The Reallin DDS1226 is a single-phase two-wire DIN rail active energy meter for measuring loads on 230 V AC networks and for sub-metering applications.
Product overview
Single-phase DDS1226 meter from Reallin. The Reallin DDS1226 is a single-phase two-wire active energy meter in DIN rail format, designed to measure energy consumed on a 230 V, 50 Hz single-phase AC network.
Main characteristics. Accuracy class B/1.0 for active energy and 2.0 for reactive energy, reference current Ib of 5 A, maximum current Imax of 45 A, minimum current of 0.2 A and starting current of 0.4% Ib. 6-digit LCD display, LED pulse indicator and meter constant of 1000 imp/kWh. 1 TE width, dimensions 62 x 60 x 17.5 mm, weight about 0.08 kg. Voltage range 80% to 120% Un.
Interfaces and connectivity. RS485 port with screw terminals, up to 115200 bps, supporting the Modbus protocol for data exchange with PLCs or supervision systems.
Power and environment. Current circuit apparent power below 4 VA and voltage circuit below 2 W / 8 VA. Insulation class II, protection degree IP51 in protective enclosure, operating temperature from -30 °C to 70 °C.
Typical uses. Sub-metering and billing by tariff, including AC electric vehicle charging stations, distribution boards and control cabinets where compact installation is required.
Standards and integration. Compliant with EN 50470-1, EN 50470-3 and IEC 62053-23:2020, with MID certification. Only the live and neutral wires need to be connected, which simplifies wiring and maintenance.
The Reallin DDS1226 is a single-phase two-wire DIN rail active energy meter for measuring loads on 230 V AC networks and for sub-metering applications.
2. Datasheet extract (recorded values)
Parameter
Value
Accuracy
single phase Two wire DIN Rai IMeter--DDS1226: class B/1.0 for active; class 2.0 for reactive
Communication interface
single phase Two wire DIN Rai IMeter--DDS1226: RS485with screw type,maximum upto 115200b ps
Current circuit apparent power at Ib
single phase Two wire DIN Rai IMeter--DDS1226: <4VA
Dimension(LXW XD)
single phase Two wire DIN Rai IMeter--DDS1226: 62x gox.17.5mm
Insulation Class
single phase Two wire DIN Rai IMeter--DDS1226: II
LCD display
single phase Two wire DIN Rai IMeter--DDS1226: 6digits
Maximum current Imax
single phase Two wire DIN Rai IMeter--DDS1226: 45A
Minimum Current (Imin)
single phase Two wire DIN Rai IMeter--DDS1226: 0.2A
Protection degree
single phase Two wire DIN Rai IMeter--DDS1226: IP51 in protective enclosure
Pulsating Indicator
single phase Two wire DIN Rai IMeter--DDS1226: LED
Pulsating(meter constant)
single phase Two wire DIN Rai IMeter--DDS1226: 1000 imp/kwh
Rated Frequency Fn
single phase Two wire DIN Rai IMeter--DDS1226: 50HZ
Rated votage un
single phase Two wire DIN Rai IMeter--DDS1226: 230V
Reference current Ib
single phase Two wire DIN Rai IMeter--DDS1226: 5A
Standards
single phase Two wire DIN Rai IMeter--DDS1226: EN50470-1,EN50470-3,IEC62053-23:2020
Starting Current (Ist)
single phase Two wire DIN Rai IMeter--DDS1226: 0.4%Ib
Temperature range
single phase Two wire DIN Rai IMeter--DDS1226: operation:-30-70℃
voltage circuit active lap parent power atun
single phase Two wire DIN Rai IMeter--DDS1226: <2W/8VA
Voltage Range
single phase Two wire DIN Rai IMeter--DDS1226: 80%un~120%un
Weight Of Meter
single phase Two wire DIN Rai IMeter--DDS1226: About0.08kg
Applications and use cases
Architectures in which 271885264 can play a role, derived from its category. This is not a compatibility statement: check the specifications against your requirements.
Energy bills give one total for the whole site. Submetering places meters and current sensors on each circuit or usage and collects their readings through a gateway, so consumption can be followed per building, floor or machine
To check
Number of circuits and phases to meter, and the current range of each
Wired Modbus bus or wireless LoRaWAN, depending on cabling access in the switchboards
Accuracy class required for internal allocation or for billing
A building’s energy, comfort and occupancy data sit in separate systems. Sensors, meters and gateways feed one model of the building, room by room, to compare scenarios and steer the installations
To check
Data model and building plans available
Software platform hosting the twin
Sensor density needed for a useful model
Associated system blocks
SensorsMetersGateways
Need a complete solution?
Send a request for 271885264 and the other parts of your project.
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
Current productReallin
271885264
Single-phase two-wire DIN rail energy meter, class B
Temperature range
single phase Two wire DIN Rai IMeter--DDS1226: operation:-30-70℃
Voltage Range
single phase Two wire DIN Rai IMeter--DDS1226: 80%un~120%un
Communication interface
single phase Two wire DIN Rai IMeter--DDS1226: RS485with screw type,maximum upto 115200b ps
Current circuit apparent power at Ib
single phase Two wire DIN Rai IMeter--DDS1226: <4VA
What is recorded about the regulatory status and the life of this part.
Regulatory compliance
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
With your consent, we use Google cookies to measure the site’s audience and our advertising. Your quote basket and comparison stay in your browser either way. Details