Diffusion-type outdoor ozone (O3) sensor using four-electrode electrochemical sensing over a 0-5 ppm range, featuring a pole-mounted IP65 housing and RS485 Modbus RTU output.
Product overview
Overview. The Niubol O3-SENSOR outdoor ozone sensor is engineered for ambient air trend monitoring, industrial boundary screening, and weather station integration. It utilizes a four-electrode electrochemical sensing method with natural diffusion sampling to measure ambient O3 concentrations.
Metrological Performance. The sensor operates over a 0-5 ppm measurement range with a 0.001 ppm resolution increment and an accuracy of +/-5% FS (equivalent to +/-0.25 ppm across the 5 ppm span). Measurement data is transmitted over an RS485 Modbus RTU output interface to a compatible data logger or RTU.
Installation and Operating Conditions. Powered by a 12 VDC supply, the unit features an IP65 protective housing designed for pole-mounted assembly with unobstructed airflow to the diffusion inlet. Certified to ISO, CE, and RoHS standards, it operates across -30 to 50 degrees C and 15-90% RH.
Diffusion-type outdoor ozone (O3) sensor using four-electrode electrochemical sensing over a 0-5 ppm range, featuring a pole-mounted IP65 housing and RS485 Modbus RTU output.
Observed condition — First checksNext decision
ProductsWeather Stations
2. Datasheet extract (recorded values)
Parameter
Value
A flat low value after wet weather — Inlet condition, local humidity, channel status and any substituted zero.
Distinguish a sampling or data fault from a genuine concentration change before applying a correction.
A step after work on the mast — Orientation, inlet obstruction, location change and logger configuration.
Restore or document the changed installation before joining the records as one unchanged point.
Accuracy — +/-5% FS
Equivalent to +/-0.25 ppm over the 5 ppm span; review suitability for the required concentration differences.
Environment — -30 to 50 degrees C; 15-90% RH
Assess extended fog, condensation and site extremes before accepting the application.
Housing protection — IP65
Not an immersion rating or a promise of measurement performance with a wet, blocked inlet.
Mounting — Pole-mounted assembly
Use the intended bracket orientation and preserve the inlet opening.
Observed condition — First checks
Next decision
Power demand / cable — Confirm for the ordered channel set, jacket, length and termination
Complete the remote-power and field-connection design before installation.
Products
Weather Stations
Range / resolution — 0-5 ppm / 0.001 ppm
Do not interpret the decimal increment as low-concentration accuracy.
Sampling — Diffusion
Ambient air must reach the intended inlet without an added unapproved sample path.
Supply / output — 12 VDC / RS485 Modbus RTU
A compatible logger or RTU is needed for acquisition.
Review expected interfering gases and the required comparison method.
Two sites disagree — Exposure, timestamps, averaging periods and whether they sample the same air.
Use an appropriate common-exposure comparison rather than forcing their traces to match.
Applications and use cases
Architectures in which O3-SENSOR can play a role, derived from its category. This is not a compatibility statement: check the specifications against your requirements.
Hotel rooms keep heating, cooling and lights on while empty. A room control system links thermostats, switches, door contacts and lighting controllers so the room adapts to the guest’s presence
To check
Wired bus or wireless system, depending on renovation or new build
Link with the property management system for check-in and check-out
Behaviour when the guest is absent (setback temperature, lights off)
Associated system blocks
Climate controlSwitches and panelsPresence detectionLighting control
Need a complete solution?
Send a request for O3-SENSOR and the other parts of your project.
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
What is recorded about the regulatory status and the life of this part.
Regulatory compliance
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
No advertising or analytics cookies. A single, strictly necessary cookie is set only if you sign in to your account. Your quote basket and comparison stay in your browser. Details