The Netvox R313M is a LoRaWAN wireless doorbell control device that detects when a wireless doorbell is triggered and sends its status to the gateway.
Environment Temperature Range-20℃ to 55℃
Operating Temperature-20°C ~ 55 °C
Storage Temperature Range-40℃ to 85℃
Environment Humidity Range<90%RH (No condensation)
Frequency Range863MHz-928MHz 470MHz-510MHz
Operation Voltage RangeDC 2.4V to 3.0V
Product overview
Overview. The Netvox R313M is a LoRaWAN wireless doorbell control device. It detects whether the wireless doorbell is triggered and sends the doorbell status to the gateway.
Main characteristics. The R313M is LoRaWAN Class A compatible and uses an SX1276 wireless communication module with Frequency Hopping Spread Spectrum (FHSS). LoRa or FSK modulation is selected at configuration, and the visible line-of-sight transmission distance reaches 10 km, the actual distance depending on the environment. Receiving sensitivity reaches -136 dBm in LoRa (spreading factor 12, bit rate 293 bps) and -121 dBm in FSK (frequency deviation 5 kHz, bit rate 1.2 kbps). Configuration parameters can be set through a third-party software platform.
Interfaces and connectivity. The R313M supports the LoRaWAN bands EU863-870, US902-928, AU915-928, KR920-923, AS923-1, AS923-2, AS923-3, IN865-867 and CN470-510, the band being configured before shipment. It is applicable to the third-party platforms Actility / ThingPark, TTN and MyDevices / Cayenne. Data transfer rate ranges from 0.3 to 50 kbps in LoRa and from 1.2 to 300 kbps in FSK. The antenna is external.
Power and environment. The device is powered by two 3.0 V CR2450 button batteries in parallel, each with a capacity of 620 mAh. Operating voltage ranges from 2.4 V to 3.0 V, with a low voltage threshold of 2.4 V. Standby current is 14 µA at 3.0 V, maximum receiving current 11 mA and maximum transmitting current 120 mA at 3.0 V. Operating temperature ranges from -20 °C to 55 °C, with humidity below 90 %RH without condensation. Dimensions are 57 mm x 38.05 mm x 15.2 mm and weight is 45 g.
Integration. The R313M integrates into an existing LoRaWAN network thanks to its compatibility with the platforms listed above, to report the doorbell status to the supervision system.
No published question about this part yet. Questions are reviewed before publication.
Complete specifications
Every characteristic recorded for R313M, with where it comes from. Use the filters to find one quickly.
All specifications (30)
Characteristic
Value
Antenna Type
External antenna
Battery Measurement Accuracy
± 0.1V
Communication Distance
Up to 10 km; (visible linear obstacle-free transmission distance, actual transmission distance depends on the environment )
Data Transfer Rate
LoRa: 0.3kbps~50kbps; FSK: 1.2kbps~300kbps
Dimension
57 mm x38.05 mm x 15.2 mm
Emission current (max)
120mA / 3.0V
Environment Humidity
<90 %RH (No condensation)
Environment Humidity Range
<90%RH (No condensation)
Environment Temperature Range
-20℃ to 55℃
Frequency Range
863MHz-928MHz 470MHz-510MHz
Input power
2 x 3.0V CR2450 button batteries in parallel (The capacity of each CR2450 battery is 620mah.)
Low Battery Voltage Threshold
2.4V
Low Voltage Threshold
2.4V
Main Body Dimension
57mm x 38.05mm x 15.2mm
Modulation
LoRa/FSK (Note: You can choose one of them)
Modulation Method
LoRa/FSK (Note: choose one of them)
Operating Temperature
-20°C ~ 55 °C
Operation Voltage
DC 2.4V to 3.0V
Operation Voltage Range
DC 2.4V to 3.0V
Power supply
2 sections 3.0V CR2450 button batteries
Receiving Current (max)
11mA/ 3.0V
Receiving Sensitivity
-136dBm(LoRa,Spreading Factor=12,Bit Rate=293bps );; -121dBm (FSK,Frequency deviation=5kHz, Bit Rate=1.2kbps)
Standby Current
14uA/3.0V
Storage Temperature
-40°C ~ 85 °C
Storage Temperature Range
-40℃ to 85℃
Supportable LoRaWAN Band
EU863-870,US902-928,AU915-928,KR920-923,AS923-1,AS923-2,AS923-3,; IN865-867,CN470-510; (Note: The frequency band is optional and needs to be configured before shipment)
The Netvox R313M is a LoRaWAN wireless doorbell control device that detects when a wireless doorbell is triggered and sends its status to the gateway.
Environment Temperature Range-20℃ to 55℃
Operating Temperature-20°C ~ 55 °C
Storage Temperature Range-40℃ to 85℃
Environment Humidity Range<90%RH (No condensation)
Frequency Range863MHz-928MHz 470MHz-510MHz
2. Datasheet extract (recorded values)
Parameter
Value
Antenna Type
External antenna
Battery Measurement Accuracy
± 0.1V
Communication Distance
Up to 10 km; (visible linear obstacle-free transmission distance, actual transmission distance depends on the environment )
Data Transfer Rate
LoRa: 0.3kbps~50kbps; FSK: 1.2kbps~300kbps
Dimension
57 mm x38.05 mm x 15.2 mm
Emission current (max)
120mA / 3.0V
Environment Humidity
<90 %RH (No condensation)
Environment Humidity Range
<90%RH (No condensation)
Environment Temperature Range
-20℃ to 55℃
Frequency Range
863MHz-928MHz 470MHz-510MHz
Input power
2 x 3.0V CR2450 button batteries in parallel (The capacity of each CR2450 battery is 620mah.)
Low Battery Voltage Threshold
2.4V
Low Voltage Threshold
2.4V
Main Body Dimension
57mm x 38.05mm x 15.2mm
Modulation
LoRa/FSK (Note: You can choose one of them)
Modulation Method
LoRa/FSK (Note: choose one of them)
Operating Temperature
-20°C ~ 55 °C
Operation Voltage
DC 2.4V to 3.0V
Operation Voltage Range
DC 2.4V to 3.0V
Power supply
2 sections 3.0V CR2450 button batteries
Receiving Current (max)
11mA/ 3.0V
Receiving Sensitivity
-136dBm(LoRa,Spreading Factor=12,Bit Rate=293bps );; -121dBm (FSK,Frequency deviation=5kHz, Bit Rate=1.2kbps)
Standby Current
14uA/3.0V
Storage Temperature
-40°C ~ 85 °C
Storage Temperature Range
-40℃ to 85℃
Supportable LoRaWAN Band
EU863-870,US902-928,AU915-928,KR920-923,AS923-1,AS923-2,AS923-3,; IN865-867,CN470-510; (Note: The frequency band is optional and needs to be configured before shipment)
Check the exact pin assignment and the application circuit in the datasheet, or ask our experts.
Implementation checklist
Thermal : rated operating range -20°C ~ 55 °C — check it against the installation environment.
Applications and use cases
Architectures in which R313M can play a role, derived from its category. This is not a compatibility statement: check the specifications against your requirements.
Energy bills give one total for the whole site. Submetering places meters and current sensors on each circuit or usage and collects their readings through a gateway, so consumption can be followed per building, floor or machine
To check
Number of circuits and phases to meter, and the current range of each
Wired Modbus bus or wireless LoRaWAN, depending on cabling access in the switchboards
Accuracy class required for internal allocation or for billing
Offices and classrooms get stuffy without anyone measuring why. Indoor air quality monitoring places CO2, VOC and particle sensors in the rooms and reports their values through a gateway, so ventilation can be adjusted to real occupancy
To check
Parameters to measure (CO2 alone or CO2, VOC and particles)
Battery-powered sensors or mains-powered sensors with display
Integration with the ventilation control or building management system
A leak under a sink or in a technical room is often found days later. Leak detection places wireless sensors where water can appear and sends an alert through a gateway as soon as one of them gets wet
To check
Locations at risk: kitchens, bathrooms, plant rooms, server rooms
Alert path (SMS, e-mail, application) and who receives it
Battery life and the way a low battery is reported
A fridge that drifts at night can ruin a whole stock. Temperature loggers in cold rooms and trucks report through a gateway or a tracker and raise an alert when a threshold is crossed
To check
Temperature range and accuracy required by the product
Record keeping required by the applicable regulations
A LoRaWAN project needs sensors, gateways, a network server and an application that work together. Sensor nodes report to indoor or outdoor gateways, which forward the data to the network server and the customer’s platform
To check
Regional frequency plan (EU868, US915 and others)
Network server: public, private or embedded in the gateway
A building’s energy, comfort and occupancy data sit in separate systems. Sensors, meters and gateways feed one model of the building, room by room, to compare scenarios and steer the installations
Milesight sensors, LoRaWAN gateways and cellular routers can be brought together on the Milesight Development Platform, which manages the devices and passes their data to other applications through an API and webhooks
To check
Development Platform for device management, API and webhooks, or another network server and application
Devices provisioned through Milesight RPS must have that provisioning removed before being added to the Development Platform
Data flows to the customer’s own application through webhooks
RAKwireless WisGate gateways run WisGateOS 2 and are managed from WisDM, RAKwireless’ cloud device management platform with a built-in network server, alongside RAK sensor nodes, radio modules and concentrators
To check
WisDM built-in network server, or a third-party one (ChirpStack, TTN/TTS, AWS IoT Core, Actility)
Remote configuration and updates of the gateways from WisDM
Regional frequency plan of the gateways and nodes
Associated system blocks
GatewaysSensors and modulesDevelopment boardsMounting
Need a complete solution?
Send a request for R313M and the other parts of your project.
Answers to the questions that the recorded characteristics of R313M can answer. A question is not asked when nothing is recorded to answer it.
1Does it support CAN bus?
Yes — recorded under "Modulation": LoRa/FSK (Note: You can choose one of them).
2Does it support LoRaWAN?
Yes — recorded under "Supportable LoRaWAN Band": EU863-870,US902-928,AU915-928,KR920-923,AS923-1,AS923-2,AS923-3,; IN865-867,CN470-510; (Note: The frequency band is optional and needs to be configured before shipment).
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
What is recorded about the regulatory status and the life of this part.
Regulatory compliance
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
No advertising or analytics cookies. A single, strictly necessary cookie is set only if you sign in to your account. Your quote basket and comparison stay in your browser. Details