Reallin E1053 single-phase two-wire active energy meter for measuring electricity consumption on 230V, 50Hz networks, with pulse output and SML communication.
Operation Temperature Range-40~70℃
Storage Temperature Range-40~85℃
Voltage Range80%Un~115%Un
Current Circuit Power Consumption<4VA
Minimum current0.25A
Reference Current60A
Product overview
Overview. The Reallin E1053 single-phase two-wire energy meter is an active energy meter designed to measure consumption on 230V, 50Hz single-phase networks. It complies with EN 50470-1, EN 50470-3 and EN 62052-31:2016.
Main characteristics. Rated voltage of 230V with a voltage range of 80% to 115% of Un, reference current Ib of 60A, minimum current of 0.25A and starting current of 0.4% Ib. Accuracy is class B for active energy. The meter features a double-line LCD display with 6 digits for energy, and an LED delivering 10000 imp/kWh.
Interfaces and connectivity. The meter provides an optical port and a TTL port for plug-in LMN, LoRa, RS485 or Bluetooth modules (optional), as well as an optional internal Bluetooth. It communicates using the SML protocol and includes an input for external tariff terminals.
Power and environment. Power consumption is below 2 W / 10 VA on the voltage circuit and below 4 VA on the current circuit. It operates between -40 and 70 °C and can be stored between -40 and 85 °C. Its protection degree is IP 51. Dimensions are 190.5 × 129.5 × 67.9 mm for about 0.6 kg.
Typical uses and integration. This meter suits single-phase energy consumption metering and can be extended into a smart meter using its plug-in modules. It is available on quotation from Atlas Electronics.
Reallin E1053 single-phase two-wire active energy meter for measuring electricity consumption on 230V, 50Hz networks, with pulse output and SML communication.
Operation Temperature Range-40~70℃
Storage Temperature Range-40~85℃
Voltage Range80%Un~115%Un
Current Circuit Power Consumption<4VA
Minimum current0.25A
2. Datasheet extract (recorded values)
Parameter
Value
Accuracy
Class B for active
Communication Protocol
SML
Current Circuit Power Consumption
<4VA
Dimensions (LxWxD)
190.5 × 129.5 × 67.9mm
LCD display
Double line display, 6 digits for energy display
LED
10000imp/kWh
Minimum current
0.25A
Operation Temperature Range
-40~70℃
Protection degree
IP 51
Pulsating Indicator
Pulsating (meter constant)
Rated Frequency
50Hz
Rated Voltage
230V
Reference Current
60A
Standards
EN 50470-1, EN 50470-3, EN 62052-31:2016
Starting Current
0.4%Ib
Storage Temperature Range
-40~85℃
Type
Single Phase Two Wire Energy Meter
Voltage Circuit Power Consumption
<2W/10VA
Voltage Range
80%Un~115%Un
Weight
About 0.6kg
Applications and use cases
Architectures in which 195163897 can play a role, derived from its category. This is not a compatibility statement: check the specifications against your requirements.
Energy bills give one total for the whole site. Submetering places meters and current sensors on each circuit or usage and collects their readings through a gateway, so consumption can be followed per building, floor or machine
To check
Number of circuits and phases to meter, and the current range of each
Wired Modbus bus or wireless LoRaWAN, depending on cabling access in the switchboards
Accuracy class required for internal allocation or for billing
Solar panels produce most when nobody is home, and the surplus goes to the grid. A battery with its inverter stores this energy and returns it in the evening, with a meter measuring what the home draws
To check
Panel power and the inverter compatibility of the battery
Usable capacity compared with the evening and night consumption
Local grid connection rules for balcony and home systems
Associated system blocks
InvertersBatteryMetering
Need a complete solution?
Send a request for 195163897 and the other parts of your project.
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
Current productReallin
195163897
Single-phase two-wire active energy meter, class B
What is recorded about the regulatory status and the life of this part.
Regulatory compliance
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.