USR-CAN518 – CANopen Slave to Modbus TCP and RTU Master Gateway

CANopen Slave to Modbus TCP and RTU Master Gateway

Serial-to-Ethernet Device Servers (RS-232/422/485)

  • -40~85℃
  • -40℃~+85℃
  • -40~105℃
  • DIN rail mounting
Manufacturer part number
CANOPEN-TO-MODBUS-CONVERTER
Manufacturer
PUSR
Operating Temperature
-40~85℃
Wide Operating Temperature
-40℃~+85℃

PUSR USR-CAN518 industrial gateway converting a CANopen slave protocol to Modbus TCP or Modbus RTU master, to connect Modbus devices to a CANopen controller.

Product overview

Overview. The PUSR USR-CAN518 is a CANopen slave to Modbus master gateway, designed to connect industrial Modbus devices to a CANopen master such as a programmable logic controller or a SCADA system.

Main characteristics. The product provides one CAN interface, one RS232/RS485 interface and one RJ45 Ethernet port at 100/1000 Mbps with auto MDI/MDIX. It includes a Type-C debugging port and a serial link configurable from 600 to 230.4K bps, with 7 or 8 data bits, none, odd or even parity, and 1 or 2 stop bits. A long press restores the factory settings.

Interfaces and connectivity. Protocol conversion runs from CANopen slave to Modbus TCP master or from CANopen slave to Modbus RTU master. The default IP address is static, 192.168.0.7. Two built-in 120 Ω CAN bus termination resistors are included.

Power and environment. The power input accepts 9 to 36 V DC with reverse polarity protection. Typical consumption is 46.26 mA at 12 V in working mode. The aluminum housing mounts on a DIN rail, with an operating temperature range of -40 to 85 °C and 5 to 95 % RH humidity, non-condensing. Protection includes 3000 VDC isolation for power, serial and Ethernet ports, EMC protection level 3, a dual hardware and software watchdog, and ESD immunity of 8 kV air discharge and 6 kV contact discharge.

Typical uses. The gateway lets you connect Modbus RTU or Modbus TCP sensors, instruments and field devices to an existing CANopen network without changing the master. Parameters are set with a user-friendly configuration utility.

See all specifications

Highlights

  • Baud rate: 600-230.4K(bps)
  • Connector: 2-PIN 5.08 terminal blocks
  • Data Bit: 7,8
  • Default IP: Static: 192.168.0.7
  • Dimension: 110*27*85.6 mm(Including terminal blocks)
  • Dual watchdog: hardware & software watchdog, ensure stable operating

Typical applications

Derived from the part category, not a compatibility statement.

Good to know before integrating

  • Thermal: rated operating range -40~85℃ — check it against the installation environment.
  • Thermal: rated operating range -40℃~+85℃ — check it against the installation environment.

See also

Technical questions

Ask a question

No published question about this part yet. Questions are reviewed before publication.

Request a quote