RS-KTCF-N01-*-T – Infrared Air Conditioner Controller with RS485 Modbus-RTU Interface

Infrared Air Conditioner Controller with RS485 Modbus-RTU Interface

General Industrial Sensors & Transmitters

  • 0.3W
  • Reserved
  • Remarks
  • DC 10~30V
Manufacturer part number
AIR-CONDITIONER-CONTROLLER-FOR-HVAC-SYSTEM
Manufacturer
Renke
Power consumption
0.3W

Wall-mounted air conditioner controller that learns infrared codes and connects over an RS485 Modbus-RTU bus to operate an air conditioner remotely, replacing the remote control.

Product overview

Renke air conditioner controller RS-KTCF-N01-*-T — This wall-mounted air conditioner controller from Renke operates an air conditioner by learning its infrared control codes, replacing the original remote control. It is designed for monitoring the operating status of air conditioners and for energy-saving management in HVAC systems.

Main characteristics. The sheet metal housing features pluggable terminal blocks for convenient wiring. The controller can learn 60 button functions. It retains its settings during a power outage and can automatically restart the air conditioner when power is restored. The Alarm function is reserved.

Interfaces and connectivity. RS485 interface using the standard Modbus-RTU protocol, with a configurable Modbus address and adjustable baud rates of 2400, 4800 and 9600. An infrared learning receiver (Learn) allows code learning, and outputs Y1 and Y2 drive external infrared LEDs, with an extension cable reaching up to 5 metres. Two current transformers, H1 and H2, can be connected.

Power and environment. Power supply of 10 to 30 V DC on the VCC and GND terminals, through only one of the two power supply ports, with a power consumption of 0.3 W. Operating range from -20 °C to +60 °C, at 0 to 95 % RH non-condensing.

Typical uses. In a supervision system connected to a PLC or a Modbus gateway, the controller lets one master unit remotely time the on and off operation of two air conditioners and collect the temperature at the installation location. It can also switch the air conditioner automatically according to preset minimum or maximum temperature thresholds.

Integration. The controller communicates with the master unit over an RS485 bus. Available on quotation from Atlas Electronics.

See all specifications

Highlights

  • Alarm: Reserved
  • Communication — Baud rate: 2400, 4800, 9600 (adjustable)
  • Communication interface: RS485 (standard ModBus-RTU protocol)
  • H1- — Current transformer negative terminal: First current transformer
  • H1+ — Current transformer positive terminal: First current transformer
  • H2- — Current transformer negative terminal: Second current transformer

Typical applications

Derived from the part category, not a compatibility statement.

See also

Technical questions

Ask a question

No published question about this part yet. Questions are reviewed before publication.

Request a quote