Based on the LoRa Concentrator EngineSemtech® SX1302
Product overview
Overview. The RAK Hotspot V2 from RAKwireless is a ready-to-use LoRaWAN gateway designed for the Helium LongFi network and participation in Proof-of-Coverage. This AS923 outdoor bundle includes a 5 dBi fiber glass antenna and a UK standard power adapter.
Main characteristics. It is based on a Semtech SX1302 LoRa concentrator. In the AS923 band, output power is -6 dBm at PWID control 10 and 8 dBm at PWID control 0. Sensitivity reaches -139 dBm at spreading factor 12 with a bandwidth of 125, -136 dBm with 250 and -134 dBm with 500. The antenna peak gain is 2.8 dBi, its VSWR is at most 1.5 and its feed impedance is 50 Ohms.
Interfaces and connectivity. A Gigabit Ethernet port provides wired network connectivity. A LoRa antenna connector takes the external antenna for LoRaWAN communication. A TF card slot holds the system image and device data, and a pairing button is used for device pairing operations. LEDs indicate the operating status and system activity during startup.
Power and environment. Power is supplied through a USB-C connector. Consumption is 550 mA typical in standby and 950 mA maximum in LoRa Tx mode. The operating temperature range is -10 °C to +55 °C and the storage range is -40 °C to +85 °C. Working conditions are -35 to +75 °C at 5 to 95 % relative humidity.
Typical uses. This gateway suits an installation with an outdoor antenna to provide LoRaWAN coverage on a site, in the AS923 band and with a UK standard power plug. Available on quotation from Atlas Electronics.
Architectures in which A19012 can play a role, derived from its category. This is not a compatibility statement: check the specifications against your requirements.
Energy bills give one total for the whole site. Submetering places meters and current sensors on each circuit or usage and collects their readings through a gateway, so consumption can be followed per building, floor or machine
To check
Number of circuits and phases to meter, and the current range of each
Wired Modbus bus or wireless LoRaWAN, depending on cabling access in the switchboards
Accuracy class required for internal allocation or for billing
Offices and classrooms get stuffy without anyone measuring why. Indoor air quality monitoring places CO2, VOC and particle sensors in the rooms and reports their values through a gateway, so ventilation can be adjusted to real occupancy
To check
Parameters to measure (CO2 alone or CO2, VOC and particles)
Battery-powered sensors or mains-powered sensors with display
Integration with the ventilation control or building management system
A leak under a sink or in a technical room is often found days later. Leak detection places wireless sensors where water can appear and sends an alert through a gateway as soon as one of them gets wet
To check
Locations at risk: kitchens, bathrooms, plant rooms, server rooms
Alert path (SMS, e-mail, application) and who receives it
Battery life and the way a low battery is reported
A fridge that drifts at night can ruin a whole stock. Temperature loggers in cold rooms and trucks report through a gateway or a tracker and raise an alert when a threshold is crossed
To check
Temperature range and accuracy required by the product
Record keeping required by the applicable regulations
A LoRaWAN project needs sensors, gateways, a network server and an application that work together. Sensor nodes report to indoor or outdoor gateways, which forward the data to the network server and the customer’s platform
To check
Regional frequency plan (EU868, US915 and others)
Network server: public, private or embedded in the gateway
A building’s energy, comfort and occupancy data sit in separate systems. Sensors, meters and gateways feed one model of the building, room by room, to compare scenarios and steer the installations
Milesight sensors, LoRaWAN gateways and cellular routers can be brought together on the Milesight Development Platform, which manages the devices and passes their data to other applications through an API and webhooks
To check
Development Platform for device management, API and webhooks, or another network server and application
Devices provisioned through Milesight RPS must have that provisioning removed before being added to the Development Platform
Data flows to the customer’s own application through webhooks
RAKwireless WisGate gateways run WisGateOS 2 and are managed from WisDM, RAKwireless’ cloud device management platform with a built-in network server, alongside RAK sensor nodes, radio modules and concentrators
To check
WisDM built-in network server, or a third-party one (ChirpStack, TTN/TTS, AWS IoT Core, Actility)
Remote configuration and updates of the gateways from WisDM
Regional frequency plan of the gateways and nodes
Associated system blocks
GatewaysSensors and modulesDevelopment boardsMounting
Need a complete solution?
Send a request for A19012 and the other parts of your project.
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
What is recorded about the regulatory status and the life of this part.
Regulatory compliance
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
No advertising or analytics cookies. A single, strictly necessary cookie is set only if you sign in to your account. Your quote basket and comparison stay in your browser. Details