Wall-mounted electrochemical nitrogen dioxide NO2 sensor for leak monitoring and gas concentration tracking in industrial facilities.
Measure range0-20ppm/0-2000ppm
Average power consumption0.18W
Accuracy±5%FS
Response time20ppm: ≤30s, 2000ppm: ≤60s
ModelRS-NO2-*-2-T
Power supply10~30V DC
Product overview
Overview. The Renke nitrogen dioxide sensor RS-NO2-*-2-T is an industrial NO2 gas sensor with wall-mounted installation, model RS-NO2-*-2-T. It measures nitrogen dioxide over 0-20 ppm or 0-2000 ppm ranges, with other ranges customizable.
Main characteristics. Measurement accuracy is ±5%FS and repeatability is ≤2%. Resolution is 0.1 ppm on the 20 ppm range and 1 ppm on the 2000 ppm range. Stability is ≤2% of signal value per month, with zero drift of ≤±0.5 ppm on 20 ppm and ≤±20 ppm on 2000 ppm. Response times are ≤30 s on 20 ppm and ≤60 s on 2000 ppm, with a warm-up time of at least 5 min.
Interfaces and connectivity. The sensor provides RS485, 4-20 mA, 0-5 V and 0-10 V outputs, allowing connection to a PLC or supervision system. An OLED display is available as an option for on-site reading.
Power and environment. It is powered from 10 to 30 V DC and draws an average of 0.18 W. It operates between -20 and 50 °C, at 15 to 90 %RH non-condensing, and a working pressure of 91 to 111 kPa.
Typical uses. The RS-NO2-*-2-T is suited to nitrogen dioxide leak monitoring in industrial environments where worker exposure must be tracked in real time.
Integration. The ducted version RS-NO2-*-2FL-*-T, with waterproof housing and flange mounting, is intended for measurement in enclosed pipelines.
Wall-mounted electrochemical nitrogen dioxide NO2 sensor for leak monitoring and gas concentration tracking in industrial facilities.
Measure range0-20ppm/0-2000ppm
Average power consumption0.18W
Accuracy±5%FS
Response time20ppm: ≤30s, 2000ppm: ≤60s
ModelRS-NO2-*-2-T
2. Datasheet extract (recorded values)
Parameter
Value
Response time
20ppm: ≤30s, 2000ppm: ≤60s
Accuracy
±5%FS
Average power consumption
0.18W
Measure range
0-20ppm/0-2000ppm
Model
RS-NO2-*-2-T
Power supply
10~30V DC
Repeatability
≤2%
Resolution
20ppm: 0.1ppm, 2000ppm: 1ppm
Signal Output
RS485/4-20mA/0-5V/0-10V
Stability
≤2% signal value/month
Warm-Up Time
≥5min
Working Environment
-20~50℃, 15~90%RH non-condensing
Working Pressure
91~111kPa
Zero Drift
20ppm: ≤±0.5ppm, 2000ppm: ≤±20ppm
Applications and use cases
Architectures in which RS-NO2 can play a role, derived from its category. This is not a compatibility statement: check the specifications against your requirements.
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
What is recorded about the regulatory status and the life of this part.
Regulatory compliance
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.