| Ambient Humidity | Operating: 35% to 85% (no condensation), Storage: 35% to 95% |
| Ambient temperature | Operating: -10 to 55°C (no icing), Storage: -30 to 70°C |
| Appearance — Cable length — Specifications | Order code |
| Appearance — Output | Order code |
| Appearance — Specifications — Application — Remarks | Order code |
| Appearance — Type — Remarks | Order code |
| Applicable Standards | IEC 61496-1, EN 61496-1 UL 61496-1, Type 4 ESPE (Electro-Sensitive Protective Equipment); IEC 61496-2, CLC/TS 61496-2, UL 61496-2, Type 4 AOPD (Active Opto-electronic Protective Devices); IEC 61508-1 to -3, EN 61508-1 to -3 SIL3; IEC 13849-1: 2006, EN ISO 13849-1: 2008 (PLe, Cat.4); UL 508, UL 1998, CAN/CSA C22.2 No.14, CAN/CSA C22.2 No.0.8 |
| Application — Detection capability — Beam gap — Operating range — Protective height (mm) | Order code |
| Auxiliary output 1; (Non-safety output) | One PNP transistor output, load current 300 mA max., residual voltage 2 V max. (except for voltage drop due to cable extension),; leak current 1 mA max. |
| Auxiliary output 2; (Non-safety output. Function for Basic System.) | One PNP transistor output, load current 50 mA max., residual voltage 2 V max. (except for voltage drop due to cable extension),; leak current 1 mA max. |
| Beam gap (P) — 9 mm | 25 mm |
| Condition — 1 set — 2 sets — 3 sets | 4 sets |
| Connection Method | Connector method (M12, 8-pin) |
| Current consumption; (no load) — Emitter | To 50 beams: 76 mA max., 51 to 100 beams: 106 mA max., 101 to 150 beams: 130 mA max.,; 151 to 180 beams: 153 mA max., 201 to 234 beams: 165 mA max. |
| Current consumption; (no load) — Receiver | To 50 beams: 68 mA max., 51 to 100 beams: 90 mA max., 101 to 150 beams: 111 mA max.,; 151 to 180 beams: 128 mA max., 201 to 234 beams: 142 mA max. |
| Degree of protection | IP65 (IEC 60529) |
| Detection capability — Opaque objects 14 mm in diameter | Opaque objects 30 mm in diameter |
| Effective aperture angle (EAA) | Based on IEC 61496-2.Within±2.5° for both emitter and receiver when the detection distance is 3 m or over |
| External indicator output; (Non-safety output) | Available indicators; Incandescent lamp : 24 VDC, 3 to 7 W; LED lamp: Load current 10 mA to 300 mA max., leak current 1 mA max.; (To use an external indicator, an F39-JJ3N universal indicator cable or an F39-A01P-PAC dedicated external indicator kit is required.) |
| Finger protection — Dia. 14 mm — 9 mm — 0.2 to 9 m — 245 to 1,631 | F3SJ-A ____ P14 |
| Hand/arm protection — Dia. 30 mm — 25 mm — 0.2 to 7 m — 1,745 to 2,495 | F3SJ-A ____ P30 |
| Hand/arm protection — Dia. 30 mm — 25 mm — 0.2 to 9 m — 245 to 1,620 | F3SJ-A ____ P30 |
| Indicator — Emitter | Light intensity level indicators (green LED × 2, orange LED × 3): ON based on the light intensity; Error mode indicators (red LED × 3): Blink to indicate error details; Power indicator (green LED × 1): ON while power is on; Interlock indicator (yellow LED × 1): ON while under interlock, blinks at lockout.; External device monitoring indicator (muting input 1 indicator), Blanking/test indicator (muting input 2 indicator) (green LED × 2):; ON/flash according to function |
| Indicator — Receiver | Light intensity level indicators (green LED × 2, orange LED × 3): ON based on the light intensity; Error mode indicators (red LED × 3): Blink to indicate error details; OFF output indicator (red LED × 1): ON when safety output is OFF, blinks at lockout.; ON output indicator (green LED × 1): ON while safety output is ON; Muting error indicator, Blanking/test indicator (green LED × 2): ON/flash according to function |
| Input Voltage | Test input, interlock selection input, reset input, and muting input are all; ON voltage: 9 to 24 V (Vs) (sink current: 3 mA max.), OFF voltage: 0 to 1.5 V, or open; External device monitoring input; ON voltage: 9 to 24 V (Vs) (sink current: 5 mA max.), OFF voltage: 0 to 1.5 V, or open |
| Insulation Resistance | 20 MΩ min. (at 500 VDC) |
| Laser pointer for F3SJ | F39-PTJ |
| Lens Diameter | Diameter 5 mm |
| Light source (emitted wavelength) | Infrared LED (870 nm) |
| Material | Casing (including metal parts on both ends): Aluminum, zinc die-cast; Cap: ABS resin, Optical cover: PMMA resin (acrylic), Cable: Oil resistant PVC |
| Mutual interference prevention function | Interference light prevention algorithm, sensing distance change function |
| Not using incandescent lamp — 100 m — 60 m — 45 m | 30 m |
| Number of beams (n) — 26 to 180 | 10 to 100 |
| Number of beams — Protective height (mm) 1 | Order code |
| Number of beams — Protective height (mm) 2 | Order code |
| Operating ambient light intensity | Incandescent lamp: receiving-surface light intensity of 3,000 lx max., Sunlight: receiving-surface light intensity of 10,000 lx max. |
| Operating Range | 0.2 to 9 m (protective height 1,640 mm max.), 0.2 to 7 m (protective height 1,655 mm min.); (Depending on the setting tool, the detection distance can be shortened to 0.5 m.) |
| Output operation mode — Emitter | Auxiliary output 2: Turns ON when the point of 30,000 operating hours is reached (Operation mode can be changed with the setting tool.); External indicator output 2 : ON when lock-out for a basic system (Operation mode can be changed with the setting tool.); ON when muting/override for a muting system (Operation mode can be changed with the setting tool.) |
| Output operation mode — Receiver | Safety output 1, 2: ON when receiving light; Auxiliary output 1: Inverse of safety output signals (Operation mode can be changed with the setting tool.); External indicator output 1 : Inverse of safety output signals for a basic system (Operation mode can be changed with the setting tool.), ON when muting/override for a muting system (Operation mode can be changed with the setting tool.) |
| Power supply voltage (Vs) | 24 VDC±20% (ripple p-p10% max.) |
| Protection circuit | Output short-circuit protection, and power supply reverse polarity protection |
| Protective height (PH) — 245 to 1,631 mm | 245 to 2,495 mm |
| Safety Category | Safety purpose of category 4, 3, 2, 1, or B |
| Safety outputs (OSSD) | Two PNP transistor outputs, load current 300 mA max., residual voltage 2 V max. (except for voltage drop due to cable extension),; allowable capacity load 2.2 μF, leak current 1 mA max.; (This can be different from traditional logic (ON/OFF) because safety circuit is used.) |
| Safety-related functions | Start interlock, restart interlock (Must be set with a setting tool when the muting function is used.); External device monitor; Muting (Lamp burnout detection, override function included. F39-CN6 key cap for muting is required.); Fixed blanking (must be set by a setting tool); Floating blanking (must be set by a setting tool) |
| Sensor Type | Type 4 safety light curtain |
| Series connection | Time division emission by series connection; Number of connections: up to 4 sets (F3SJ-A only) F3SJ-E, F3SJ-B and F3SJ-TS cannot be connected.; Total number of beams: up to 400 beams; Maximum cable length for 2 sets: no longer than 15 m |
| Setting tool connection | Connectable |
| Shock Resistance | Malfunction: 100 m/s2, 1,000 times each in X, Y, and Z directions |
| Startup waiting time | 2 s max. (2.2 s max. for series connection) |
| Test function | Self test (at power-ON and at power distribution); External test (emission stop function by test input) |
| Using incandescent lamp for auxiliary output 1 — 60 m — 45 m — 30 m | 20 m |
| Using incandescent lamp for auxiliary output and external indicator output — 45 m — 40 m — 30 m | 20 m |
| Using incandescent lamp for external indicator output 1 — 60 m — 45 m — 30 m | 20 m |
| Using incandescent lamp for external indicator output 2 — 40 m — 30 m — 25 m | 20 m |
| Vibration Resistance | Malfunction: 10 to 55 Hz, Multiple amplitude of 0.7 mm, 20 sweeps in X, Y, and Z directions |
| Weight (Packaged) | Calculate using the following expressions:; (1) For F3SJ-A ____ 14, weight (g) = (protective height) x 1.7 + α; (2) F3SJ-A ____ 30, weight (g) = (protective height) x 1.5 + α; The values for α are as follows:; Protected height 245 to 596 mm: = 1,100 protected height 1,660 to 2,180 mm: = 2,400; Protected height 600 to 1,130 mm: = 1,500 protected height 2,195 to 2,500 mm: = 2,600; Protected height 1,136 to 1,658 mm: = 2,000 |
| Withstand Voltage | 1,000 VAC 50/60 Hz, 1 min |