NYCSUL-503 – Non-corrosive liquid ultrasonic level transmitter, remote sensor

Non-corrosive liquid ultrasonic level transmitter, remote sensor

Level Transmitters

  • 0.25%-0.5%F.S
  • 0.2-0.6m
  • Ex(ia)ⅡCT6
  • Segregated Type
Manufacturer part number
15668912-00
Manufacturer
Nuoying
Accuracy
0.25%-0.5%F.S
Blind Zone
0.2-0.6m

Nuoying NYCSUL-503 ultrasonic level transmitter for non-contact level measurement of non-corrosive liquids, with 4-20 mA, HART or RS485 output and Ex(ia)ⅡCT6 explosion-proof version.

Product overview

Nuoying NYCSUL-503 ultrasonic level transmitter — This ultrasonic level transmitter from Nuoying continuously measures the level of non-corrosive liquids without contact in varied environments. It is offered in integrated or segregated (remote sensor) type.

Main characteristics. Accuracy of 0.25% to 0.5% F.S, resolution of 3 mm or 0.1% F.S (whichever is greater), blind zone of 0.2 to 0.6 m. Level ranges from 5 m to 70 m depending on the range. The transmitter displays level, distance, transmitted value, ambient temperature, echo state and alarms, and allows upper and lower limit settings.

Interfaces and connectivity. 4...20 mA, HART or RS485 (optional) signal output. Relay outputs of 250 V AC / 8 A and 30 V DC / 5 A, with programmable states. Process connection by thread, flange or bracket mounting (optional). Standard sensor cable of 10 metres, up to 200 metres.

Power and environment. Power supply 24 V DC or 220 V AC; 12 V DC available. Ambient temperature of -20 to +60 °C for the meter and -20 to +80 °C for the sensor, process temperature of -20 to +80 °C, working pressure of 2 bar (5 bar for the explosion-proof type). Protection rating IP66 in standard version, IP65 or IP68 depending on meter and sensor.

Safety. Explosion-proof certified Ex(ia)ⅡCT6 for liquid measurement in explosive atmospheres, except hydrogen, acetylene and carbon disulfide.

Typical uses. Level measurement in tanks and reservoirs of non-corrosive liquids, including oils, with the signal sent to a PLC or supervision system via RS485 or HART.

Integration. Connection to a PLC or supervision system is made through the 4...20 mA or RS485 output, with high and low level alarms available as relays.

See all specifications

Highlights

  • Accuracy: 0.25%-0.5%F.S
  • Blind Zone: 0.2-0.6m
  • Cable of Sensor: — Null: Standard: 10 Meters, Max to 200 Meters
  • Certification: Explosion proof certificate
  • Communication: RS485 Communications (optional)
  • Explore Proof:: Ex(ia)ⅡCT6

See also

Technical questions

Ask a question

No published question about this part yet. Questions are reviewed before publication.

Similar products

All Level Transmitters
Request a quote