DDS1226 single-phase two-wire energy meter from Reallin, designed to measure active energy on 230 V, 50 Hz single-phase circuits, with RS485 communication output.
Temperature rangeDDS1226: operation:-30-70℃
Voltage RangeDDS1226: 80%un~120%un
Current circuit apparent power at IbDDS1226: <4VA
Maximum current ImaxDDS1226: 45A
Minimum Current (Imin)DDS1226: 0.2A
Reference current IbDDS1226: 5A
Product overview
Overview. The DDS1226 single-phase two-wire meter from Reallin is an energy meter designed for 230 V, 50 Hz single-phase circuits in residential and small-power applications.
Main characteristics. Class B/1.0 for active energy and class 2.0 for reactive energy, reference current Ib of 5 A and maximum current Imax of 45 A, starting current Ist of 0.4% Ib and minimum current Imin of 0.2 A. Voltage range of 80% un to 120% un, meter constant of 1000 imp/kWh, 6-digit LCD display and LED pulse indicator.
Interfaces and connectivity. RS485 communication interface with screw terminals, up to 115200 bps, allowing remote reading of consumption data.
Power and environment. Voltage circuit consumption of 2 W / 8 VA and current circuit apparent power below 4 VA at Ib. Operating temperature from -30 to 70 °C, protection degree IP51 in a protective enclosure, insulation class II. Dimensions 62 x 70 x 17.5 mm and weight of about 0.08 kg.
Standards. Compliant with EN 50470-1, EN 50470-3 and IEC 62053-23:2020.
Integration. Meter intended for connection to single-phase networks, whose RS485 output allows integration into a supervision or serial meter-reading system.
DDS1226 single-phase two-wire energy meter from Reallin, designed to measure active energy on 230 V, 50 Hz single-phase circuits, with RS485 communication output.
Temperature rangeDDS1226: operation:-30-70℃
Voltage RangeDDS1226: 80%un~120%un
Current circuit apparent power at IbDDS1226: <4VA
Maximum current ImaxDDS1226: 45A
Minimum Current (Imin)DDS1226: 0.2A
2. Datasheet extract (recorded values)
Parameter
Value
Accuracy
DDS1226: class B/1.0 for active; class 2.0 for reactive
Architectures in which 273475207 can play a role, derived from its category. This is not a compatibility statement: check the specifications against your requirements.
Energy bills give one total for the whole site. Submetering places meters and current sensors on each circuit or usage and collects their readings through a gateway, so consumption can be followed per building, floor or machine
To check
Number of circuits and phases to meter, and the current range of each
Wired Modbus bus or wireless LoRaWAN, depending on cabling access in the switchboards
Accuracy class required for internal allocation or for billing
Solar panels produce most when nobody is home, and the surplus goes to the grid. A battery with its inverter stores this energy and returns it in the evening, with a meter measuring what the home draws
To check
Panel power and the inverter compatibility of the battery
Usable capacity compared with the evening and night consumption
Local grid connection rules for balcony and home systems
Associated system blocks
InvertersBatteryMetering
Need a complete solution?
Send a request for 273475207 and the other parts of your project.
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
What is recorded about the regulatory status and the life of this part.
Regulatory compliance
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
With your consent, we use Google cookies to measure the site’s audience and our advertising. Your quote basket and comparison stay in your browser either way. Details