35649627-00
Flange ultrasonic level gauge, high transmission power

- Electrical Interface
- M20×1.5,½ "NPT
- Certification
- CE
- Display Mode
- Liquid level, distance (air height )
- Levels of Protection
- IP65、IP67、IP68(optional)
Flange ultrasonic level gauge, high transmission power
The NYCSUL-502 flange ultrasonic level gauge measures liquid level from the top of a tank without contact with the product. It suits liquids without stirring, foam or volatilization.
NYCSUL-502 ultrasonic level gauge. The NYCSUL-502 from Nuoying is a flange-mounted ultrasonic level transmitter for liquid level measurement. It is mounted on top of the container and emits an ultrasonic pulse toward the product surface; the echo return time, combined with the known speed of sound, gives the level.
Main characteristics. The gauge uses a small-angle ultrasonic probe with large transmission power and high sensitivity. Measurement accuracy is below 0.25% for ranges under 20 m and below 0.5% for ranges above 20 m. The measuring range is 0 to 20 m in the integrated version and 0 to 40 m in the separate version. Upper and lower limits and alarm can be set at any point, allowing continuous liquid measurement and level control.
Interfaces and connectivity. The signal output is 4-20 mA, with HART, RS485 and Modbus protocols. Electrical connection is M20×1.5 or 1/2 NPT. The process connection is a flange. Antenna materials available are PP, PVC and 304 stainless steel.
Power and environment. The gauge is rated IP65, IP67 and IP68 (optional). It is CE certified and carries explosion-proof rating Exia II CT6 Ga, Exd II CT6 Gb (see certificate for details). Permissible process pressure is -0.1 to 0.1 MPa, i.e. atmospheric pressure.
Typical uses. Level measurement and control of liquids without stirring, foam or volatilization. The RS485 output with Modbus allows connection to a PLC or supervisory system. Available on quotation from Atlas Electronics.
No published question about this part yet. Questions are reviewed before publication.
Every characteristic recorded for 35649627-00, with where it comes from. Use the filters to find one quickly.
| Characteristic | Value |
|---|---|
| Accuracy Of Measurement: | <0.25% (range < 20 m), <0.5% (range > 20 m) |
| Certification | CE |
| Display Mode | Liquid level, distance (air height ) |
| Electrical Interface | M20×1.5,½ "NPT |
| Explosion-proof grade | Exia II CT6 Ga, Exd II CT6 Gb(see certificate for details) |
| Levels of Protection | IP65、IP67、IP68(optional) |
| Measuring Range | 0~ 20M ( integrated ), 0~40m ( separate ), |
| Model Number | NYCSUL-502 |
| Process Connection | Flange |
| Process pressure | -0.1 ~ 0.1 MPa, (atmospheric pressure) |
| Product Models: | NYCSUL-502 |
| Protection Class | IP65, IP67, IP68 (optional) |
| Protection Grade | IP65, IP67, IP68(Optional) |
| Set output | Upper And Lower Limit Setting |
| Set the output | Upper limit setting, lower limit setting |
| Signal Output | 4... 20mA/ HART/ RS485/Modbus... |
| T ypical application | Liquid (no stirring, foam, volatilization, etc.) |
| The antenna material | PP, PVC, 304 |
| The probe type | Integrated, split |
| The process temperature | 3M, 20M |
No specification matches.
Last verification : 2026-11-02
Official documents and the technical data recorded for 35649627-00. For a missing document or a specific revision, our experts send it to you.
The NYCSUL-502 flange ultrasonic level gauge measures liquid level from the top of a tank without contact with the product. It suits liquids without stirring, foam or volatilization.
| Parameter | Value |
|---|---|
| Accuracy Of Measurement: | <0.25% (range < 20 m), <0.5% (range > 20 m) |
| Certification | CE |
| Display Mode | Liquid level, distance (air height ) |
| Electrical Interface | M20×1.5,½ "NPT |
| Explosion-proof grade | Exia II CT6 Ga, Exd II CT6 Gb(see certificate for details) |
| Levels of Protection | IP65、IP67、IP68(optional) |
| Measuring Range | 0~ 20M ( integrated ), 0~40m ( separate ), |
| Model Number | NYCSUL-502 |
| Process Connection | Flange |
| Process pressure | -0.1 ~ 0.1 MPa, (atmospheric pressure) |
| Product Models: | NYCSUL-502 |
| Protection Class | IP65, IP67, IP68 (optional) |
| Protection Grade | IP65, IP67, IP68(Optional) |
| Set output | Upper And Lower Limit Setting |
| Set the output | Upper limit setting, lower limit setting |
| Signal Output | 4... 20mA/ HART/ RS485/Modbus... |
| T ypical application | Liquid (no stirring, foam, volatilization, etc.) |
| The antenna material | PP, PVC, 304 |
| The probe type | Integrated, split |
| The process temperature | 3M, 20M |
Answers to the questions that the recorded characteristics of 35649627-00 can answer. A question is not asked when nothing is recorded to answer it.
Yes — recorded under "Signal Output": 4... 20mA/ HART/ RS485/Modbus....
Yes — recorded under "Signal Output": 4... 20mA/ HART/ RS485/Modbus....
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
Flange ultrasonic level gauge, high transmission power

Stainless Steel RF Admittance Level Transmitter Rod Type For Solid Particle

Adjustable Soft Rope RF Admittance Level Sensor High Temperature Insulation

High Temperature Flap Magnetic Level Meter Oil Level Sensor Indicator Gauge

Describe your application and constraints in a request.
What is recorded about the regulatory status and the life of this part.
| Current status | Status not stated |
| Key dates | Not recorded |
| Manufacturer part number | 35649627-00 |
| Manufacturer | Nuoying |
Level Transmitters
Submersible liquid level sensor, 0-5 m range, 0.5-4.5 V output
Price on request
Level Transmitters
60 GHz Radar Level Sensor with RS485 MODBUS RTU Output
Price on request
Level Transmitters
Deep-water level transmitter with 4-20 mA output · Ref. : MPM426WS
Price on request
Level Transmitters
Industrial LoRaWAN ultrasonic level sensor
Price on request