32585616-00
Handheld ultrasonic flow meter and heat calculator

- Measuring Range
- 0~±10m/s
- Heat consumption calculation
- from 0.25K
- Measuring Accuracy
- ±1.0%
- Ambient temperature
- Class B -25℃~55℃
Handheld ultrasonic flow meter and heat calculator
Nuoying NYCL-100C handheld ultrasonic flow meter and thermal energy computer with PT100 sensor for heating pipelines.
Overview. The Nuoying NYCL-100C ultrasonic flow meter is a portable analyzer engineered for online diagnostics across heating pipe networks and industrial thermal installations.
Thermal Metering. Combining transit-time flow velocity measurement from 0~±10m/s (±1.0% accuracy) with a three-wire PT100 sensor, it calculates thermal energy consumption starting from 0.25K.
Interface. Providing an RS485 serial port with Modbus, 4-20mA output, OCT pulse output and relay output, it runs on AC85-264V or DC24V power. Ambient operating limits span -25℃~55℃.
No published question about this part yet. Questions are reviewed before publication.
Every characteristic recorded for 32585616-00, with where it comes from. Use the filters to find one quickly.
| Characteristic | Value |
|---|---|
| Ambient temperature | Class B -25℃~55℃ |
| Applicable Tubes | Carbon steel, stainless steel, cast iron, copper, PVC, aluminum, glass fiber reinforced plastic and other uniform quality and density of the pipe, allowing a lining straight |
| Certification | CE |
| Data interface | RS485 serial interface, can be upgraded through the PC computer to the flowmeter, support Modbus and other protocols |
| Direction of flow | Positive and negative bi-directional metering, and measurement of positive, negative and net cumulative flow heat |
| Heat consumption calculation | from 0.25K |
| heat unit | Gijor, kcal, BTU optional |
| Measurement media | Water, seawater, sewage, alcohol, various oils and other media that can conduct ultrasound in a single, uniform, stable liquid |
| Measurement Period | 500ms (2 times per second, 128 sets of data collected per cycle) |
| Measuring Accuracy | ±1.0% |
| Measuring Principle | Ultrasonic time difference type principle |
| Measuring Range | 0~±10m/s |
| Media turbidity | ≤ 20,000ppm and small bubble content |
| Model Number | NYCL-100C |
| Pipe Section | The sensor installation point should preferably meet: 10D upstream, 5D downstream, 30D from the pump outlet |
| Power supply method | AC85-264V or DC24V |
| Signal Output | 4-20mA output, OCT pulse output, relay output. |
| Temperature sensor | PT100 three-wire platinum resistance |
No specification matches.
Last verification : 2026-11-02
Official documents and the technical data recorded for 32585616-00. For a missing document or a specific revision, our experts send it to you.
Nuoying NYCL-100C handheld ultrasonic flow meter and thermal energy computer with PT100 sensor for heating pipelines.
| Parameter | Value |
|---|---|
| Ambient temperature | Class B -25℃~55℃ |
| Applicable Tubes | Carbon steel, stainless steel, cast iron, copper, PVC, aluminum, glass fiber reinforced plastic and other uniform quality and density of the pipe, allowing a lining straight |
| Certification | CE |
| Data interface | RS485 serial interface, can be upgraded through the PC computer to the flowmeter, support Modbus and other protocols |
| Direction of flow | Positive and negative bi-directional metering, and measurement of positive, negative and net cumulative flow heat |
| Heat consumption calculation | from 0.25K |
| heat unit | Gijor, kcal, BTU optional |
| Measurement media | Water, seawater, sewage, alcohol, various oils and other media that can conduct ultrasound in a single, uniform, stable liquid |
| Measurement Period | 500ms (2 times per second, 128 sets of data collected per cycle) |
| Measuring Accuracy | ±1.0% |
| Measuring Principle | Ultrasonic time difference type principle |
| Measuring Range | 0~±10m/s |
| Media turbidity | ≤ 20,000ppm and small bubble content |
| Model Number | NYCL-100C |
| Pipe Section | The sensor installation point should preferably meet: 10D upstream, 5D downstream, 30D from the pump outlet |
| Power supply method | AC85-264V or DC24V |
| Signal Output | 4-20mA output, OCT pulse output, relay output. |
| Temperature sensor | PT100 three-wire platinum resistance |
Answers to the questions that the recorded characteristics of 32585616-00 can answer. A question is not asked when nothing is recorded to answer it.
Yes — recorded under "Data interface": RS485 serial interface, can be upgraded through the PC computer to the flowmeter, support Modbus and other protocols.
Yes — recorded under "Data interface": RS485 serial interface, can be upgraded through the PC computer to the flowmeter, support Modbus and other protocols.
Yes — recorded under "Data interface": RS485 serial interface, can be upgraded through the PC computer to the flowmeter, support Modbus and other protocols.
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
Handheld ultrasonic flow meter and heat calculator

Light Weight Handheld Ultrasonic Flow Meter RS485 NYCL - 100A Type

NYCL - 100B Water Portable Ultrasonic Flowmeter Cold Heat Measurement

Wide Range Ratio Fixed Ultrasonic Flow Meter High Precision NYCL - 100G

Describe your application and constraints in a request.
What is recorded about the regulatory status and the life of this part.
| Current status | Status not stated |
| Key dates | Not recorded |
| Manufacturer part number | 32585616-00 |
| Manufacturer | Nuoying |
Ultrasonic Flow Meters
Portable ultrasonic flow meter with clamp-on transducers
Price on request
Ultrasonic Flow Meters
Non-contact ultrasonic flow meter for industrial pipelines
Price on request
Ultrasonic Flow Meters
Portable dual-channel transit-time ultrasonic flow meter
Price on request
Ultrasonic Flow Meters
High-temperature ultrasonic flow transducer · Ref. : US0081
Price on request
With your consent, we use Google cookies to measure the site’s audience and our advertising. Your quote basket and comparison stay in your browser either way. Details