34538850-00
Open channel digital ultrasonic flow meter with PTFE antenna

- Measuring Range
- 35m,40m,80m
- Sense Range
- 3m; 5m; 8m; 10m; 12m; 15m; 20m; 25m; 30m
- Consumption
- <8W
- Accuracy
- ±0.3%F.S
Open channel digital ultrasonic flow meter with PTFE antenna
Antennas, RF Interconnect & Electromagnetic Components
NYRD808 digital open channel ultrasonic flow meter for liquids and solids, with PTFE antenna, used to measure flow and level in channels, weirs and flumes.
Overview. The NYRD808 ultrasonic flow meter from Nuoying is a digital open channel flow meter made of a host unit with LCD display and 16-key keypad, and an ultrasonic transducer to be mounted directly above the surface to be measured. It is designed for liquids, dust and solids.
Main characteristics. Accuracy of ±0.3% F.S, measurement accuracy of 0.05% to 0.1% F.S, resolution of 1 mm and blind area of 0.3 m to 1.5 m. Measuring range is 35 m, 40 m or 80 m depending on version, with sense ranges from 3 m to 30 m.
Interfaces and connectivity. 4-20 mA output as standard, plus 0-20 mA, 1-5 V, 0-5 V, 0-10 V, 1-10 V, RS485 and HART outputs, and 4 relays (contact capacity AC 5 A 250 V and DC 10 A 120 V).
Power and environment. Consumption below 8 W, protection degree IP53 for the instrument and IP65 for the sensor (optional), operating under normal temperature and normal pressure. 10 m sensor cable optional.
Typical uses. Open channel flow measurement over thin plate right-angle weirs, triangular weirs and Parshall flumes, in wastewater treatment, irrigation, sedimentation pools and coal washing processes. The RS485 output and HART protocol allow integration into a supervision system.
Integration. The sensor must be mounted directly above the measured surface. Certified CE, ExiaⅡCT6 Ga and ExdⅡCT6 Gb. Available on quotation from Atlas Electronics.
No published question about this part yet. Questions are reviewed before publication.
Every characteristic recorded for 34538850-00, with where it comes from. Use the filters to find one quickly.
| Characteristic | Value |
|---|---|
| Accuracy | ±0.3%F.S |
| Accuracy Of Measurement: | 0.05%~0.1%F.S |
| Antenna Form | Bar Type, Water Drop Type |
| Antenna Material | PTFE、304、316 |
| Application | Liquids,dust,solids |
| Blind area | <0.3m-1.5m |
| Certification | CE/ExiaⅡCT6 Ga,ExdⅡCT6 Gb |
| Consumption | <8W |
| Display | LCD |
| Dsiplay Screen Dimension | 240mm×184mm×110mm |
| Installation size | G1 1/2(3m); M60x2 (5-15m); M30X1.5 (20-30m) |
| Item No. | NYRD808 |
| Keyboard | 16 key |
| Material | ABS |
| Measuring Range | 35m,40m,80m |
| Model Number | NYRD808 |
| Operating surroundings | normal temperature, normal pressure |
| Output | 4~20mA(standard); 0~20mA; 1~5V; 0~5V; 0-10V; 1-10V; RS485; HART; 4 relays (Contact capacity AC:5A 250V DC:10A 120V) |
| Protection degree | IP53 for instrument; IP65 for sensor (optional) |
| Resolution | 1mm |
| Sense Range | 3m; 5m; 8m; 10m; 12m; 15m; 20m; 25m; 30m |
| Sensor Cable | 10m (optional) |
| Sensor size | Dimension size as bellow pictures; Φ 41×100×Φ 30 (for range:1 m); Φ 55mm×119mm×G1 1/2 (for range:3 m); Φ 74mm×135mm×M60 (for range:3~15 m)' Φ 109mm×200mm×M30 (for range: 16~35 m) |
No specification matches.
Last verification : 2026-11-02
Official documents and the technical data recorded for 34538850-00. For a missing document or a specific revision, our experts send it to you.
NYRD808 digital open channel ultrasonic flow meter for liquids and solids, with PTFE antenna, used to measure flow and level in channels, weirs and flumes.
| Parameter | Value |
|---|---|
| Accuracy | ±0.3%F.S |
| Accuracy Of Measurement: | 0.05%~0.1%F.S |
| Antenna Form | Bar Type, Water Drop Type |
| Antenna Material | PTFE、304、316 |
| Application | Liquids,dust,solids |
| Blind area | <0.3m-1.5m |
| Certification | CE/ExiaⅡCT6 Ga,ExdⅡCT6 Gb |
| Consumption | <8W |
| Display | LCD |
| Dsiplay Screen Dimension | 240mm×184mm×110mm |
| Installation size | G1 1/2(3m); M60x2 (5-15m); M30X1.5 (20-30m) |
| Item No. | NYRD808 |
| Keyboard | 16 key |
| Material | ABS |
| Measuring Range | 35m,40m,80m |
| Model Number | NYRD808 |
| Operating surroundings | normal temperature, normal pressure |
| Output | 4~20mA(standard); 0~20mA; 1~5V; 0~5V; 0-10V; 1-10V; RS485; HART; 4 relays (Contact capacity AC:5A 250V DC:10A 120V) |
| Protection degree | IP53 for instrument; IP65 for sensor (optional) |
| Resolution | 1mm |
| Sense Range | 3m; 5m; 8m; 10m; 12m; 15m; 20m; 25m; 30m |
| Sensor Cable | 10m (optional) |
| Sensor size | Dimension size as bellow pictures; Φ 41×100×Φ 30 (for range:1 m); Φ 55mm×119mm×G1 1/2 (for range:3 m); Φ 74mm×135mm×M60 (for range:3~15 m)' Φ 109mm×200mm×M30 (for range: 16~35 m) |
Answers to the questions that the recorded characteristics of 34538850-00 can answer. A question is not asked when nothing is recorded to answer it.
Yes — recorded under "Output": 4~20mA(standard); 0~20mA; 1~5V; 0~5V; 0-10V; 1-10V; RS485; HART; 4 relays (Contact capacity AC:5A 250V DC:10A 120V).
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
Open channel digital ultrasonic flow meter with PTFE antenna

4G Antenna Kit for LTE Cat 4 EC25 mini-PCIe

Long Range Indoor Antenna Kit; 860-930MHz; 3dBi; 295mm

Antenna QuSector Nf

Describe your application and constraints in a request.
What is recorded about the regulatory status and the life of this part.
| Current status | Status not stated |
| Key dates | Not recorded |
| Manufacturer part number | 34538850-00 |
| Manufacturer | Nuoying |
Antennas, RF Interconnect & Electromagnetic Components
Serial to Wi-Fi converter for RS232, RS422 and RS485 · Ref. : CSW-H85K2
Price on request
Antennas, RF Interconnect & Electromagnetic Components
Digital TV tuner for Android phones and tablets
Price on request
Antennas, RF Interconnect & Electromagnetic Components
Outdoor 2.4 GHz and 5 GHz WiFi panel antenna
Price on request
Antennas, RF Interconnect & Electromagnetic Components
Active GPS antenna with low noise amplifier
Price on request
With your consent, we use Google cookies to measure the site’s audience and our advertising. Your quote basket and comparison stay in your browser either way. Details