50066760-00
Liquid and Powder RF Admittance Level Sensor

- Operating Temperature
- -184~+260C
- Bar Material:
- 304+PTFE (optional)
- Certification
- CE, SIL, ATEX
- Customized support
- OEM, ODM
Liquid and Powder RF Admittance Level Sensor
RF admittance level switch for position control of liquids, powders, particles and solids, with DPDT relay output, 4-20 mA and RS485 Modbus RTU signal outputs.
Overview. The Nuoying NYSP-L862 is a radio frequency (RF) admittance level switch designed for level control of liquids, powders, particles and solid materials.
Main characteristics. 500 mm probe length, customizable as required, with 304 and PTFE bar material (optional) and 316L, stainless steel or Hastelloy joint materials. Operating temperature from -184 to +260 °C and process pressure from 0 to 2.0 MPa.
Interfaces and connectivity. Signal output 4 to 20 mA, 0 to 1000 Hz and RS485 Modbus RTU. Double pole, double throw (DPDT) relay output, 5 A, 24 VDC or 5 A, 220 VAC.
Power and environment. Power supply 24 VDC or 220 VAC (optional). Protection rating IP67 and explosion-proof Ex ia CT6 (optional). Thread connection, flange optional.
Typical uses. Level and position control of liquids, powders, particles and solids. The RS485 Modbus RTU output allows integration into a supervision system or a compatible PLC.
Certifications. CE, SIL and ATEX. Manufactured in Xi'an, Shaanxi, China, with OEM and ODM customization support.
No published question about this part yet. Questions are reviewed before publication.
Every characteristic recorded for 50066760-00, with where it comes from. Use the filters to find one quickly.
| Characteristic | Value |
|---|---|
| Applications | Liquid, Powder, Particle, Solid Position Control |
| Bar Material: | 304+PTFE (optional) |
| Certification | CE, SIL, ATEX |
| Customized support | OEM, ODM |
| Grade: | Industrial |
| Joint Material | 316L, stainless steel, Hastelloy |
| Model Number | NYSP-L862 |
| Operating Temperature | -184~+260C |
| Operation Temperature | -184~+260℃ |
| Output relay | Double Pole, Double Throw (DPDT) Output,5A,24VDC Or5A,220VAC |
| Power supply | 24VDC, 220VAC (optional) |
| Probe length | 500mm (customizable As Required) |
| Procedure Linkage: | Thread, Flange (optional) |
| Process Connection | Thread |
| Process pressure | 0~2.0MPa |
| Protection/explosion Class: | IP67/ExialCT6 (optional) |
| Signal Output | 4~20 MA,0~1000Hz,RS485 Modbus RTU |
| Typical application | Liquid, powder, particle, solid level control |
| Working Pressure | 0~2.0MPa |
No specification matches.
Last verification : 2026-11-02
Official documents and the technical data recorded for 50066760-00. For a missing document or a specific revision, our experts send it to you.
RF admittance level switch for position control of liquids, powders, particles and solids, with DPDT relay output, 4-20 mA and RS485 Modbus RTU signal outputs.
| Parameter | Value |
|---|---|
| Applications | Liquid, Powder, Particle, Solid Position Control |
| Bar Material: | 304+PTFE (optional) |
| Certification | CE, SIL, ATEX |
| Customized support | OEM, ODM |
| Grade: | Industrial |
| Joint Material | 316L, stainless steel, Hastelloy |
| Model Number | NYSP-L862 |
| Operating Temperature | -184~+260C |
| Operation Temperature | -184~+260℃ |
| Output relay | Double Pole, Double Throw (DPDT) Output,5A,24VDC Or5A,220VAC |
| Power supply | 24VDC, 220VAC (optional) |
| Probe length | 500mm (customizable As Required) |
| Procedure Linkage: | Thread, Flange (optional) |
| Process Connection | Thread |
| Process pressure | 0~2.0MPa |
| Protection/explosion Class: | IP67/ExialCT6 (optional) |
| Signal Output | 4~20 MA,0~1000Hz,RS485 Modbus RTU |
| Typical application | Liquid, powder, particle, solid level control |
| Working Pressure | 0~2.0MPa |
Points to check before using 50066760-00 in a design. They are derived from the recorded characteristics, not from the manufacturer's application circuits.
| Power supply | 24VDC, 220VAC (optional) |
Check the exact pin assignment and the application circuit in the datasheet, or ask our experts.
Answers to the questions that the recorded characteristics of 50066760-00 can answer. A question is not asked when nothing is recorded to answer it.
Yes — recorded under "Signal Output": 4~20 MA,0~1000Hz,RS485 Modbus RTU.
Yes — recorded under "Signal Output": 4~20 MA,0~1000Hz,RS485 Modbus RTU.
-184~+260C (source: Operating Temperature).
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
Liquid and Powder RF Admittance Level Sensor

NUOYING Liquid Powder Material Level Sensor NYSP-L861 Rf Admittance Switch

Rf Admittance Capacitance Level Sensor Level Transmitter Capacitive Level Switch

4-20mA NYCSUL-503 Ultrasonic Water Liquid Level Meter Sensor Non Contact Ultrasonic Level Sensor Transmitt

Describe your application and constraints in a request.
What is recorded about the regulatory status and the life of this part.
| Current status | Status not stated |
| Key dates | Not recorded |
| Manufacturer part number | 50066760-00 |
| Manufacturer | Nuoying |
Level Transmitters
Submersible liquid level sensor, 0-5 m range, 0.5-4.5 V output
Price on request
Level Transmitters
60 GHz Radar Level Sensor with RS485 MODBUS RTU Output
Price on request
Level Transmitters
Deep-water level transmitter with 4-20 mA output · Ref. : MPM426WS
Price on request
Level Transmitters
Industrial LoRaWAN ultrasonic level sensor
Price on request
With your consent, we use Google cookies to measure the site’s audience and our advertising. Your quote basket and comparison stay in your browser either way. Details