RS-SG-*-*-*-2-T – Electrochemical and semiconductor odor sensor with RS485

Electrochemical and semiconductor odor sensor with RS485

Environmental and Gas Sensors

  • 90~110kPa
  • 0.18W
  • ≤80s
  • 10~30V DC
Manufacturer part number
ODOR-SENSOR
Manufacturer
Renke
Pressure range
90~110kPa
Average power consumption
0.18W

Renke RS-SG-*-*-*-2-T odor sensor for measuring odor concentration in landfills and public restrooms, with RS485, 4-20 mA and voltage outputs.

Product overview

Overview. The Renke RS-SG-*-*-*-2-T is an ambient gas sensor using electrochemical or semiconductor principles to measure odor concentration, a mixture of several gases produced by food decay or animal waste. It is wall mounted.

Main characteristics. Measuring range of 0~5 ppm for the electrochemical type and 0.3~3 ppm for the semiconductor type, resolution of 0.001 ppm, repeatability within 2%, response time of 80 s or less and preheating time of at least 5 min. Accuracy is ±5%FS (H2S, 500 ppb) for the high-precision type, ±10%FS (H2S, 5 ppm) for the electrochemical type and ±13%FS (C2H6O, 5 ppm, 20 ℃, 65%RH) for the semiconductor type. Zero drift is ±0.5 ppm and electrochemical stability is 10% of the signal value or less per year.

Interfaces and communication. RS485, 4-20 mA, 0-5 V and 0-10 V outputs, with Modbus RTU communication. Relay outputs can be customized on up to two channels for linkage control.

Power and environment. 10~30 V DC supply, average power consumption of 0.18 W. Operating range -20 to 50 ℃, 15~90%RH non-condensing. IP65 housing with built-in waterproof sealing strips and a waterproof, breathable membrane.

Typical uses. Monitoring odor concentration in garbage dumps, pig farms and public restrooms. Connection to PLCs, HMI screens or Modbus RTU compatible supervision software, with triggering of fans or solenoid valves when the set limit is exceeded.

Limitations. The manufacturer indicates a relatively short lifespan, modest accuracy, notable sensitivity to ambient temperature and humidity, average stability, and measured values that may fluctuate.

See all specifications

Highlights

  • Pressure range: 90~110kPa
  • Response time: ≤80s
  • Accuracy — ±10%FS(@H2S, 5ppm) — ±5%FS(@H2S, 500ppb): ±13%FS(@C2H60, 5ppm,20℃, 65%RH)
  • Average power consumption: 0.18W
  • Measuring Range: 0~5ppm (electrochemical type), 0.3~3ppm (semiconductor type)
  • Model: RS-SG-*-*-*-2-T

Typical applications

Derived from the part category, not a compatibility statement.

See also

Technical questions

Ask a question

No published question about this part yet. Questions are reviewed before publication.

Request a quote