BAROMETER – MEMS barometric pressure sensor with I2C/SPI digital output

MEMS barometric pressure sensor with I2C/SPI digital output

Barometric Pressure Sensors

  • -40-85℃
  • Condition: OSR_P
  • Operating Temperature
Manufacturer part number
BAROMETER
Manufacturer
MEMSensing

MEMS barometric pressure sensor with digital I2C/SPI output, designed to measure absolute atmospheric pressure between 30 and 110 kPa.

Product overview

Barometric pressure sensor MEMS. The MEMSensing barometer is an absolute pressure MEMS sensor in an LGA package, providing a digital signal linearly related to the external sensed pressure. The manufacturer describes the product as stable and reliable over a long period.

Main characteristics. Operating pressure range of 30 to 110 kPa. Typical absolute pressure accuracy of ±1 hPa over 300 to 1100 hPa, between 0 and 65 ℃. Typical relative accuracy of ±10 Pa for P = 900 to 1100 hPa. Typical long-term stability of ±1 hPa over 12 months. Typical absolute temperature accuracy of ±1 ℃ at 25 ℃.

Interfaces and connectivity. The device integrates a 24-bit Sigma-Delta ADC, OTP memory and an I2C/SPI communication interface. The external MCU reads the converted data and the calibration parameters stored in the OTP, and the current pressure in Pa is calculated with a specific calibration formula.

Power and environment. Supply voltage VDD from 1.7 to 3.6 V. Typical current consumption of 3.5 mA at 1 conversion per second with 256X, and typical standby current of 0.27 mA in sleep mode at 25 ℃. Operating temperature range from -40 to 85 ℃, with a temperature compensation range from -10 to 50 ℃. Typical TCO of 1 Pa/°C for P = 900 to 1100 hPa and T = 25 to 65 °C.

Typical uses. Atmospheric pressure measurement for altimetry and barometry, depth measurement in wearable electronics thanks to the medium-isolating waterproof gel, and integration into microcontroller-based electronic devices through I2C or SPI buses.

See all specifications

Highlights

  • MSP881 — Altimeter/Barometer — 2*2.5*0.99mm — Absolute — 30-130kPa — IIC: -40-85℃
  • MSP890 — Altimeter/Barometer — 2*2*0.77mm — Absolute — 30-130kPa — IIC: -40-85℃
  • MSP891 — Altimeter/Barometer — 2*2.5*0.99mm — Absolute — 30-130kPa — IIC: -40-85℃
  • MSPC04-GDS1 — Wearable electronic — 4*4*2mm — Gauge — 0-40kPa — IIC: -40-85℃
  • MSPC110-ADS1 — Wearable electronic — 2.7*2.7*1.77mm — Absolute — 30-110kPa — Digital: -40-85℃
  • MSPC15M-ADS1 — Wearable electronic — 2.7*2.7*1.77mm — Absolute — 30-1500kPa — IIC: -40-85℃

Good to know before integrating

  • Power: plan for a supply compatible with Condition: VDD; Min: 1.7; Max: 3.6; Units: V.
  • Thermal: rated operating range Min: -40; Typ: 25; Max: 85; Units: ℃ — check it against the installation environment.