The Merrytek MSA003S RC is a 5.8GHz microwave presence sensor with ON/OFF output, designed to detect movement in hallways, corridors and long passages.
Connection Interface4-pin terminal
Input/Output — Input voltage100-240V AC 50-60HZ
Input/Output — Loading instant peak current30A
Input/Output — Power consumption≤1W 230VDC
Input/Output — Working current50mA max
Sensor parameter — Radar Frequency5.8GHz±75MHZ ISM band
Product overview
Merrytek MSA003S RC is a 5.8GHz microwave presence sensor with ON/OFF output, designed for high mounting up to 12 m. Overview — The sensor uses a high-gain 5.8GHz microwave antenna and a wide detection range, operating in the 5.8GHz±75MHZ ISM band with a radar transmit power of 5mW maximum.
Main characteristics. Detection range of 12 to 15 m for the longer side and 3 to 5 m for the shorter side, based on a 3 m installation. The detecting angle is 150°, detection sensitivity adjustable from 25% to 100%, hold time from 5s to 30min, and daylight sensor from 5 to 150 lux or disabled. A remote control is available.
Power and output. Input voltage 100-240V AC 50-60HZ, rated voltage 220V AC, working current 50mA maximum, power consumption at most 1W, loading instant peak current 30A. Load capacity is 800 W resistive or 400 W inductive, connected through a 4-pin terminal.
Environment and certification. Surface mounting, working temperature 0℃ to +50℃, storage temperature -25℃ to +80℃. IP20 rating, RoHS compliant, FCC/RED certified. Dimensions 110x110x32 mm.
Typical uses. Presence detection in hallways, corridors and long passages to trigger automated lighting scenes.
Integration. When more than one load is switched in a single loop, Merrytek recommends adding an AC contactor on the output terminal to avoid momentary surge overload.
The Merrytek MSA003S RC is a 5.8GHz microwave presence sensor with ON/OFF output, designed to detect movement in hallways, corridors and long passages.
Connection Interface4-pin terminal
Input/Output — Input voltage100-240V AC 50-60HZ
Input/Output — Loading instant peak current30A
Input/Output — Power consumption≤1W 230VDC
Input/Output — Working current50mA max
2. Datasheet extract (recorded values)
Parameter
Value
Application environment — Installation
Surface mounting
Application environment — Storage temperature
-25℃~+80℃
Application environment — Working temperature
0℃…+50℃
Certificate Standard — Certificate
FCC/RED
Certificate Standard — Environmental requirements
Compliant to RoHS
Certificate Standard — IP rating
IP20
Connection Interface
4-pin terminal
Input/Output — Input voltage
100-240V AC 50-60HZ
Input/Output — Load capacity
800w resistive loading or 400w inductive loading
Input/Output — Loading instant peak current
30A
Input/Output — Power consumption
≤1W 230VDC
Input/Output — Rated voltage
220V AC
Input/Output — Working current
50mA max
MSA003S-RCV1.0-spec.pdf
2024-11-05 05
34:52
Product Size
110x110x32mm
Sensor parameter — Daylight Sensor
5-150lux/Disable
Sensor Parameter — Detecting Angle
150°
Sensor parameter — Detection Sensitivity
25%-100%
Sensor parameter — Hold Time
5s-30min
Sensor parameter — Mounting height
3-12m typical value: 3m/12m
Sensor parameter — Radar Frequency
5.8GHz±75MHZ ISM band
Sensor parameter — Radar transmit power
5mW Max
Sensor parameter — Radius detection range(based on 100% sensitivity and 3m mounting))
12-15m max detection range for the longer side and 3-5m max detection range for the short side based on 3m installation
Sensor parameter — Remote control
Available
Applications and use cases
Architectures in which MSA003S can play a role, derived from its category. This is not a compatibility statement: check the specifications against your requirements.
Meeting rooms are booked but empty, and some areas are always full. Presence sensors, radars and counting cameras measure how spaces are really used, room by room or at entrances
To check
Presence per room or counting at entrances, or both
Privacy requirements, which favour radar or anonymous counting
Hotel rooms keep heating, cooling and lights on while empty. A room control system links thermostats, switches, door contacts and lighting controllers so the room adapts to the guest’s presence
To check
Wired bus or wireless system, depending on renovation or new build
Link with the property management system for check-in and check-out
Behaviour when the guest is absent (setback temperature, lights off)
Associated system blocks
Climate controlSwitches and panelsPresence detectionLighting control
A building’s energy, comfort and occupancy data sit in separate systems. Sensors, meters and gateways feed one model of the building, room by room, to compare scenarios and steer the installations
To check
Data model and building plans available
Software platform hosting the twin
Sensor density needed for a useful model
Associated system blocks
SensorsMetersGateways
Need a complete solution?
Send a request for MSA003S and the other parts of your project.
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
No advertising or analytics cookies. A single, strictly necessary cookie is set only if you sign in to your account. Your quote basket and comparison stay in your browser. Details