NYDE – Modbus RTU tuning fork density meter, plug-in probe

Modbus RTU tuning fork density meter, plug-in probe

Modular DIN-Rail Remote I/O Modules

  • -50℃~+150℃
  • ±0.1% of reading
  • 4-20 mA,0-1000Hz
  • Digital sensor
Manufacturer part number
31280494-00
Manufacturer
Nuoying
Medium temperature range
-50℃~+150℃
Output accuracy (20℃)
±0.1% of reading

Plug-in tuning fork density meter for online measurement of liquid density in pipelines and tanks, with 4-20 mA output and Modbus RTU communication.

Product overview

Overview. The NYDE tuning fork density meter from manufacturer Nuoying is a plug-in probe for pipeline and tank installation, designed for real-time online measurement of liquid density. The principle relies on the vibration of a tuning fork immersed in the medium: the oscillation frequency, which depends on the density of the fluid, is detected by a piezoelectric element and amplified by the head electronics.

Main characteristics. Measuring range of 0.5 to 2.5 g/cc (500 to 2500 kg/m3), measurement accuracy of ±0.002 g/cc (±2 kg/m3) or ±0.5%, repeatability of ±0.001 g/cc (±0.2 kg/m3) or ±0.1%, and output accuracy of ±0.1% of reading at 20 ℃. A built-in temperature sensor provides temperature compensation. Working pressure reaches 207 bar.

Interfaces and connectivity. 4-20 mA analog output and 0-1000 Hz output, plus Modbus RTU digital communication for integration into a supervisory system or a PLC.

Power and environment. 24 VDC supply, minimum 50 mA. Protection level IP67. Medium temperature from -50 ℃ to +150 ℃. Aluminum alloy shell, wetted parts in 316L and 2205 stainless steel, standard PTFE or PFA fork coating. Process connection DIN 50 PN16 or DIN 50 PN40.

Typical uses. Process control where density is the basic parameter, quality control based on solid or concentration percentage, interface detection in multi-product pipelines, reactor end-point monitoring and interface detection in separators. Industries cited by the manufacturer: petrochemical, wine, food, pharmaceutical and mineral processing.

Certifications. CE, ATEX and SIL markings.

See all specifications

Highlights

  • Analog signal output: 4-20 mA,0-1000Hz
  • Built-in temperature sensor: Digital sensor
  • Calibration range: 0.5 – 2.5 g /cc (500 – 2500 kg/m3),0~100.0%
  • Certification: CE,ATEX,SIL
  • Fork body coating: Standard PTFE or PFA
  • Measurement Accuracy: ± 0.002 g /cc (± 2 kg/m3),±0.5%

Typical applications

Derived from the part category, not a compatibility statement.

Technical questions

Ask a question

No published question about this part yet. Questions are reviewed before publication.

Request a quote