NYDE – Tuning fork resonance density meter with Modbus RTU output

Tuning fork resonance density meter with Modbus RTU output

Modular DIN-Rail Remote I/O Modules

  • -50℃~+150℃
  • -40~130℃,-50~150℃
  • 0–600 cP
  • Digital sensor
Manufacturer part number
16067439-00
Manufacturer
Nuoying
Medium temperature range
-50℃~+150℃
Operating Temperature
-40~130℃,-50~150℃

NYDE plug-in tuning fork resonance density meter for online liquid density measurement in pipelines and tanks. Outputs 4-20 mA or RS485 Modbus RTU.

Product overview

Overview. The Nuoying NYDE is a plug-in tuning fork resonance density meter for online measurement of liquid density. It is installed in pipelines and in open or closed tanks, and the density of the medium is determined directly from the vibration frequency of the tuning fork immersed in it. Main characteristics — Measuring range is 0 to 2.5 g/cc (0 to 2500 kg/m3) and 0 to 100.0%. Accuracy is ±0.002 g/cc (±2 kg/m3) or ±0.5%, and repeatability is ±0.001 g/cc (±0.2 kg/m3) or ±0.1%. Working pressure reaches 4 MPa and the fluid viscosity range is 0 to 600 cP. The sensor includes a digital temperature sensor providing temperature compensation. Interfaces and connectivity — Signal output is available as 4-20 mA analog, 0-1000 Hz frequency or RS485 Modbus RTU. Power and environment — Power supply 24 VDC, 50 mA or more. Operating temperature -40 to 130 °C, medium temperature -50 to 150 °C, protection level IP67. The fork body is coated with standard PTFE or PFA and the shell is aluminum alloy. Process connection DIN 50 PN16 or DIN 50 PN40, with retractable T-shaped side-opening installation. Typical uses — Process control on products where density is the basic parameter, interface detection in multi-product pipelines, end-point monitoring of reactors and interface detection in separators, notably in petrochemical, food, pharmaceutical and mineral processing industries. Limitations — Not suitable for unstable flow, pipelines smaller than DN100 or flocculent solutions such as pulp. The RS485 Modbus RTU output allows integration into a PLC or supervisory system.

See all specifications

Highlights

  • Accuracy: ± 0.002 G /cc (± 2 Kg/m3) ,±0.5%
  • Analog signal output: 4-20 mA,0-1000Hz,RS485 Modbus RTU
  • Built-in temperature sensor: Digital sensor
  • Calibration range: 0 – 2.5 g /cc (0 – 2500 kg/m3),0~100.0%
  • Certification: Explosion-proof certificate
  • Flow rate — The flow rate through the fork is 0-1m/s: The main pipe flow rate is 1-5m/s

Typical applications

Derived from the part category, not a compatibility statement.

Good to know before integrating

  • Thermal: rated operating range -40~130℃,-50~150℃ — check it against the installation environment.

Technical questions