Renke electrochemical chlorine gas sensor with analog and RS485 outputs, for continuous monitoring of chlorine concentration in air.
Pressure range90~110kPa
Measure range0~20ppm, 0~50ppm or 0~100ppm
Measurement Range0~20ppm/0~50ppm/0~100ppm
Power consumption0.25W
Accuracy±10%
Response time≤60s
Product overview
Overview. The Renke RS-CL2-*-*-T chlorine gas sensor is an electrochemical chlorine gas sensor designed to continuously measure chlorine concentration in ambient air. It can send an alarm by text message and phone call when the limit is exceeded.
Main characteristics. The measurement range is 0~20ppm, 0~50ppm or 0~100ppm, with a resolution of 0.1ppm for the 0~20ppm and 0~50ppm ranges and 1ppm for the 0~100ppm range. Accuracy is ±10%, chlorine zero drift ±3%FS, repeatability ≤3% and stability ≤2% of signal value per month. Response time is ≤60s and preheating time ≥5mins. Service life is at least 24 months.
Interfaces and connectivity. Available outputs are 4-20mA, 0-5V, 0-10V and RS485.
Power and environment. Power supply is 10~30V DC, power consumption 0.25W. The sensor operates between -20 and 50℃ and between 15 and 90%RH without condensation. The operating pressure range is 90~110kPa.
Typical uses. The sensor is suited to chlorine monitoring in workshops, chemical plants, the electronics industry and enclosed spaces where real-time measurement is required.
Integration. The RS485 output allows connection to a supervision system, and the 4-20mA, 0-5V or 0-10V analog outputs to a standard measurement input.
Renke electrochemical chlorine gas sensor with analog and RS485 outputs, for continuous monitoring of chlorine concentration in air.
Pressure range90~110kPa
Measure range0~20ppm, 0~50ppm or 0~100ppm
Measurement Range0~20ppm/0~50ppm/0~100ppm
Power consumption0.25W
Accuracy±10%
2. Datasheet extract (recorded values)
Parameter
Value
Pressure range
90~110kPa
Response time
≤60s
Accuracy
±10%
Chlorine Zero Drift
±3%FS
Measure range
0~20ppm, 0~50ppm or 0~100ppm
Measurement Range
0~20ppm/0~50ppm/0~100ppm
Model
RS-CL2-*-*-T
Output signal
4-20mA/0-5V/0-10V/RS485
Power consumption
0.25W
Power supply
10~30V DC
Preheating Time
≥5mins
Repeatability
≤3%
Resolution
0~100ppm:1ppm; 0~20ppm/0~50ppm:0.1ppm
Service Life
≥24Months
Stability
≤2% signal value/month
Working humidity
15~90%RH No Condensation
Working temperature
-20~50℃
Applications and use cases
Architectures in which CHLORINE-GAS-SENSOR can play a role, derived from its category. This is not a compatibility statement: check the specifications against your requirements.
Offices and classrooms get stuffy without anyone measuring why. Indoor air quality monitoring places CO2, VOC and particle sensors in the rooms and reports their values through a gateway, so ventilation can be adjusted to real occupancy
To check
Parameters to measure (CO2 alone or CO2, VOC and particles)
Battery-powered sensors or mains-powered sensors with display
Integration with the ventilation control or building management system
Associated system blocks
Air sensorsGateway
Need a complete solution?
Send a request for CHLORINE-GAS-SENSOR and the other parts of your project.
Answers to the questions that the recorded characteristics of CHLORINE-GAS-SENSOR can answer. A question is not asked when nothing is recorded to answer it.
1Does it support RS-485?
Yes — recorded under "Output signal": 4-20mA/0-5V/0-10V/RS485.
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
Current productRenke
CHLORINE-GAS-SENSOR
Electrochemical chlorine gas sensor with multiple outputs
What is recorded about the regulatory status and the life of this part.
Regulatory compliance
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
With your consent, we use Google cookies to measure the site’s audience and our advertising. Your quote basket and comparison stay in your browser either way. Details