NYDE plug-in tuning fork resonance density meter for online liquid density measurement in pipelines and tanks. Outputs 4-20 mA or RS485 Modbus RTU.
Medium temperature range-50℃~+150℃
Operating Temperature-40~130℃,-50~150℃
Calibration range0 – 2.5 g /cc (0 – 2500 kg/m3),0~100.0%
Fluid viscosity range0–600 cP
Measuring Range0 – 2.5 g /cc (0 – 2500 kg/m3),0~100.0%
Accuracy± 0.002 G /cc (± 2 Kg/m3) ,±0.5%
Product overview
Overview. The Nuoying NYDE is a plug-in tuning fork resonance density meter for online measurement of liquid density. It is installed in pipelines and in open or closed tanks, and the density of the medium is determined directly from the vibration frequency of the tuning fork immersed in it. Main characteristics — Measuring range is 0 to 2.5 g/cc (0 to 2500 kg/m3) and 0 to 100.0%. Accuracy is ±0.002 g/cc (±2 kg/m3) or ±0.5%, and repeatability is ±0.001 g/cc (±0.2 kg/m3) or ±0.1%. Working pressure reaches 4 MPa and the fluid viscosity range is 0 to 600 cP. The sensor includes a digital temperature sensor providing temperature compensation. Interfaces and connectivity — Signal output is available as 4-20 mA analog, 0-1000 Hz frequency or RS485 Modbus RTU. Power and environment — Power supply 24 VDC, 50 mA or more. Operating temperature -40 to 130 °C, medium temperature -50 to 150 °C, protection level IP67. The fork body is coated with standard PTFE or PFA and the shell is aluminum alloy. Process connection DIN 50 PN16 or DIN 50 PN40, with retractable T-shaped side-opening installation. Typical uses — Process control on products where density is the basic parameter, interface detection in multi-product pipelines, end-point monitoring of reactors and interface detection in separators, notably in petrochemical, food, pharmaceutical and mineral processing industries. Limitations — Not suitable for unstable flow, pipelines smaller than DN100 or flocculent solutions such as pulp. The RS485 Modbus RTU output allows integration into a PLC or supervisory system.
Shortcoming — Not applicable to:; Unstable flow rate; The main pipe diameter is less than DN100 — 1.
Flocculent solution (such as pulp, etc.)
Signal Output
4-20 MA,0-1000Hz,RS485 Modbus RTU
Stress effect
Negligible
Temperature
-50-150℃
Temperature Coefficient
< 0.1 kg/m3/℃(±0.5%) After correction
Viscosity range — Max 600Cp
Maximum 100cP (up to 250cP in individual cases)
Working Pressure
4mpa
Integration
Points to check before using 16067439-00 in a design. They are derived from the recorded characteristics, not from the manufacturer's application circuits.
1Thermalrated operating range -40~130℃,-50~150℃ — check it against the installation environment.
Power and communication
Power supply
24VDC,≥ 50 mA
Check the exact pin assignment and the application circuit in the datasheet, or ask our experts.
Implementation checklist
Thermal : rated operating range -40~130℃,-50~150℃ — check it against the installation environment.
Applications and use cases
Architectures in which 16067439-00 can play a role, derived from its category. This is not a compatibility statement: check the specifications against your requirements.
A proprietary PLC locks the project into one vendor’s tools. Industrial controllers built on the Raspberry Pi Compute Module run Linux, Node-RED, Python or CODESYS on DIN rail, with I/O modules, an operator panel and a cellular router for remote access
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
Current productNuoying
16067439-00