The Netvox RA02D1 is a wireless liquefied petroleum gas (LPG) detector that measures LPG concentration from 500 to 10000 ppm and sounds an 85 dB alarm at 3 meters.
Ambient temperature range-20℃ – 55℃
Frequency Range863MHz-928MHz 470MHz-510MHz
Liquid Petroleum Gas Measurement Range500 –10000 ppm
Operating Current<150mA
Dimensions106 mm (D) x 36 mm (H)
Alarm Decibel Value85dB (3 meters away)
Product overview
Overview. The Netvox RA02D1 is a wireless liquefied petroleum gas (LPG) detector that measures LPG concentration in the environment over a range of 500 to 10000 ppm. It sounds an 85 dB alarm at 3 meters.
Main characteristics. Powered at 12 V DC / 1 A by a power adapter, it draws less than 150 mA in operation. Dimensions are 106 mm (D) x 36 mm (H). It operates between -20 ℃ and 55 ℃.
Interfaces and connectivity. It communicates over LoRaWAN® with LoRa or FSK modulation. The EU863-870, US902-928, AU915-928, KR920-923, AS923-1, AS923-2, AS923-3, IN865-867 and CN470-510 bands are configured at the factory before shipment. The antenna is built in. Range reaches 10 km in line of sight, and the actual distance depends on the environment.
Integration. Tx power depends on the band: 16 dBm in EU868, 20 dBm in US915, 20 dBm in AU915, 14 dBm in KR920, 16 dBm in AS923, 19.15 dBm in CN470 and 20 dBm in IN865. Receive sensitivity is -136 dBm in LoRa (spreading factor 12, bit rate 293 bps) and -121 dBm in FSK (frequency deviation 5 kHz, bit rate 1.2 kbps). Data rate ranges from 0.3 to 50 kbps in LoRa and from 1.2 to 300 kbps in FSK.
The Netvox RA02D1 is a wireless liquefied petroleum gas (LPG) detector that measures LPG concentration from 500 to 10000 ppm and sounds an 85 dB alarm at 3 meters.
Ambient temperature range-20℃ – 55℃
Frequency Range863MHz-928MHz 470MHz-510MHz
Liquid Petroleum Gas Measurement Range500 –10000 ppm
Architectures in which RA02D1 can play a role, derived from its category. This is not a compatibility statement: check the specifications against your requirements.
Diseases and water stress are noticed once the crop is already affected. A weather station, soil probes and sensor nodes in the field report conditions through an outdoor gateway
To check
Crops, plots and measurement depth of the soil probes
A LoRaWAN project needs sensors, gateways, a network server and an application that work together. Sensor nodes report to indoor or outdoor gateways, which forward the data to the network server and the customer’s platform
To check
Regional frequency plan (EU868, US915 and others)
Network server: public, private or embedded in the gateway
Milesight sensors, LoRaWAN gateways and cellular routers can be brought together on the Milesight Development Platform, which manages the devices and passes their data to other applications through an API and webhooks
To check
Development Platform for device management, API and webhooks, or another network server and application
Devices provisioned through Milesight RPS must have that provisioning removed before being added to the Development Platform
Data flows to the customer’s own application through webhooks
RAKwireless WisGate gateways run WisGateOS 2 and are managed from WisDM, RAKwireless’ cloud device management platform with a built-in network server, alongside RAK sensor nodes, radio modules and concentrators
To check
WisDM built-in network server, or a third-party one (ChirpStack, TTN/TTS, AWS IoT Core, Actility)
Remote configuration and updates of the gateways from WisDM
Regional frequency plan of the gateways and nodes
Associated system blocks
GatewaysSensors and modulesDevelopment boardsMounting
Seeed SenseCAP sensors connect to Seeed’s SenseCAP cloud platform and app, and Seeed edge computers, camera modules, Grove and XIAO boards complete the chain for custom devices and local processing
To check
SenseCAP cloud platform and app, or the customer’s own network server
Prototype on Grove and XIAO, then move to industrial versions
Local processing on the edge computers or in the cloud
Associated system blocks
SensorsEdge computingDevelopment boards
Need a complete solution?
Send a request for RA02D1 and the other parts of your project.
Answers to the questions that the recorded characteristics of RA02D1 can answer. A question is not asked when nothing is recorded to answer it.
1Does it support LoRaWAN?
Yes — recorded under "Supported LoRaWAN Frequency Plan": EU863-870, US902-928, AU915-928, KR920-923, AS923-1, AS923-2, AS923-3, IN865-867, CN470-510; (Note: optional, to be done in the factory configuration).
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
SenseCAP SOLO CO2 5000 (A1) - NDIR CO2 Sensor, MODBUS-RTU RS485 & SDI-12
A
The default output of the sensor is RS485 and the slave address is 1. If you need to use SDI-12 output, you need to open the cover and push the button on the board to ''1'' and ''2''. At the same time, check whether the wire sequence is correct.
What is recorded about the regulatory status and the life of this part.
Regulatory compliance
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
No advertising or analytics cookies. A single, strictly necessary cookie is set only if you sign in to your account. Your quote basket and comparison stay in your browser. Details