SX-D4220-E1FA4 – 220 kW three-phase variable frequency drive for induction motors

220 kW three-phase variable frequency drive for induction motors

Variable Frequency Drives (VFD)

  • 400 V three phase
  • IP54
  • Vector control
  • 200 kW
Manufacturer part number
SX-D4220-E1FA4
Manufacturer
Omron
Drive supply voltage
400 V three phase
Degree of protection (IP)
IP54

The Omron SX-D4220-E1FA4 variable frequency drive powers induction or permanent magnet motors up to 220 kW from a 400 V three-phase supply. It provides vector control and connects to several industrial fieldbuses.

Product overview

Omron SX-D4220-E1FA4. this variable frequency drive (VFD) from the SX series controls the speed and torque of electric motors supplied at 400 V three-phase.

Main characteristics. Motor output of 200 kW at constant torque and 220 kW at variable torque. The control method is vector control, and the drive accepts induction or asynchronous motors as well as permanent magnet motors. The degree of protection is IP54. Product dimensions are 600 mm wide, 600 mm deep and 2250 mm high, for a weight of 380 kg.

Interfaces and connectivity. The drive offers a wide range of communication options: Modbus slave, Modbus/TCP, EtherNet/IP, PROFINET slave, PROFIBUS DP slave, DeviceNet slave, EtherCAT slave, serial RS-232C and RS-485 links, and Bluetooth. These options allow integration into existing automation architectures.

Power supply and braking. The rated supply is 400 V three-phase. Regenerative solutions are available as an inverter option.

Typical uses. The drive suits the control of high-power motors in installations driven by a PLC, thanks to its industrial communication protocols.

Integration. The product is documented by the manufacturer through an instruction manual and a datasheet for the 400 V SX-series drives. It is available on quotation from Atlas Electronics.

See all specifications

Highlights

  • Compatible motor type: Induction or asynchronous motor, Permanent magnet motor
  • Degree of protection (IP): IP54
  • Drive control method: Vector control
  • Drive supply voltage: 400 V three phase
  • Max. motor output at constant torque: 200 kW
  • Max. motor output at variable torque: 220 kW

Good to know before integrating

  • Power: plan for a supply compatible with 400 V three phase.