Three phase four wire DIN rail energy meter for measuring active and reactive energy through current transformers, with RS485 communication and S0 pulse output.
Operating Temperature-25 55℃
Voltage Range80%Un 120%Un
Current Circuit Power Consumption<1VA
Minimum current0.01A
Starting Current0.1%In
Voltage Circuit Power Consumption<2W/10VA
Product overview
Overview. The Reallin D3034 is a three phase four wire DIN rail energy meter designed to measure active and reactive energy on a connection with current transformers. It measures active energy to class C and reactive energy to class 2.
Main characteristics. Rated voltage 3x230/400V with a voltage range of 80% to 120% of Un, rated frequency 50 Hz, minimum current 0.01 A and starting current 0.1% of In. The 8-digit LCD display, with configurable decimal place and backlight, allows local reading.
Interfaces and connectivity. RS485 with screw-type terminals, up to 38400 bps, for integration into a supervision system. An LED and an S0 output deliver pulses with a meter constant of 10000 imp/kWh and 10000 imp/kvarh, the S0 interface being configurable. A relay output is also provided.
Power and environment. Voltage circuit consumption below 2 W / 10 VA and current circuit consumption below 1 VA. Operating temperature from -25 to 55 ℃, storage temperature from -40 to 70 ℃, protection degree IP 51 in protective enclosure. Weight about 0.3 kg, dimensions 86.0 x 87.5 x 62.0 mm.
Standards and uses. Compliant with EN 50470-1, EN 50470-3 and IEC 62053-23. The meter suits energy metering on electrical panels and data transfer to a PLC or supervisory system via the Modbus protocol.
Three phase four wire DIN rail energy meter for measuring active and reactive energy through current transformers, with RS485 communication and S0 pulse output.
Operating Temperature-25 55℃
Voltage Range80%Un 120%Un
Current Circuit Power Consumption<1VA
Minimum current0.01A
Starting Current0.1%In
2. Datasheet extract (recorded values)
Parameter
Value
Accuracy
Class C for active, Class 2 for reactive
Communication interface
RS485 with screw type, maximum upto 38400bps
Current Circuit Power Consumption
<1VA
Dimension(LxWxD)
86.0 x 87.5 x 62.0mm
LCD display
8 digits with configurable decimal place, backlight supported
Minimum current
0.01A
Operating Temperature
-25 55℃
Protection degree
IP 51 in protective enclosure
Pulsating Indicator
LED and S0 interface
Pulsating(meter constant)
10000imp/kWh, 10000imp/kvarh, configurable for S0 interface
Rated Frequency
50Hz
Rated Voltage
3x230/400V
Standards
EN 50470-1, EN 50470-3, IEC 62053-23
Starting Current
0.1%In
Storage Temperature
-40 70℃
Type
Three Phase Four Wire DIN Rail CT Meter
Voltage Circuit Power Consumption
<2W/10VA
Voltage Range
80%Un 120%Un
Weight
About 0.3kg
Integration
Points to check before using 195454487 in a design. They are derived from the recorded characteristics, not from the manufacturer's application circuits.
1Thermalrated operating range -25 55℃ — check it against the installation environment.
Power and communication
Current Circuit Power Consumption
<1VA
Minimum current
0.01A
Rated Voltage
3x230/400V
Starting Current
0.1%In
Voltage Circuit Power Consumption
<2W/10VA
Voltage Range
80%Un 120%Un
Check the exact pin assignment and the application circuit in the datasheet, or ask our experts.
Implementation checklist
Thermal : rated operating range -25 55℃ — check it against the installation environment.
Applications and use cases
Architectures in which 195454487 can play a role, derived from its category. This is not a compatibility statement: check the specifications against your requirements.
Energy bills give one total for the whole site. Submetering places meters and current sensors on each circuit or usage and collects their readings through a gateway, so consumption can be followed per building, floor or machine
To check
Number of circuits and phases to meter, and the current range of each
Wired Modbus bus or wireless LoRaWAN, depending on cabling access in the switchboards
Accuracy class required for internal allocation or for billing
A building’s energy, comfort and occupancy data sit in separate systems. Sensors, meters and gateways feed one model of the building, room by room, to compare scenarios and steer the installations
To check
Data model and building plans available
Software platform hosting the twin
Sensor density needed for a useful model
Associated system blocks
SensorsMetersGateways
Need a complete solution?
Send a request for 195454487 and the other parts of your project.
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
What is recorded about the regulatory status and the life of this part.
Regulatory compliance
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.