RS-ORP-N01-3-T – Integrated ORP sensor with RS485 Modbus-RTU output
Integrated ORP sensor with RS485 Modbus-RTU output
- 0~80℃
- 0.3W
- 1 year
- 0.6MPa
- Manufacturer part number
- ORP-SENSOR
- Manufacturer
- Renke
- Power consumption
- 0.3W
- Electrode service life
- 1 year
Integrated oxidation reduction potential (ORP) sensor with a platinum combination electrode and RS485 Modbus-RTU output, designed for online water quality monitoring.
- Electrode operating temperature0~80℃
- ORP measurement range-1999~1999mV (Resolution: 1mV)
- Temperature measurement range0~60℃ (Resolution: 0.1℃)
- Power consumption0.3W
- Component temp and RH resistance-20℃~+80℃, 0%RH~95%RH (Non-condensing)
- Electrode service life1 year
Product overview
Renke RS-ORP-N01-3-T. integrated ORP sensor measuring oxidation reduction potential, with RS485 output using the standard Modbus-RTU protocol, designed for online measurement in aqueous solutions.
Measurement. ORP measurement range of -1999 to 1999 mV with a resolution of 1 mV and a measurement error of ≤±5 mV (25 ℃, 222 mV standard solution). Temperature measurement range of 0 to 60 ℃ with a resolution of 0.1 ℃ and an error of ±0.5 ℃.
Communication and outputs. RS485 interface with Modbus-RTU protocol, default baud rate of 4800, adjustable from 1200 to 115200 bauds. Signal outputs available as 4-20 mA, 0-5 V and 0-10 V.
Power and environment. DC power supply of 7 to 30 V, power consumption of 0.3 W. Protection class IP68. Operating conditions of 0 to 60 ℃, electrode operating temperature of 0 to 80 ℃, pressure resistance of 0.6 MPa. Component temperature and relative humidity resistance of -20 ℃ to +80 ℃ and 0 % to 95 % RH, non-condensing.
Installation. Default cable length of 5 m, customizable on request, and default electrode wire length of 5 m, customizable to 10 m, 15 m or 20 m. Electrode service life stated as 1 year.
Typical uses. Online monitoring of redox potential in industrial wastewater, river, lake and aquaculture water, with the RS485 Modbus-RTU output allowing connection to a computer or a centralised supervision system.
Highlights
- Cable Length: Default 5m (Other lengths can be customized)
- Component temp and RH resistance: -20℃~+80℃, 0%RH~95%RH (Non-condensing)
- Electrode operating temperature: 0~80℃
- Electrode service life: 1 year
- Electrode wire length: default 5m (10m, 15m, 20m customizable)
- Electrode withstand voltage: 0.6MPa
Good to know before integrating
- Thermal: rated operating range 0~80℃ — check it against the installation environment.
Technical questions
No published question about this part yet. Questions are reviewed before publication.
Complete specifications
Every characteristic recorded for ORP-SENSOR, with where it comes from. Use the filters to find one quickly.
All specifications (18)
| Characteristic | Value |
|---|---|
| Cable Length | Default 5m (Other lengths can be customized) |
| Communication interface | RS485, standard ModBus-RTU protocol. Communication baud rate: default 4800 (1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200 adjustable). |
| Component temp and RH resistance | -20℃~+80℃, 0%RH~95%RH (Non-condensing) |
| Electrode operating temperature | 0~80℃ |
| Electrode service life | 1 year |
| Electrode wire length | default 5m (10m, 15m, 20m customizable) |
| Electrode withstand voltage | 0.6MPa |
| Model | RS-ORP-N01-3-T |
| Operating Conditions | 0~60℃ |
| ORP measurement error | ≤±5mV (25℃, 222mV standard solution) |
| ORP measurement range | -1999~1999mV (Resolution: 1mV) |
| Output signal | 4-20mA/0-5V/0-10V |
| Power consumption | 0.3W |
| Power supply | DC 7~30V |
| Pressure Resistance | 0.6MPa |
| Protection Class | IP68 |
| Temperature measurement error | ±0.5℃ |
| Temperature measurement range | 0~60℃ (Resolution: 0.1℃) |
No specification matches.
Last verification : 2026-11-02
Technical documentation
Official documents and the technical data recorded for ORP-SENSOR. For a missing document or a specific revision, our experts send it to you.
Contents
Overview Datasheet extract Official documents1. Technical overview
Integrated oxidation reduction potential (ORP) sensor with a platinum combination electrode and RS485 Modbus-RTU output, designed for online water quality monitoring.
2. Datasheet extract (recorded values)
| Parameter | Value |
|---|---|
| Cable Length | Default 5m (Other lengths can be customized) |
| Communication interface | RS485, standard ModBus-RTU protocol. Communication baud rate: default 4800 (1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200 adjustable). |
| Component temp and RH resistance | -20℃~+80℃, 0%RH~95%RH (Non-condensing) |
| Electrode operating temperature | 0~80℃ |
| Electrode service life | 1 year |
| Electrode wire length | default 5m (10m, 15m, 20m customizable) |
| Electrode withstand voltage | 0.6MPa |
| Model | RS-ORP-N01-3-T |
| Operating Conditions | 0~60℃ |
| ORP measurement error | ≤±5mV (25℃, 222mV standard solution) |
| ORP measurement range | -1999~1999mV (Resolution: 1mV) |
| Output signal | 4-20mA/0-5V/0-10V |
| Power consumption | 0.3W |
| Power supply | DC 7~30V |
| Pressure Resistance | 0.6MPa |
| Protection Class | IP68 |
| Temperature measurement error | ±0.5℃ |
| Temperature measurement range | 0~60℃ (Resolution: 0.1℃) |
Integration
Points to check before using ORP-SENSOR in a design. They are derived from the recorded characteristics, not from the manufacturer's application circuits.
Power and communication
| Electrode withstand voltage | 0.6MPa |
| Power consumption | 0.3W |
| Power supply | DC 7~30V |
Check the exact pin assignment and the application circuit in the datasheet, or ask our experts.
Implementation checklist
- Thermal : rated operating range 0~80℃ — check it against the installation environment.
Technical FAQ
Answers to the questions that the recorded characteristics of ORP-SENSOR can answer. A question is not asked when nothing is recorded to answer it.
1Does it support RS-485?
Yes — recorded under "Communication interface": RS485, standard ModBus-RTU protocol. Communication baud rate: default 4800 (1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200 adjustable)..
2Does it support CAN bus?
Yes — recorded under "Cable Length": Default 5m (Other lengths can be customized).
3Does it support Modbus?
Yes — recorded under "Communication interface": RS485, standard ModBus-RTU protocol. Communication baud rate: default 4800 (1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200 adjustable)..
4What is the operating temperature range?
0~80℃ (source: Electrode operating temperature).
Compliance, lifecycle and traceability
What is recorded about the regulatory status and the life of this part.
Regulatory compliance
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
Lifecycle and product statusStatus not stated
- In production
- Not recommended for new designs
- End of life
- Obsolete
| Current status | Status not stated |
| Key dates | Not recorded |
Manufacturer references
| Manufacturer part number | ORP-SENSOR |
| Manufacturer | Renke |