18854175-00
24 VDC differential pressure transmitter for liquids and gases

- Operating Temperature Range
- -20~+100°C
- Measuring Range
- Range 3 0-1.3~7.5kPa
- Accuracy
- ±0.1% URL ±0.2% URL
- Ambient temperature
- -0~-100% relative humidity
24 VDC differential pressure transmitter for liquids and gases
The NY3051 from Nuoying is a differential pressure transmitter with 4-20 mA output and HART protocol, designed to measure the pressure of liquids, gases and air.
Overview. The NY3051 from Nuoying is a differential pressure transmitter with 4-20 mA output and HART protocol, for measuring the pressure of liquids, gases and air.
Main characteristics. Accuracy is ±0.1% URL, with stability of ±0.1 URL over six months. The measuring range is 0-1.3 to 7.5 kPa (range 3). The damping time constant is adjustable in 0.1-second increments, up to 16.0 seconds. Zero and range can be adjusted with the instrument buttons or with HART remote adjustment.
Interfaces and connectivity. 4-20 mA output with HART, allowing remote configuration and connection to a supervision system.
Power and environment. Power supply 24 VDC (12 VDC to 45 VDC). Operating temperature from -40 to +85 °C without LCD display, from -30 to +60 °C with LCD display. Medium temperature from -40 to +100 °C. Protection rating IP65.
Certifications and safety. SIL3 and CE certified, with explosion-proof certificate. Intrinsically safe Exia II CT6 and flameproof Exd II BT5 explosion-proof grades.
Typical uses. Differential pressure, level and flow measurement in liquid or gas installations, including hazardous areas.
No published question about this part yet. Questions are reviewed before publication.
Every characteristic recorded for 18854175-00, with where it comes from. Use the filters to find one quickly.
| Characteristic | Value |
|---|---|
| Supply voltage | 24VDC(12VDC~45VDC) Explosion-proof type:12~28VDC |
| Accuracy | ±0.1% URL ±0.2% URL |
| Ambient temperature | -0~-100% relative humidity |
| Certification | Explosion-proof certificate,SIL3,CE |
| Damping time constant | The time constant is adjustable, incremented by 0.1 seconds, from minimum to 16.0 seconds. |
| EMI/RFI effect | Between 20 to 1000MHz; field strength up to 30V / M; the output drift less than ± 0.1% range |
| Explosion-proof grade | Intrinsically safe: Exia II CT6 Flameproof: Exd II BT5 |
| Installation site effect | Maximum Zero drift is ± 0.25kPa; all zero drift can be corrected. |
| Load effect | No load is affected unless the supply voltage changes |
| Measurement medium | Liquid, Gas, Air |
| Measuring medium | liquid, gas |
| Measuring Range | Range 3 0-1.3~7.5kPa |
| Medium temperature | -40~+100°C |
| Model Number | NY3051 |
| Operating Temperature | -40~+85°C(without LCD display) -30~+60°C(with LCD display) |
| Operating Temperature Range | -20~+100°C |
| Output signal | 4-20mA/HART |
| Power supply | 24VDC(12VDC~45VDC) |
| Power supply effect | Less than 0.0059% / V of the output range |
| Protection | IP65 |
| Protection Grade | IP65 |
| Signal Output | 4~20mA 4~20mA with HART |
| Stability | ±0.1 URL in six months |
| Static pressure and over-pressure limit | Transmitter on any side plus 0 to 13.79MPa pressure will not cause damage. In the 0kPa to the transmitter range of the upper limit of the work to meet the performance requirements. |
| Storage Temperature | -40~+100°C(without LCD display) -40~+70°C(with LCD display) |
| Temperature impact | ±(0.2%URL+0.18%inspection range)/56°C |
| Vibration Effect | The vibration effect is ± 0.05% URL / g at 200 Hz in any axial direction. |
| Zero and range | Zero and range can be adjusted with the instrument range and zero button, or with the HART handhold remote adjustment. |
| Zero point positive and negative migration | When zero is moving, the minimum range must be larger than or equal to - URL, the maximum range must be less than or equal to + URL. The calibration range must be greater than or equal to the minimum range. |
No specification matches.
Last verification : 2026-11-02
Official documents and the technical data recorded for 18854175-00. For a missing document or a specific revision, our experts send it to you.
The NY3051 from Nuoying is a differential pressure transmitter with 4-20 mA output and HART protocol, designed to measure the pressure of liquids, gases and air.
| Parameter | Value |
|---|---|
| Supply voltage | 24VDC(12VDC~45VDC) Explosion-proof type:12~28VDC |
| Accuracy | ±0.1% URL ±0.2% URL |
| Ambient temperature | -0~-100% relative humidity |
| Certification | Explosion-proof certificate,SIL3,CE |
| Damping time constant | The time constant is adjustable, incremented by 0.1 seconds, from minimum to 16.0 seconds. |
| EMI/RFI effect | Between 20 to 1000MHz; field strength up to 30V / M; the output drift less than ± 0.1% range |
| Explosion-proof grade | Intrinsically safe: Exia II CT6 Flameproof: Exd II BT5 |
| Installation site effect | Maximum Zero drift is ± 0.25kPa; all zero drift can be corrected. |
| Load effect | No load is affected unless the supply voltage changes |
| Measurement medium | Liquid, Gas, Air |
| Measuring medium | liquid, gas |
| Measuring Range | Range 3 0-1.3~7.5kPa |
| Medium temperature | -40~+100°C |
| Model Number | NY3051 |
| Operating Temperature | -40~+85°C(without LCD display) -30~+60°C(with LCD display) |
| Operating Temperature Range | -20~+100°C |
| Output signal | 4-20mA/HART |
| Power supply | 24VDC(12VDC~45VDC) |
| Power supply effect | Less than 0.0059% / V of the output range |
| Protection | IP65 |
| Protection Grade | IP65 |
| Signal Output | 4~20mA 4~20mA with HART |
| Stability | ±0.1 URL in six months |
| Static pressure and over-pressure limit | Transmitter on any side plus 0 to 13.79MPa pressure will not cause damage. In the 0kPa to the transmitter range of the upper limit of the work to meet the performance requirements. |
| Storage Temperature | -40~+100°C(without LCD display) -40~+70°C(with LCD display) |
| Temperature impact | ±(0.2%URL+0.18%inspection range)/56°C |
| Vibration Effect | The vibration effect is ± 0.05% URL / g at 200 Hz in any axial direction. |
| Zero and range | Zero and range can be adjusted with the instrument range and zero button, or with the HART handhold remote adjustment. |
| Zero point positive and negative migration | When zero is moving, the minimum range must be larger than or equal to - URL, the maximum range must be less than or equal to + URL. The calibration range must be greater than or equal to the minimum range. |
Points to check before using 18854175-00 in a design. They are derived from the recorded characteristics, not from the manufacturer's application circuits.
| Supply voltage | 24VDC(12VDC~45VDC) Explosion-proof type:12~28VDC |
| Power supply | 24VDC(12VDC~45VDC) |
| Power supply effect | Less than 0.0059% / V of the output range |
Check the exact pin assignment and the application circuit in the datasheet, or ask our experts.
Answers to the questions that the recorded characteristics of 18854175-00 can answer. A question is not asked when nothing is recorded to answer it.
Yes — recorded under "Installation site effect": Maximum Zero drift is ± 0.25kPa; all zero drift can be corrected..
24VDC(12VDC~45VDC) Explosion-proof type:12~28VDC (source: Supply voltage).
-40~+85°C(without LCD display) -30~+60°C(with LCD display) (source: Operating Temperature).
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
24 VDC differential pressure transmitter for liquids and gases

Differential Pressure Insert Venturi Flow Meter 2.5MPa DN500 - DN2600

Pipe Type Differential pressure online density meter

Piezoresistive Differential Pressure Sensor

Describe your application and constraints in a request.
What is recorded about the regulatory status and the life of this part.
| Current status | Status not stated |
| Key dates | Not recorded |
| Manufacturer part number | 18854175-00 |
| Manufacturer | Nuoying |
Differential Pressure Sensors
Piezoresistive oil-filled differential pressure sensor · Ref. : MDM290
Price on request
Differential Pressure Sensors
Air differential pressure sensor with RS485 Modbus RTU output