Niubol NBL-W-NS noise level sensor for continuous environmental and industrial sound monitoring, with RS485 Modbus RTU output.
Operating Temperature-15 to +50°C
Frequency Range31.5 Hz–8 kHz
Measurement Range30–130 dB
InterfaceRS485
Power consumptionApprox. 20 mW @ 12V DC
Audio / Voice RecordingNo
Product overview
Overview. The Niubol NBL-W-NS is an environmental noise level sensor designed for continuous sound-level monitoring in urban, industrial and construction environments.
Main characteristics. It measures noise levels from 30 to 130 dB over a frequency range of 31.5 Hz to 8 kHz using a 0.5-inch condenser microphone. Its time response is fast, with T = 200 ms.
Interfaces and connectivity. The RS485 Modbus RTU output allows connection to PLCs, data loggers, RTUs and IoT gateways. A 4–20mA output is available depending on the configuration. The device address is adjustable from 0 to 255, with a baud rate of 9600 bps, no parity and 1 or 2 stop bits. The minimum communication interval is ≥1000 ms.
Power and environment. The sensor is powered by DC 12V and consumes approx. 20 mW @ 12V DC. Its ABS plastic housing provides an IP65 protection rating. It operates from -15 to +50°C at humidity below 80% RH.
Typical uses. It suits digital monitoring and IoT systems, including environmental noise, industrial monitoring and regulatory projects. It can be installed indoors, in factories, on construction sites, roadside, in parks or at environmental stations.
Integration. Multiple Modbus devices can share a properly designed RS485 bus. Complete and verify the wiring before applying power, and choose a measurement location representative of the noise environment being monitored.
Niubol NBL-W-NS noise level sensor for continuous environmental and industrial sound monitoring, with RS485 Modbus RTU output.
Operating Temperature-15 to +50°C
Frequency Range31.5 Hz–8 kHz
Measurement Range30–130 dB
InterfaceRS485
Power consumptionApprox. 20 mW @ 12V DC
2. Datasheet extract (recorded values)
Parameter
Value
Audio / Voice Recording
No
Automatic Data Collection
Yes, with logger / PLC
Baud rate
9600 bps
Black / Green
Power Ground
Blue
RS485 B− / RX
Calibration Documents
Specify any required calibration certificate, traceability or tender documentation
Communication Item
Specification
Compliance Monitoring
Follow the applicable local standard for sensor height, distance from buildings, measurement duration and site selection.
Continuous Monitoring
Yes
Data transmission
Local PLC / logger or remote 4G / Ethernet monitoring through a gateway
Device Address
0–255
Frequency Range
31.5 Hz–8 kHz
Frequency Spectrum Analyzer
Not specified as a spectrum-analysis output
Function
NBL-W-NS
Housing
ABS Plastic
Installation Environment
Indoor, factory, construction site, roadside, park or environmental station
Installation Item
Recommendation
Interface
RS485
Maximum Output Impedance
200 Ω
Measurement Position
Choose a location representative of the noise environment being monitored.
Measurement Range
30–130 dB
Microphone
Condenser Microphone
Microphone Area
Do not obstruct or cover the acoustic sensing section.
Microphone Size
0.5 inch
Minimum Communication Interval
≥1000 ms
Model
NBL-W-NS
Monitoring Method
Continuous fixed monitoring
Monitoring Purpose
General environmental monitoring, industrial monitoring or regulatory project
Multi-Sensor Network
Multiple Modbus devices can share a properly designed RS485 bus
Nearby Surfaces
Consider sound reflection from walls, machinery and structures when selecting the measurement point.
Operating Humidity
<80% RH
Operating Temperature
-15 to +50°C
Outdoor Mounting
Secure the sensor firmly and keep connectors, cable joints and associated electronics appropriately protected.
Output
RS485 Modbus or 4–20mA according to the receiving equipment
Output Options
RS485 Modbus RTU / 4–20mA depending on configuration
Parity
None
Power consumption
Approx. 20 mW @ 12V DC
Power supply
DC 12V
Product Type
Environmental Noise Level Sensor
Products
Weather Stations
Protection rating
IP65
Protocol
Modbus RTU
Quantity
Sample, pilot site or multi-point monitoring project
RED
Power Positive
RS485 Data Output
Yes
RS485 Integration
Yes
Selection Item
Information to Confirm
Signal Type
Digital
Sound Level Measurement
Yes, 30–130 dB
Stop Bits
1 or 2
Time Response
Fast Response, T = 200 ms
Typical application
Digital monitoring and IoT systems
Typical Receiver
PLC, RTU, Data Logger, IoT Gateway
Wire Color
Function
Wiring
Complete and verify wiring before applying power.
Yellow
RS485 A+ / TX
Integration
Points to check before using NOISE-SENSOR in a design. They are derived from the recorded characteristics, not from the manufacturer's application circuits.
1Thermalrated operating range -15 to +50°C — check it against the installation environment.
Power and communication
Power consumption
Approx. 20 mW @ 12V DC
Power supply
DC 12V
Check the exact pin assignment and the application circuit in the datasheet, or ask our experts.
Implementation checklist
Thermal : rated operating range -15 to +50°C — check it against the installation environment.