RS-WS-*-YM-1-T – Leaf wetness sensor with temperature measurement

Leaf wetness sensor with temperature measurement

General Industrial Sensors & Transmitters

  • -40°C~60°C
  • -40°C~80°C
  • 0-100%RH
  • ±0.5°C(@25°C)
Manufacturer part number
LEAF-WETNESS-SENSOR
Manufacturer
Renke
Operating Temperature
-40°C~60°C
Temperature range
-40°C~80°C

Renke leaf wetness sensor designed to detect water and ice on a surface, used for monitoring in greenhouses, laboratories and open fields.

Product overview

Overview. The Renke RS-WS-*-YM-1-T leaf wetness sensor is a leaf-shaped sensor designed to measure surface moisture on plants. It detects traces of water and ice after installation.

Main characteristics. The sensor offers humidity accuracy of ±3% (0-50%, 25°C) over a 0-100%RH range, with a humidity resolution of 0.1%RH. Temperature accuracy is ±0.5°C (@25°C) with a temperature resolution of 0.1°C. The leaf-shaped surface has a vein density of 15 lines/cm, allowing detection of very small droplets. Dimensions are 65*15*138.5mm.

Interfaces and connectivity. The sensor is available with an RS485 output and with analog outputs 0-5V and 4-20mA or 0-10V depending on the version. The cable is 2 m by default, with custom lengths available.

Power and environment. Power supply is DC 5-30V for RS485, DC 10-30V for 0-5V and 4-20mA, and DC 18-30V for 0-10V. Maximum power consumption is 0.75W (RS485) and 0.9W (analog). Operating temperature ranges from -40°C to 60°C, and the temperature measurement range is -40°C to 80°C. Protection class is IP67, with black flame-retardant epoxy resin encapsulation.

Typical uses. Monitoring leaf surface wetness in greenhouses, laboratories, livestock farms, agricultural fields and gardens, for disease prevention and control of sprinkler irrigation.

Integration. Place the sensor next to the crops, pass the cable through the small hole at the front of the sensor, and hang it directly from tree branches. A non-metallic wire must be used for fixing.

See all specifications

Highlights

  • Humidity accuracy: ±3% (@0-50%, 25°C)
  • Dimensions: 65*15*138.5mm
  • Humidity range: 0-100%RH
  • Cable Length: 2m (default), custom length available
  • Humidity Resolution: 0.1%RH
  • Max Power Consumption: 0.75W (RS485), 0.9W (Analog)

Typical applications

Derived from the part category, not a compatibility statement.

Good to know before integrating

  • Thermal: rated operating range -40°C~60°C — check it against the installation environment.

See also

Technical questions

Ask a question

No published question about this part yet. Questions are reviewed before publication.