34382454-00
Flanged liquid level ultrasonic transmitter, 0 to 20 m, 4-20 mA output

- Electrical Interface
- M20×1.5,½ "NPT
- Certification
- CE
- Display Mode
- Liquid level, distance (air height )
- Levels of Protection
- IP65、IP67、IP68(selectable)
Flanged liquid level ultrasonic transmitter, 0 to 20 m, 4-20 mA output
The Nuoying NYCSUL-502 is a non-contact flanged ultrasonic level transmitter for measuring and controlling liquid levels, with a 0 to 20 m range in integrated version and 0 to 40 m in split version.
Overview. The Nuoying NYCSUL-502 is a flanged ultrasonic liquid level transmitter. It is mounted on top of the vessel and measures the level from the return time of ultrasonic pulses reflected by the liquid surface. The sensor operates without contact with the product.
Main characteristics. Measurement accuracy is below 0.25% for ranges under 20 m and below 0.5% for ranges over 20 m. The measuring range is 0 to 20 m in integrated version and 0 to 40 m in split version. The permissible process pressure is -0.1 to 0.1 MPa (atmospheric pressure). The sensor offers upper and lower limit setting with set-point output. It displays liquid level or distance (air height).
Interfaces and connectivity. The output signal is selectable among 4-20 mA, HART, RS485 or Modbus. Electrical connection is M20×1.5 or 1/2" NPT. The process connection is a flange.
Power and environment. Protection ratings are IP65, IP67 or IP68, selectable. Antenna materials are PP, PVC or 304. Explosion-proof certification is Exia II CT6 Ga and Exd II CT6 Gb, see the certificate for details. The sensor is CE certified.
Typical uses. The sensor suits liquids without stirring, foam or volatilization. Thanks to its RS485 and Modbus outputs, it can be connected to a PLC or a supervision system.
Integration. The sensor is available in integrated or split probe configuration.
No published question about this part yet. Questions are reviewed before publication.
Every characteristic recorded for 34382454-00, with where it comes from. Use the filters to find one quickly.
| Characteristic | Value |
|---|---|
| Accuracy Of Measurement: | <0.25% (range < 20 m), <0.5% (range > 20 m) |
| Certification | CE |
| Display Mode | Liquid level, distance (air height ) |
| Electrical Interface | M20×1.5,½ "NPT |
| Explosion-proof grade | Exia II CT6 Ga, Exd II CT6 Gb(see certificate for details) |
| Levels of Protection | IP65、IP67、IP68(selectable) |
| Measuring Range | 0~ 20M ( integrated ), 0~40m ( separate ), |
| Model Number | NYCSUL-502 |
| Process Connection | Flange |
| Process pressure | -0.1 ~ 0.1 MPa, (atmospheric pressure) |
| Product Models: | NYCSUL-502 |
| Protection Class | IP65, IP67, IP68 (optional) |
| Protection Grade | IP65, IP67, IP68(Optional) |
| Set output | Upper Limit Setting And Lower Limit Setting |
| Set the output | Upper limit setting, lower limit setting |
| Signal Output | 4... 20mA/ HART/ RS485/Modbus... |
| T ypical application | Liquid (no stirring, foam, volatilization, etc.) |
| The antenna material | PP, PVC, 304 |
| The probe type | Integrated, split |
| The process temperature | 3M, 20M |
No specification matches.
Last verification : 2026-11-02
Official documents and the technical data recorded for 34382454-00. For a missing document or a specific revision, our experts send it to you.
The Nuoying NYCSUL-502 is a non-contact flanged ultrasonic level transmitter for measuring and controlling liquid levels, with a 0 to 20 m range in integrated version and 0 to 40 m in split version.
| Parameter | Value |
|---|---|
| Accuracy Of Measurement: | <0.25% (range < 20 m), <0.5% (range > 20 m) |
| Certification | CE |
| Display Mode | Liquid level, distance (air height ) |
| Electrical Interface | M20×1.5,½ "NPT |
| Explosion-proof grade | Exia II CT6 Ga, Exd II CT6 Gb(see certificate for details) |
| Levels of Protection | IP65、IP67、IP68(selectable) |
| Measuring Range | 0~ 20M ( integrated ), 0~40m ( separate ), |
| Model Number | NYCSUL-502 |
| Process Connection | Flange |
| Process pressure | -0.1 ~ 0.1 MPa, (atmospheric pressure) |
| Product Models: | NYCSUL-502 |
| Protection Class | IP65, IP67, IP68 (optional) |
| Protection Grade | IP65, IP67, IP68(Optional) |
| Set output | Upper Limit Setting And Lower Limit Setting |
| Set the output | Upper limit setting, lower limit setting |
| Signal Output | 4... 20mA/ HART/ RS485/Modbus... |
| T ypical application | Liquid (no stirring, foam, volatilization, etc.) |
| The antenna material | PP, PVC, 304 |
| The probe type | Integrated, split |
| The process temperature | 3M, 20M |
Answers to the questions that the recorded characteristics of 34382454-00 can answer. A question is not asked when nothing is recorded to answer it.
Yes — recorded under "Signal Output": 4... 20mA/ HART/ RS485/Modbus....
Yes — recorded under "Signal Output": 4... 20mA/ HART/ RS485/Modbus....
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
Flanged liquid level ultrasonic transmitter, 0 to 20 m, 4-20 mA output

Stainless Steel RF Admittance Level Transmitter Rod Type For Solid Particle

Adjustable Soft Rope RF Admittance Level Sensor High Temperature Insulation

High Temperature Flap Magnetic Level Meter Oil Level Sensor Indicator Gauge

Describe your application and constraints in a request.
What is recorded about the regulatory status and the life of this part.
| Current status | Status not stated |
| Key dates | Not recorded |
| Manufacturer part number | 34382454-00 |
| Manufacturer | Nuoying |
Level Transmitters
Submersible liquid level sensor, 0-5 m range, 0.5-4.5 V output
Price on request
Level Transmitters
60 GHz Radar Level Sensor with RS485 MODBUS RTU Output
Price on request
Level Transmitters
Deep-water level transmitter with 4-20 mA output · Ref. : MPM426WS
Price on request
Level Transmitters
Industrial LoRaWAN ultrasonic level sensor
Price on request
With your consent, we use Google cookies to measure the site’s audience and our advertising. Your quote basket and comparison stay in your browser either way. Details