NYXJ – Gas turbine vortex flow meter with pressure and temperature detection

Gas turbine vortex flow meter with pressure and temperature detection

Vortex Flow Meters

  • Custom design
  • 0.1~10m/s
  • 3W
  • 1.0%F.S-1.5%F.S
Manufacturer part number
30636660-00
Manufacturer
Nuoying
Measuring Range
Custom design
Velocity range
0.1~10m/s

The Nuoying NYXJ gas turbine vortex flow meter measures gas flow and integrates pressure and temperature detection with automatic compensation. It is intended for gas measurement in industry.

Product overview

Overview. The Nuoying NYXJ is a gas turbine vortex flow meter that integrates flow, temperature and pressure measurement. It automatically compensates for temperature, pressure and compression factor. According to the manufacturer, it is an instrument suited to gas measurement in the petroleum, chemical, electric power, metallurgy and other industries.

Main characteristics. The velocity range is 0.1 to 10 m/s and the accuracy 1.0% to 1.5% of full scale. Nominal diameters range from 15 to 200 mm, with a custom measuring range. The pressure rating is 4.0 MPa or less. Parameters are set through EEPROM technology, which keeps up to one year of historical data. The flow meter head rotates 270 degrees to ease installation.

Interfaces and connectivity. The converter can output a frequency pulse and a 4-20 mA analog signal, and has an RS485 interface. A multi-parameter alarm output is available, one of which can be selected by the user. The connection method is flange. Straight pipe requirements are 5 DN upstream and 3 DN downstream.

Power and environment. The meter is powered by 220 VAC with 15% tolerance or 24 VDC with ripple of 5% or less, or by an internal 3.6 V battery. Power consumption is 3 W. Protection grade is IP65. Medium temperature is -20 °C to +80 °C and ambient temperature is -30 °C to +65 °C. The shell is stainless steel, with aluminum alloy as an option.

Typical uses. Gas flow measurement. The listed certifications are CE and the explosion-proof grades Exia II CT4 Ga and Exd II CT5 Gb, according to the certificate.

Integration. The RS485 output and the 4-20 mA and pulse outputs allow the meter to be integrated into a supervision system. Products can be customized to user requirements.

See all specifications

Highlights

  • Accuracy: 1.0%F.S-1.5%F.S
  • Ambient temperature: -30℃~/+65℃
  • Atmospheric pressure: 86KPa~106KPa
  • Certification: CE
  • Connection Method: Flange
  • Explosion-proof grade: Exia II CT4 Ga, Exd II CT5 Gb (see certificate for details)