NY-MFL-200 – Thermal insertion mass flow meter for ammonia gas, 316 stainless steel
Thermal insertion mass flow meter for ammonia gas, 316 stainless steel
- 2.5%
- Compact and Remote
- SS316
- Ammonia Gas
- Manufacturer part number
- 19458983-00
- Manufacturer
- Nuoying
- Accuracy
- 2.5%
- Certification
- Explosion-proof certificate
Thermal insertion mass flow meter for measuring ammonia gas flow, with 316 stainless steel sensor housing and 4-20 mA, pulse and RS485 outputs.
- Accuracy2.5%
- CertificationExplosion-proof certificate
- ConstructionCompact and Remote
- MaterialSS316
- MeasuringVarious gases(Except the acetylene)
- MediumAmmonia Gas
Product overview
Nuoying NY-MFL-200. This Nuoying thermal insertion mass flow meter measures the flow of ammonia gas and most gases except acetylene. It operates on the thermal dispersion principle using a constant differential temperature method.
Main characteristics. Accuracy of 2.5%. The meter displays mass flow, volume flow in standard condition, flow totalizer, date and time, working time and velocity. It comes with an explosion-proof certificate.
Construction. The sensor housing is 316 stainless steel, and compact or remote versions are available. Sensor types include standard insertion, hot-tapped insertion and flanged. Compatible pipe materials include carbon steel, stainless steel and plastic.
Interfaces and connectivity. 4-20 mA outputs with optoelectronic isolation and a maximum load of 500 Ω, a pulse output and an RS485 output with optoelectronic isolation. The alarm output is a normally open relay rated 10 A/220 V AC or 5 A/30 V DC.
Power and environment. Compact version at 24 VDC or 220 VAC, power consumption up to 18 W. Remote version at 220 VAC, power consumption up to 19 W. Sensor operating range from -40 °C to +220 °C, transmitter from -20 °C to +45 °C.
Typical uses. The 4-20 mA, pulse and RS485 outputs allow connection to PLCs or supervisory systems for monitoring gas flow rates.
Highlights
- Accuracy: 2.5%
- Alarm Output: Relay,Normally Open state,10A/220V/AC or 5A/30V/DC
- Certification: Explosion-proof certificate
- Construction: Compact and Remote
- Material: SS316
- Measuring: Various gases(Except the acetylene)
Technical questions
No published question about this part yet. Questions are reviewed before publication.
Complete specifications
Every characteristic recorded for 19458983-00, with where it comes from. Use the filters to find one quickly.
All specifications (17)
| Characteristic | Value |
|---|---|
| Accuracy | 2.5% |
| Alarm Output | Relay,Normally Open state,10A/220V/AC or 5A/30V/DC |
| Certification | Explosion-proof certificate |
| Construction | Compact and Remote |
| Display | Mass flow,Volume flow in standard condition,Flow totallzer,Date and Time,Working time,and Velocity,etc |
| Material | SS316 |
| Measuring | Various gases(Except the acetylene) |
| Medium | Ammonia Gas |
| Model Number | NY-MFL-200 |
| Output | 4-20mA (optoelectronic isoltion,maximum load 500Ω ),Pulse,RS485(optoelectronic isolation) |
| Pipe Material | Carbon steel,stainless steel,plastic,etc |
| Power supply | Compact type: 24VDC or 220VAC,Power consumption≤ 18W; Remote type: 220VAC,Power consumption≤ 19W |
| Sensor housing material | Stainless steel(316) |
| Sensor Type | Standard Insertion,Hot-tapped Insertion and Flanged |
| Temperature | -40C - +220 C |
| Type | Insertion:Flanged |
| Working temperature | Sensor:-40°C~+220°C; Transmitter:-20°C~+45°C |
No specification matches.
Last verification : 2026-11-02
Technical documentation
Official documents and the technical data recorded for 19458983-00. For a missing document or a specific revision, our experts send it to you.
Contents
Overview Datasheet extract Official documents1. Technical overview
Thermal insertion mass flow meter for measuring ammonia gas flow, with 316 stainless steel sensor housing and 4-20 mA, pulse and RS485 outputs.
2. Datasheet extract (recorded values)
| Parameter | Value |
|---|---|
| Accuracy | 2.5% |
| Alarm Output | Relay,Normally Open state,10A/220V/AC or 5A/30V/DC |
| Certification | Explosion-proof certificate |
| Construction | Compact and Remote |
| Display | Mass flow,Volume flow in standard condition,Flow totallzer,Date and Time,Working time,and Velocity,etc |
| Material | SS316 |
| Measuring | Various gases(Except the acetylene) |
| Medium | Ammonia Gas |
| Model Number | NY-MFL-200 |
| Output | 4-20mA (optoelectronic isoltion,maximum load 500Ω ),Pulse,RS485(optoelectronic isolation) |
| Pipe Material | Carbon steel,stainless steel,plastic,etc |
| Power supply | Compact type: 24VDC or 220VAC,Power consumption≤ 18W; Remote type: 220VAC,Power consumption≤ 19W |
| Sensor housing material | Stainless steel(316) |
| Sensor Type | Standard Insertion,Hot-tapped Insertion and Flanged |
| Temperature | -40C - +220 C |
| Type | Insertion:Flanged |
| Working temperature | Sensor:-40°C~+220°C; Transmitter:-20°C~+45°C |
Technical FAQ
Answers to the questions that the recorded characteristics of 19458983-00 can answer. A question is not asked when nothing is recorded to answer it.
1Does it support RS-485?
Yes — recorded under "Output": 4-20mA (optoelectronic isoltion,maximum load 500Ω ),Pulse,RS485(optoelectronic isolation).
Compliance, lifecycle and traceability
What is recorded about the regulatory status and the life of this part.
Regulatory compliance
Lifecycle and product statusStatus not stated
- In production
- Not recommended for new designs
- End of life
- Obsolete
| Current status | Status not stated |
| Key dates | Not recorded |
Manufacturer references
| Manufacturer part number | 19458983-00 |
| Manufacturer | Nuoying |