- Temperature range
- -5~+80℃
- Temp. compensation range
- -5~+80℃ (default is 25℃)
- Power consumption
- 0.4W
- EC measure error
- ±1%FS
Integrated Conductivity Sensor with Modbus RTU Output
Renke integrated conductivity sensor measuring solution conductivity, TDS and salinity, with RS485 Modbus RTU output for reading by customer software or connection to a handheld water quality analyzer.
Renke RS-EC-N01-3-T. integrated conductivity sensor. This Renke conductivity sensor measures solution conductivity, temperature, TDS and salinity at the same time.
Main characteristics. Conductivity measurement with automatic temperature compensation (default coefficient 0.02, compensation range -5 to +80 °C, default reference 25 °C). EC range of 1 to 2000 µS/cm for K=1 and 10 to 20000 µS/cm for K=10, with an error of ±1%FS. Temperature range of -5 to +80 °C, error ±0.5 °C, resolution 0.1 °C. Integrated design with no extra accessories, default cable length of 5 m, other lengths can be customized.
Interfaces and connectivity. RS485 output with standard Modbus RTU protocol. Default baud rate is 4800, selectable from 1200 to 115200 baud. The Modbus communication address can be set. Data can be read through the customer's own software or connected to the manufacturer's handheld water quality analyzer.
Power and environment. DC 10 to 30 V power supply, power consumption 0.4 W. Waterproof housing with protection class IP68, pressure resistance 0.6 MPa, temperature resistance -20 to +80 °C.
Typical uses. Water quality monitoring in aquaculture, sewage treatment, environmental protection, pharmaceuticals and tap water purification, connected to a PLC or supervision system via Modbus RTU.
Integration. The sensor generally requires no daily maintenance. Calibration before each use is recommended, and every 3 months for long-term use, to be adjusted to the application conditions. Available on quotation from Atlas Electronics.
No published question about this part yet. Questions are reviewed before publication.
Every characteristic recorded for INTEGRATED-CONDUCTIVITY-SENSOR, with where it comes from. Use the filters to find one quickly.
| Characteristic | Value |
|---|---|
| Communication interface | Standard ModBus-RTU protocol; Communication baud rate: default 4800 (1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200 can be set) |
| EC measure error | ±1%FS |
| EC measure range — K=1 | 1~2000μS/cm |
| EC measure range — K=10 | 10~20000μS/cm |
| EC resolution — K=1 | 0.1μS/cm |
| EC resolution — k=10 | 1μS/cm |
| Model | RS-EC-N01-3-T |
| Power consumption | 0.4W |
| Power supply | DC 10~30V |
| Pressure Resistance | 0.6MPa |
| Protect class | IP68 |
| Salinity measure range — K=1 | 0~1000ppm |
| Salinity measure range — K=10 | 0~11476ppm |
| TDS measure range — K=1 | 0~1100ppm |
| TDS measure range — K=10 | 0~13400ppm |
| Temp compensation coefficient | default 0.02 |
| Temp. compensation range | -5~+80℃ (default is 25℃) |
| Temperature measure error | ±0.5℃ |
| Temperature range | -5~+80℃ |
| Temperature Resistance | -20~+80℃ |
| Temperature Resolution | 0.1℃ |
| Wire length | Default 5m (other lengths can be customized) |
No specification matches.
Last verification : 2026-11-02
Official documents and the technical data recorded for INTEGRATED-CONDUCTIVITY-SENSOR. For a missing document or a specific revision, our experts send it to you.
Renke integrated conductivity sensor measuring solution conductivity, TDS and salinity, with RS485 Modbus RTU output for reading by customer software or connection to a handheld water quality analyzer.
| Parameter | Value |
|---|---|
| Communication interface | Standard ModBus-RTU protocol; Communication baud rate: default 4800 (1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200 can be set) |
| EC measure error | ±1%FS |
| EC measure range — K=1 | 1~2000μS/cm |
| EC measure range — K=10 | 10~20000μS/cm |
| EC resolution — K=1 | 0.1μS/cm |
| EC resolution — k=10 | 1μS/cm |
| Model | RS-EC-N01-3-T |
| Power consumption | 0.4W |
| Power supply | DC 10~30V |
| Pressure Resistance | 0.6MPa |
| Protect class | IP68 |
| Salinity measure range — K=1 | 0~1000ppm |
| Salinity measure range — K=10 | 0~11476ppm |
| TDS measure range — K=1 | 0~1100ppm |
| TDS measure range — K=10 | 0~13400ppm |
| Temp compensation coefficient | default 0.02 |
| Temp. compensation range | -5~+80℃ (default is 25℃) |
| Temperature measure error | ±0.5℃ |
| Temperature range | -5~+80℃ |
| Temperature Resistance | -20~+80℃ |
| Temperature Resolution | 0.1℃ |
| Wire length | Default 5m (other lengths can be customized) |
Answers to the questions that the recorded characteristics of INTEGRATED-CONDUCTIVITY-SENSOR can answer. A question is not asked when nothing is recorded to answer it.
Yes — recorded under "Communication interface": Standard ModBus-RTU protocol; Communication baud rate: default 4800 (1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200 can be set).
Yes — recorded under "Communication interface": Standard ModBus-RTU protocol; Communication baud rate: default 4800 (1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200 can be set).
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
Integrated Conductivity Sensor with Modbus RTU Output

SUP-ADE3500 Inductive conductivity electrode

SUP-ADE3300 Conductivity Sensor for Pure Water and Water Treatment

TDS 7001G Conductivity sensor for data center

Describe your application and constraints in a request.
What is recorded about the regulatory status and the life of this part.
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
| Current status | Status not stated |
| Key dates | Not recorded |
| Manufacturer part number | INTEGRATED-CONDUCTIVITY-SENSOR |
| Manufacturer | Renke |
Conductivity Sensors
Industrial Inductive Conductivity and TDS Sensor · Ref. : DDG-GY-INDUSTRIAL-INDUCTIVE-CONDUCTIVITYTDS-SENSOR-3
Price on request
Conductivity Sensors
RS485 Modbus RTU IP68 Water Conductivity EC Sensor · Ref. : NBL-DDM-ONLINE-WATER-CONDUCTIVITY-SENSOR
Price on request
Conductivity Sensors
Industrial RS485 Water Electrical Conductivity Sensor IP68 · Ref. : SEN0707
Price on request
Conductivity Sensors
Online water conductivity controller with 4-20 mA outputs · Ref. : ONLINE_INLINE_WATER_CONDUCTIVITY_CONTROLLER
Price on request
No advertising or analytics cookies. A single, strictly necessary cookie is set only if you sign in to your account. Your quote basket and comparison stay in your browser. Details