The Netvox R207 gateway is the core of a smart home system on a proprietary LoRa network, with cloud connection and gateway mode support.
Operating Temperature-10℃~50℃
Power consumption5V/0.12A/0.6W (typical)
Storage humidity0~95%RH
Storage Temperature-20℃~60℃
Working/ Storage Humidity0 ~ 95%RH
Dimensions76.5mm * 37.0mm * 22.0mm
Product overview
Overview. The Netvox R207 is a LoRa gateway for smart home use. It acts as the core of the system and combines cloud technology with the Netvox proprietary LoRa protocol. It works as a gateway in the LoRa network, where it can be automatically screened and configured.
Main characteristics. The product supports the Netvox LoRa proprietary protocol, the Netvox cloud and gateway mode. Its modulation is LoRa/OOK, with a data transfer rate of 1.2 to 300 kbps that can be set as required. Maximum Tx power is 20 dBm ±1 dBm, and RX sensitivity is -136 dBm in LoRa (Spreading Factor 12, bit rate 293 bps) and -121 dBm in FSK (frequency deviation 5 kHz, bit rate 1.2 kbps). The antenna is built in.
Interfaces and connectivity. One RJ-45 data interface provides the wired link. The communication channel is chosen according to needs, and the frequency band can be selected between 410-525 MHz and 862-1020 MHz. Communication distance is up to 10 km, the actual distance depending on the environment.
Power and environment. Working input is 100 to 240 V AC, output 5 V/1 A DC. Typical power consumption is 5 V/0.12 A/0.6 W. Operating temperature is -10 °C to 50 °C, storage temperature -20 °C to 60 °C, and working/storage humidity 0 to 95 %RH. The shell is made of PC510 and measures 76.5 mm × 37.0 mm × 22.0 mm. A reset button restarts the device when pressed for five seconds.
Uses and integration. The R207 enables real remote control of a smart home, with energy saving functions. Third-party software can control it, for example an Android client for mode control.
The Netvox R207 gateway is the core of a smart home system on a proprietary LoRa network, with cloud connection and gateway mode support.
Operating Temperature-10℃~50℃
Power consumption5V/0.12A/0.6W (typical)
Storage humidity0~95%RH
Storage Temperature-20℃~60℃
Working/ Storage Humidity0 ~ 95%RH
2. Datasheet extract (recorded values)
Parameter
Value
Dimensions
76.5mm * 37.0mm * 22.0mm
Antenna Type
Built-in antenna
Communication Channel
( Users can choose according to their needs )
Communication Distance
Up to 10 km, the actual transmission distance depends on the environment.
Data Transfer Rate
1.2~300kbps ( can be set according to requirements )
Frequency Bandwidth
410-525MHz; 862-1020MHz; (User can select the desired frequency band)
Modulation
LoRa/OOK
Operating Temperature
-10℃~50℃
Power consumption
5V/0.12A/0.6W (typical)
Reset Button
Press and hold reset button for five seconds to reset and restart.
RX Sensitivity
-136dBm (LoRa,Spreading Factor=12, Bit Rate=293bps ); -121dBm (FSK,Frequency deviation=5kHz, Bit Rate=1.2kbps)
Shell material
PC510
Storage humidity
0~95%RH
Storage Temperature
-20℃~60℃
Tx Power
20dBm±1dBm; ( maximum, can be set according to requirements )
Working humidity
0~95%RH
Working Power
Input: 100~240V AC; Output: 5V/1A DC
Working/ Storage Humidity
0 ~ 95%RH
Integration
Points to check before using R207 in a design. They are derived from the recorded characteristics, not from the manufacturer's application circuits.
1Thermalrated operating range -10℃~50℃ — check it against the installation environment.
Power and communication
Power consumption
5V/0.12A/0.6W (typical)
Tx Power
20dBm±1dBm; ( maximum, can be set according to requirements )
Working Power
Input: 100~240V AC; Output: 5V/1A DC
Check the exact pin assignment and the application circuit in the datasheet, or ask our experts.
Implementation checklist
Thermal : rated operating range -10℃~50℃ — check it against the installation environment.
Applications and use cases
Architectures in which R207 can play a role, derived from its category. This is not a compatibility statement: check the specifications against your requirements.
Energy bills give one total for the whole site. Submetering places meters and current sensors on each circuit or usage and collects their readings through a gateway, so consumption can be followed per building, floor or machine
To check
Number of circuits and phases to meter, and the current range of each
Wired Modbus bus or wireless LoRaWAN, depending on cabling access in the switchboards
Accuracy class required for internal allocation or for billing
Offices and classrooms get stuffy without anyone measuring why. Indoor air quality monitoring places CO2, VOC and particle sensors in the rooms and reports their values through a gateway, so ventilation can be adjusted to real occupancy
To check
Parameters to measure (CO2 alone or CO2, VOC and particles)
Battery-powered sensors or mains-powered sensors with display
Integration with the ventilation control or building management system
A leak under a sink or in a technical room is often found days later. Leak detection places wireless sensors where water can appear and sends an alert through a gateway as soon as one of them gets wet
To check
Locations at risk: kitchens, bathrooms, plant rooms, server rooms
Alert path (SMS, e-mail, application) and who receives it
Battery life and the way a low battery is reported
A fridge that drifts at night can ruin a whole stock. Temperature loggers in cold rooms and trucks report through a gateway or a tracker and raise an alert when a threshold is crossed
To check
Temperature range and accuracy required by the product
Record keeping required by the applicable regulations
A LoRaWAN project needs sensors, gateways, a network server and an application that work together. Sensor nodes report to indoor or outdoor gateways, which forward the data to the network server and the customer’s platform
To check
Regional frequency plan (EU868, US915 and others)
Network server: public, private or embedded in the gateway
A building’s energy, comfort and occupancy data sit in separate systems. Sensors, meters and gateways feed one model of the building, room by room, to compare scenarios and steer the installations
Milesight sensors, LoRaWAN gateways and cellular routers can be brought together on the Milesight Development Platform, which manages the devices and passes their data to other applications through an API and webhooks
To check
Development Platform for device management, API and webhooks, or another network server and application
Devices provisioned through Milesight RPS must have that provisioning removed before being added to the Development Platform
Data flows to the customer’s own application through webhooks
RAKwireless WisGate gateways run WisGateOS 2 and are managed from WisDM, RAKwireless’ cloud device management platform with a built-in network server, alongside RAK sensor nodes, radio modules and concentrators
To check
WisDM built-in network server, or a third-party one (ChirpStack, TTN/TTS, AWS IoT Core, Actility)
Remote configuration and updates of the gateways from WisDM
Regional frequency plan of the gateways and nodes
Associated system blocks
GatewaysSensors and modulesDevelopment boardsMounting
Need a complete solution?
Send a request for R207 and the other parts of your project.
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
What is recorded about the regulatory status and the life of this part.
Regulatory compliance
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
No advertising or analytics cookies. A single, strictly necessary cookie is set only if you sign in to your account. Your quote basket and comparison stay in your browser. Details