100057
I2C UV and Ambient Light Sensor for WisBlock

- Operating temperature ranges
- -40 to +85 ºC
- Lite-On
- LTR-390UV-01
- Model
- RAK12019
- Operating voltage ranges
- 1.7V to 3.6V
I2C UV and Ambient Light Sensor for WisBlock
RAK12019 UV and ambient light sensor module from RAKwireless, based on the Lite-On LTR-390UV-01, for UV exposure control and ambient light measurement.
Overview. The RAKwireless RAK12019 is a UV and ambient light sensor from the WisBlock sensor series, based on the Lite-On LTR-390UV-01. It measures either ambient light intensity (ALS) or the ultraviolet index (UVS).
Main characteristics. The sensor provides an effective resolution of 13 to 20 bits and a wide dynamic range of 1:18,000,000 with linear response. Its spectral response is close to that of the human eye, and it automatically rejects 50 Hz and 60 Hz lighting flicker. A programmable interrupt function allows upper and lower thresholds to be set for ALS and UVS.
Interfaces and connectivity. Communication is over an I2C bus, in Standard mode at 100 kHz or Fast mode at 400 kHz, with 1.8 V logic compatibility. The 24-pin connector carries the I2C_SDA, I2C_SCL and INT (IO1) signals.
Power and environment. The operating voltage ranges from 1.7 V to 3.6 V, with a nominal value of 3.3 V on the 3V3_S supply. The operating temperature range is -40 to +85 °C. Nominal active-mode current for ALS is 110 µA and nominal shutdown current is 1 µA at 2.8 V. The module includes a built-in temperature compensation circuit and a sleep mode with very low power consumption.
Typical uses. The module suits greenhouse control to protect plants from UV exposure, UV level warning systems, and building lighting and window shadowing applications.
Integration. The RAK12019 fits a WisBlock module slot and comes with sample code for WisBlock cores.
No published question about this part yet. Questions are reviewed before publication.
Every characteristic recorded for 100057, with where it comes from. Use the filters to find one quickly.
| Characteristic | Value |
|---|---|
| 3V3_S | Description: LTR-390UV-01 Operating Voltage; Condition: Input voltage must within this range; Min.: 2.5; Nom.: 3.3; Max.: 3.6; Unit: V |
| ALS | Description: ALS Active Mode Current; Condition: VMax. duty cycle, Vdd=2.8V, Gain 3x; Nom.: 110; Unit: uA |
| Isd | Description: Shut down current; Condition: VDD is 2.8 V; Nom.: 1; Unit: uA |
| Lite-On | LTR-390UV-01 |
| Model | RAK12019 |
| Operating temperature ranges | -40 to +85 ºC |
| Operating voltage ranges | 1.7V to 3.6V |
| Sample Code | RAK12019 (opens new window) |
| UVS | Description: UVS Active Mode Current; Condition: Max. duty cycle, Vdd=2.8V; Nom.: 100; Unit: uA |
| WakeupTime | Description: Wakeup Time from Standby; Condition: From Standby to Active mode where measurement can start; Nom.: 5; Max.: 10; Unit: ms |
| WB_IO3 | SLOT D: WB_IO5; SLOT E: WB_IO4; SLOT F: WB_IO6 |
No specification matches.
Last verification : 2026-10-31
Official documents and the technical data recorded for 100057. For a missing document or a specific revision, our experts send it to you.
RAK12019 UV and ambient light sensor module from RAKwireless, based on the Lite-On LTR-390UV-01, for UV exposure control and ambient light measurement.
| Parameter | Value |
|---|---|
| 3V3_S | Description: LTR-390UV-01 Operating Voltage; Condition: Input voltage must within this range; Min.: 2.5; Nom.: 3.3; Max.: 3.6; Unit: V |
| ALS | Description: ALS Active Mode Current; Condition: VMax. duty cycle, Vdd=2.8V, Gain 3x; Min.: -; Nom.: 110; Max.: -; Unit: uA |
| Isd | Description: Shut down current; Condition: VDD is 2.8 V; Min.: -; Nom.: 1; Max.: -; Unit: uA |
| Lite-On | LTR-390UV-01 |
| Model | RAK12019 |
| Operating temperature ranges | -40 to +85 ºC |
| Operating voltage ranges | 1.7V to 3.6V |
| Sample Code | RAK12019 (opens new window) |
| UVS | Description: UVS Active Mode Current; Condition: Max. duty cycle, Vdd=2.8V; Min.: -; Nom.: 100; Max.: -; Unit: uA |
| WakeupTime | Description: Wakeup Time from Standby; Condition: From Standby to Active mode where measurement can start; Min.: -; Nom.: 5; Max.: 10; Unit: ms |
| WB_IO3 | SLOT D: WB_IO5; SLOT E: WB_IO4; SLOT F: WB_IO6 |
Points to check before using 100057 in a design. They are derived from the recorded characteristics, not from the manufacturer's application circuits.
| Operating voltage ranges | 1.7V to 3.6V |
Check the exact pin assignment and the application circuit in the datasheet, or ask our experts.
Answers to the questions that the recorded characteristics of 100057 can answer. A question is not asked when nothing is recorded to answer it.
Yes — recorded under "WakeupTime": Description: Wakeup Time from Standby; Condition: From Standby to Active mode where measurement can start; Min.: -; Nom.: 5; Max.: 10; Unit: ms.
-40 to +85 ºC (source: Operating temperature ranges).
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
I2C UV and Ambient Light Sensor for WisBlock

UV Sensor

Describe your application and constraints in a request.
What is recorded about the regulatory status and the life of this part.
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
| Current status | Status not stated |
| Key dates | Not recorded |
| Manufacturer part number | 100057 |
| Family | UV Light Sensor Lite-On LTR-390UV-01 |
| Manufacturer | RAKwireless |
UV Sensors