The GD72 is an outdoor ManThink LoRaWAN gateway that links LoRaWAN sensors to a network or IoT platform, with local processing and the ThinkLink server built in.
Operating temperature -C (commercial grade)0~65 ℃
Operating temperature -I (industrial grade)−40~70 ℃
Operating temperature -N (wide temperature range)−20~70 ℃
Power consumption (typical configuration)< 5 W
RAM1 GB
Storage16 GB eMMC
Product overview
Overview. The ManThink GD72 is an outdoor LoRaWAN gateway, a concentrator that receives frames from LoRaWAN sensors and forwards them to a network server or IoT platform. It includes the ThinkLink network server and IoT platform, with data buffering and local applications. Main characteristics — Semtech SX1302 concentrator, quad-core processor, 1 GB RAM and 16 GB eMMC, running Ubuntu. It supports Type A with 8 frequencies or Type D with 16 frequencies (125 kHz), with a receive sensitivity of −141 dBm (SF12, BW 125 kHz). Interfaces and connectivity — Ethernet backhaul at 1000M/100M, dual-band Wi-Fi 2.4/5 GHz in AP/Client mode, 4G LTE and BLE. Data forwarding over MQTT, MQTTS, HTTP or HTTPS, with integration for ThinkLink, ChirpStack, TTN, Basic Station or GWMP. Positioning and time synchronization via GPS, BDS and NTP. Power and environment — PoE/PoE+ supply at nominal 48 V, typical consumption below 5 W. IP67 ingress protection, pole or wall mounting, operating temperature depending on the variant: 0~65 ℃ (-C), −20~70 ℃ (-N) or −40~70 ℃ (-I). Typical uses — Outdoor installation to cover a site with LoRaWAN sensors, with local data processing before transmission to the cloud. Operations — Configuration and maintenance with gwTool7 or SSH, remote configuration and upgrades, automatic fault recovery, monitoring of CPU, RAM, storage, network and LoRa link. LoRaWAN regions available: AS923, CN470, EU433, EU868, AU915 and US915. Available on quotation from Atlas Electronics.
The GD72 is an outdoor ManThink LoRaWAN gateway that links LoRaWAN sensors to a network or IoT platform, with local processing and the ThinkLink server built in.
Operating temperature -C (commercial grade)0~65 ℃
Operating temperature -I (industrial grade)−40~70 ℃
Operating temperature -N (wide temperature range)−20~70 ℃
Points to check before using GD72 in a design. They are derived from the recorded characteristics, not from the manufacturer's application circuits.
1Thermalrated operating range 0~65 ℃ — check it against the installation environment.
2Thermalrated operating range −40~70 ℃ — check it against the installation environment.
3Thermalrated operating range −20~70 ℃ — check it against the installation environment.
Power and communication
Power consumption (typical configuration)
< 5 W
Power supply
PoE / PoE+, nominal 48 V
Transmit Power
-1: 27 dBm / -2: 22 dBm; maximum power tolerance ±2 dBm
Check the exact pin assignment and the application circuit in the datasheet, or ask our experts.
Implementation checklist
Thermal : rated operating range 0~65 ℃ — check it against the installation environment.
Thermal : rated operating range −40~70 ℃ — check it against the installation environment.
Thermal : rated operating range −20~70 ℃ — check it against the installation environment.
Applications and use cases
Architectures in which GD72 can play a role, derived from its category. This is not a compatibility statement: check the specifications against your requirements.
Energy bills give one total for the whole site. Submetering places meters and current sensors on each circuit or usage and collects their readings through a gateway, so consumption can be followed per building, floor or machine
To check
Number of circuits and phases to meter, and the current range of each
Wired Modbus bus or wireless LoRaWAN, depending on cabling access in the switchboards
Accuracy class required for internal allocation or for billing
Offices and classrooms get stuffy without anyone measuring why. Indoor air quality monitoring places CO2, VOC and particle sensors in the rooms and reports their values through a gateway, so ventilation can be adjusted to real occupancy
To check
Parameters to measure (CO2 alone or CO2, VOC and particles)
Battery-powered sensors or mains-powered sensors with display
Integration with the ventilation control or building management system
A leak under a sink or in a technical room is often found days later. Leak detection places wireless sensors where water can appear and sends an alert through a gateway as soon as one of them gets wet
To check
Locations at risk: kitchens, bathrooms, plant rooms, server rooms
Alert path (SMS, e-mail, application) and who receives it
Battery life and the way a low battery is reported
A fridge that drifts at night can ruin a whole stock. Temperature loggers in cold rooms and trucks report through a gateway or a tracker and raise an alert when a threshold is crossed
To check
Temperature range and accuracy required by the product
Record keeping required by the applicable regulations
A LoRaWAN project needs sensors, gateways, a network server and an application that work together. Sensor nodes report to indoor or outdoor gateways, which forward the data to the network server and the customer’s platform
To check
Regional frequency plan (EU868, US915 and others)
Network server: public, private or embedded in the gateway
A building’s energy, comfort and occupancy data sit in separate systems. Sensors, meters and gateways feed one model of the building, room by room, to compare scenarios and steer the installations
Milesight sensors, LoRaWAN gateways and cellular routers can be brought together on the Milesight Development Platform, which manages the devices and passes their data to other applications through an API and webhooks
To check
Development Platform for device management, API and webhooks, or another network server and application
Devices provisioned through Milesight RPS must have that provisioning removed before being added to the Development Platform
Data flows to the customer’s own application through webhooks
RAKwireless WisGate gateways run WisGateOS 2 and are managed from WisDM, RAKwireless’ cloud device management platform with a built-in network server, alongside RAK sensor nodes, radio modules and concentrators
To check
WisDM built-in network server, or a third-party one (ChirpStack, TTN/TTS, AWS IoT Core, Actility)
Remote configuration and updates of the gateways from WisDM
Regional frequency plan of the gateways and nodes
Associated system blocks
GatewaysSensors and modulesDevelopment boardsMounting
Need a complete solution?
Send a request for GD72 and the other parts of your project.
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
Current productManThink
GD72
Outdoor IP67 LoRaWAN gateway with built-in ThinkLink server
What is recorded about the regulatory status and the life of this part.
Regulatory compliance
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
No advertising or analytics cookies. A single, strictly necessary cookie is set only if you sign in to your account. Your quote basket and comparison stay in your browser. Details