Product overview
Overview. The Renke RS-DOPL-N01-1/2-T is an ultrasonic Doppler flow meter that measures flow velocity from frequency changes and simultaneously measures water level and water temperature. It is intended for open channels, rivers and partially filled pipes.
Main characteristics. Flow velocity range of 0.03 to 10 m/s with an accuracy of ±1.0% ±1 cm/s (@0.03~5 m/s). Cumulative flow range of 0.1 to 999999 m³ and instantaneous flow range of 0 to 99.99 m³. Water level range of 0.03 to 5 m with an accuracy of 0.3% ±0.5 cm. Temperature range of -10 °C to 60 °C with an accuracy of ±1 °C. Default measurement interval of 3 s, adjustable, minimum no less than 2 s. The model measures in both directions and separately calculates positive cumulative flow, negative cumulative flow and net flow.
Interfaces and connectivity. RS485 signal output.
Power and environment. DC power supply from 10 to 30 V. Consumption of 72 mA/12 V in standby and 126 mA/12 V during measurement. Protection rating IP68. Operating temperature from -10 °C to 60 °C.
Typical uses. Monitoring of flow and levels in open channels and rivers, with the option of connecting the manufacturer's handheld data logger for measurements at different locations.
Integration. The RS485 output allows connection to a supervisory system or a PLC over a serial link.