RS-FPC-*-*-T – Explosion-proof fixed gas detector with RS485 and 4-20 mA outputs

Explosion-proof fixed gas detector with RS485 and 4-20 mA outputs

Environmental and Gas Sensors

Manufacturer part number
FIXED-GAS-DETECTOR
Manufacturer
Renke

Renke RS-FPC fixed gas detector, permanently installed to continuously monitor gas concentration in the ambient air and trigger an audible and visual alarm when a preset threshold is exceeded.

Product overview

Renke RS-FPC-*-*-T. fixed gas detector — The Renke RS-FPC-*-*-T fixed gas detector continuously monitors gas concentration in a warehouse or workplace. When the concentration exceeds the preset alarm value, it sends an audible and visual alarm signal. The model is available for several gases: O2, H2, H2S, CO, CO2, SO2, NO2, NH3, PH3, O3, Cl2, N2 and formaldehyde.

Main characteristics. The electrochemical sensor offers high sensitivity and strong anti-interference performance, with a proprietary compensation algorithm and multi-point standard gas calibration. Repeatability, stability and accuracy are documented by the manufacturer. A large LCD display facilitates on-site reading. Parameters can be adjusted remotely by infrared control, without disassembly.

Interfaces and connectivity. Available outputs are RS485, 0-5 V, 0-10 V and 4-20 mA. The RS485 link uses the standard Modbus RTU protocol, with configurable address and baud rate, and a maximum communication distance of 2000 metres. A relay output accepts 250 VAC 1 A or 30 VDC 1 A.

Power and environment. Power supply is 10 to 30 V DC. The wall-mounted enclosure has an IP66 rating. Operating temperature is -20 to 50 °C for most gases; operating humidity is 15 to 90 %RH non-condensing for NH3, H2, CO, H2S, NO2, SO2, O3, PH3, CH2O and Cl2, and 5 to 95 %RH non-condensing for O2 and N2. Explosion-proof markings are Ex db IIC T6 Gb and Ex tb IIIC T80°C Db.

Typical uses and integration. The detector suits harsh outdoor industrial environments. With its RS485 output in Modbus RTU, it can be connected to a PLC or a supervision system. Installation heights depend on the gas detected: for example, 0.3 to 0.6 m above the bottom of the monitored space for carbon dioxide, nitrogen dioxide, ozone and sulfur dioxide, and up to 2.0 m above the release source for hydrogen and methane.