Limited record: this part has neither specifications nor a datasheet in the catalog yet. It is shown for reference and is not indexed.

USR-N520 – 2-port RS-232/485 to Ethernet MQTT Modbus gateway

2-port RS-232/485 to Ethernet MQTT Modbus gateway

Protocol Gateways, Serial Device Servers & CAN Adapters

  • Ethernet
  • RS-485
  • Modbus
Manufacturer part number
2-PORT-SERIAL-DEVICE-SERVER-USR-N520
Manufacturer
PUSR

Secure 2-port RS-232/485 to Ethernet device server that connects serial equipment to TCP/IP networks and MQTT, with built-in Modbus RTU/TCP gateway.

Product overview

USR-N520. The PUSR USR-N520 is a 2-port serial device server and Modbus MQTT gateway that connects RS-232 or RS-485 equipment to TCP/IP networks for bidirectional communication.

Main characteristics. It provides two RS-232/485/422 serial ports, one RJ45 Ethernet port at 10/100 Mbps with auto MDI/MDIX, serial baud rates from 600 to 230.4 kbps, 7 or 8 data bits and none, even or odd parity. Flow control is available as none, RTS/CTS (RS-232 only) or XON/XOFF. A 2.2 kΩ pull-up and pull-down resistor is fitted on the RS-485 line.

Connectivity and protocols. The device supports TCP server, TCP client, UDP and HTTP client modes, with IP, TCP, UDP, ARP, ICMP, IPv4, DHCP and DNS network protocols, using static IP or DHCP addressing. MQTT and WebSocket communication is supported, with SSL/TLS encryption in TCP client, HTTP client and MQTT modes. The Modbus gateway function converts between Modbus RTU and Modbus TCP and supports multi-host polling. The Ethernet packet cache is 48 Kbyte and the serial packet cache is dynamic.

Power and environment. It runs from a DC input of 5.0 to 36.0 V, drawing 67 mA at 12 V. The operating temperature is -40 to 85 ℃ and the storage temperature is -40 to 105 ℃, with 5% to 95% RH humidity, non-condensing. The housing measures 150 × 98.8 × 30 mm (L × W × H, including terminals and mounting ears) and is panel mounted. Protection includes EFT immunity to IEC 61000-4-4 level 3 (±2 kV), ESD immunity to IEC 61000-4-2 level 4 (air ±15 kV, contact ±8 kV) and surge immunity to IEC 61000-4-5 level 3 (±2 kV). The product is certified CE, FCC and RoHS.

Typical uses. The device links PLCs or Modbus RTU equipment to an Ethernet network or an MQTT platform and supports remote monitoring. It can connect EV charging piles to a charging service platform, as shown in the manufacturer's application case.

Integration. Configuration is done with a setup utility, a web page or AT commands, and remote management is available through the PUSR Cloud platform.