check
Development Platform for device management, API and webhooks, or another network server and application
Devices provisioned through Milesight RPS must have that provisioning removed before being added to the Development Platform
Data flows to the customer’s own application through webhooks
RAKwireless WisGate gateways run WisGateOS 2 and are managed from WisDM, RAKwireless’ cloud device management platform with a built-in network server, alongside RAK sensor nodes, radio modules and concentrators
To check
WisDM built-in network server, or a third-party one (ChirpStack, TTN/TTS, AWS IoT Core, Actility)
Remote configuration and updates of the gateways from WisDM
Regional frequency plan of the gateways and nodes
Associated system blocks
GatewaysSensors and modulesDevelopment boardsMounting
Need a complete solution?
Send a request for SECPM2LW and the other parts of your project.
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
What is recorded about the regulatory status and the life of this part.
Regulatory compliance
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
No advertising or analytics cookies. A single, strictly necessary cookie is set only if you sign in to your account. Your quote basket and comparison stay in your browser. Details