E1049 – Single-phase two-wire smart energy meter

Single-phase two-wire smart energy meter

Single-Phase Energy Meters

  • -25~70℃
  • 80%Un 115%Un
  • 100A
  • 0.5A
Manufacturer part number
195064278
Manufacturer
Reallin
Operating Temperature
-25~70℃
Voltage Range
80%Un 115%Un

Single-phase two-wire smart energy meter for 230 V, 50 Hz AC systems, measuring active and reactive energy for billing and grid management.

Product overview

Overview. The Reallin E1049 is a single-phase two-wire smart energy meter designed for AC power systems rated 230 V and 50 Hz. It measures active and reactive energy, with accuracy Class 1.0 for active energy and Class 2.0 for reactive energy.

Main characteristics. Reference current 10 A, minimum current 0.5 A, maximum current 100 A and starting current 0.4% Ib. Meter constant of 1000 imp/kWh and 1000 imp/kvarh, indicated by an LED pulsating indicator. The 8-digit LCD display offers a configurable decimal place and backlight.

Interfaces and connectivity. One optical port and a module compartment (cellular, RF, PLC or LoRa) enable remote communication. The DLMS/COSEM protocol handles data exchange, with data transportation encryption (Suite 0).

Backup power and clock. A replaceable battery and an internal super capacitor provide backup power. A real-time clock compliant with IEC 62054-21 is built in.

Power and environment. Voltage range 80% Un to 115% Un. Typical consumption of 2 W / 10 VA on the voltage circuit and 4 VA on the current circuit. Operating temperature -25 to 70 °C, storage temperature -40 to 85 °C, protection degree IP 54. Weight about 0.9 kg, dimensions 246.1 × 129.5 × 68.0 mm.

Load control. Built-in latching relay, maximum 250 V and 120 A, utilization category UC3 according to IEC 62052-31.

Standards. IEC 62052-11, IEC 62053-21/23, IEC 62056-21, IEC 62056-61 and IEC 62059-32-1.

Available on quotation from Atlas Electronics.

See all specifications

Highlights

  • Backup power supply: Replaceable battery and Internal super capacitor
  • Communication Protocol: DLMS/COSEM, Support data transportation encryption (Suite 0)
  • LCD display: 8 digits with configurable decimal place, backlight supported
  • Maximum Current: 100A
  • Minimum current: 0.5A
  • Operating Temperature: -25~70℃

Typical applications

Derived from the part category, not a compatibility statement.

Good to know before integrating

  • Thermal: rated operating range -25~70℃ — check it against the installation environment.

See also

Technical questions

Ask a question

No published question about this part yet. Questions are reviewed before publication.