NBL-W-PPT – PV module temperature sensor with thermistor element

PV module temperature sensor with thermistor element

General Industrial Sensors & Transmitters

  • Weather Stations
Manufacturer part number
PV-MODULE-TEMPERATURE-SENSOR
Manufacturer
Niubol
Products
Weather Stations

The Niubol NBL-W-PPT is a PV module temperature sensor with a thermistor contact element, bonded with thermally conductive silicone to the module rear surface to measure backsheet temperature.

Product overview

Overview. The NBL-W-PPT is a Niubol PV module temperature sensor with a thermistor contact element, designed to measure the temperature of the module rear surface at a bonded point. It does not directly measure every cell temperature or identify all hot spots across the module.

Main characteristics. Measurement range of -50 to +100 °C or -20 to +50 °C depending on the version selected, with an accuracy of +/-0.5 °C. Power of 0.15 W and probe mass of 125 g. Standard cable of 5 m; alternative length and jacket by agreement.

Power and outputs. Supply versions of 5, 12 or 24 V DC, chosen at ordering. Outputs 4-20 mA, 0-2.5 V, 0-5 V or RS485 option. For the voltage version the load resistance must be at least 1 kohm; for the current version it must not exceed 250 ohms.

Interfaces and connectivity. The RS485 version supports Modbus RTU, subject to the settings and data definition supplied by the manufacturer. The selected output must match the supported receiving input.

Environment and mounting. Working environment from -50 to +100 °C and 0-100% RH. Mounting with thermally conductive silicone at the selected rear-surface point, to be checked against the project's bonding method. The cable should be supported along the module support so the probe does not carry its weight.

Typical uses. Module temperature monitoring for PV performance analysis, correlated with irradiance and production. The measurement should be time-aligned with the other recorded quantities.

See all specifications

Highlights

  • Cable — Standard 5 m; alternative length and jacket by agreement: Review UV, edges, movement and extension routing.
  • Load resistance — Voltage version: at least 1 kohm; current version: no more than 250 ohms: Check the input and complete applicable circuit.
  • Measurement range — -50 to +100 degrees C or -20 to +50 degrees C: Program the actual selected span in the receiving channel.
  • Output — 4-20 mA, 0-2.5 V, 0-5 V or RS485 option: Choose the supported receiving input and actual conversion.
  • Power and probe mass — 0.15 W; probe 125 g: Support the sensor and cable independently as required.
  • Products: Weather Stations

Typical applications

Derived from the part category, not a compatibility statement.

See also

Technical questions

Ask a question

No published question about this part yet. Questions are reviewed before publication.

Request a quote