LoRa wireless data collection and control gateway (RS-LGH-*-*-T series) in a shielded metal enclosure, supporting up to 32 channels with RJ45 Ethernet or RS-485 upload.
Communication interface — LoRaLoRa spread spectrum communication
Communication interface — RS-485 interface485 communication
Data upload interval — 20-65535sDefault 30s
LoRa 485 data collector — RS-485-LORA-2-T — Slave 1 data — Slave 2 data — Slave 3 dataSlave 4 data
LoRa valve controller — RS-VPL-DC-LORA- 2-TNone
LoRa valve controller — RS-VPL-LORA-2-TNone
Product overview
Overview. Renke develops the RS-LGH-*-*-T LoRa gateway (reference LORA-GATEWAY) as a central relay station for distributed environmental monitoring and wireless valve control across large areas. Utilizing encrypted LoRa spread spectrum communication, it provides strong signal penetration and a valve control response time within 2 seconds.
Capacity and Variants. The -100 series supports up to 32 data acquisition channels, while the -200 series simultaneously handles 32 data acquisition channels and 32 control channels. Data upload (configurable interval from 20-65535s, default 30s) is performed via an RJ45 Ethernet port (models RS-LGH-100-ETH-T and RS-LGH-200-ETH-T) or an RS-485 interface (models RS-LGH-100-N01-T and RS-LGH-200-N01-T), with Bluetooth mobile app parameter configuration.
Industrial Design. Housed in a shielded sheet-metal enclosure with status indicator lights, the gateway operates on a wide DC 10~30V power supply compatible with on-site adapters or solar power systems.
LoRa wireless data collection and control gateway (RS-LGH-*-*-T series) in a shielded metal enclosure, supporting up to 32 channels with RJ45 Ethernet or RS-485 upload.
Communication interface — LoRaLoRa spread spectrum communication
Communication interface — RS-485 interface485 communication
Data upload interval — 20-65535sDefault 30s
LoRa 485 data collector — RS-485-LORA-2-T — Slave 1 data — Slave 2 data — Slave 3 dataSlave 4 data
LoRa valve controller — RS-VPL-DC-LORA- 2-TNone
2. Datasheet extract (recorded values)
Parameter
Value
Communication interface — LoRa
LoRa spread spectrum communication
Communication interface — RJ45 network port
Data upload via Ethernet port (supports ETH version only)
Communication interface — RS-485 interface
485 communication
Data upload interval — 20-65535s
Default 30s
Device configuration — Bluetooth
You can use the Neutral mobile app to configure Bluetooth gateway parameters.
LoRa 485 data collector — RS-485-LORA-2-T — Slave 1 data — Slave 2 data — Slave 3 data
Slave 4 data
LoRa valve controller — RS-VPL-DC-LORA- 2-T
None
LoRa valve controller — RS-VPL-LORA-2-T
None
LoRa valve controller — RS-WPL-LORA-2-T
None
Model
RS-LGH-*-*-T
Power supply range — DC 10~30V
DC wide voltage power supply
Applications and use cases
Architectures in which LORA-GATEWAY can play a role, derived from its category. This is not a compatibility statement: check the specifications against your requirements.
Energy bills give one total for the whole site. Submetering places meters and current sensors on each circuit or usage and collects their readings through a gateway, so consumption can be followed per building, floor or machine
To check
Number of circuits and phases to meter, and the current range of each
Wired Modbus bus or wireless LoRaWAN, depending on cabling access in the switchboards
Accuracy class required for internal allocation or for billing
Offices and classrooms get stuffy without anyone measuring why. Indoor air quality monitoring places CO2, VOC and particle sensors in the rooms and reports their values through a gateway, so ventilation can be adjusted to real occupancy
To check
Parameters to measure (CO2 alone or CO2, VOC and particles)
Battery-powered sensors or mains-powered sensors with display
Integration with the ventilation control or building management system
A leak under a sink or in a technical room is often found days later. Leak detection places wireless sensors where water can appear and sends an alert through a gateway as soon as one of them gets wet
To check
Locations at risk: kitchens, bathrooms, plant rooms, server rooms
Alert path (SMS, e-mail, application) and who receives it
Battery life and the way a low battery is reported
A fridge that drifts at night can ruin a whole stock. Temperature loggers in cold rooms and trucks report through a gateway or a tracker and raise an alert when a threshold is crossed
To check
Temperature range and accuracy required by the product
Record keeping required by the applicable regulations
A LoRaWAN project needs sensors, gateways, a network server and an application that work together. Sensor nodes report to indoor or outdoor gateways, which forward the data to the network server and the customer’s platform
To check
Regional frequency plan (EU868, US915 and others)
Network server: public, private or embedded in the gateway
A building’s energy, comfort and occupancy data sit in separate systems. Sensors, meters and gateways feed one model of the building, room by room, to compare scenarios and steer the installations
Milesight sensors, LoRaWAN gateways and cellular routers can be brought together on the Milesight Development Platform, which manages the devices and passes their data to other applications through an API and webhooks
To check
Development Platform for device management, API and webhooks, or another network server and application
Devices provisioned through Milesight RPS must have that provisioning removed before being added to the Development Platform
Data flows to the customer’s own application through webhooks
RAKwireless WisGate gateways run WisGateOS 2 and are managed from WisDM, RAKwireless’ cloud device management platform with a built-in network server, alongside RAK sensor nodes, radio modules and concentrators
To check
WisDM built-in network server, or a third-party one (ChirpStack, TTN/TTS, AWS IoT Core, Actility)
Remote configuration and updates of the gateways from WisDM
Regional frequency plan of the gateways and nodes
Associated system blocks
GatewaysSensors and modulesDevelopment boardsMounting
Need a complete solution?
Send a request for LORA-GATEWAY and the other parts of your project.
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
Current productRenke
LORA-GATEWAY
LoRa wireless data acquisition gateway with RJ45 or RS-485 interface
Communication interface — LoRa
LoRa spread spectrum communication
Communication interface — RS-485 interface
485 communication
Data upload interval — 20-65535s
Default 30s
LoRa 485 data collector — RS-485-LORA-2-T — Slave 1 data — Slave 2 data — Slave 3 data
What is recorded about the regulatory status and the life of this part.
Regulatory compliance
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
No advertising or analytics cookies. A single, strictly necessary cookie is set only if you sign in to your account. Your quote basket and comparison stay in your browser. Details