RS-O3-*-2-*-T – Electrochemical ozone sensor with RS485 output, wall-mounted
Electrochemical ozone sensor with RS485 output, wall-mounted
- 0~10ppm/0~100ppm
- 0~10.00ppm/0~100ppm
- 0.12W
- ≤180s
- Manufacturer part number
- RS-O3
- Manufacturer
- Renke
- Measuring Range
- 0~10ppm/0~100ppm
- O3 range
- 0~10.00ppm/0~100ppm
Electrochemical ozone O3 concentration sensor for long-term monitoring at fixed sites, with RS485, 0-5 V, 0-10 V or 4-20 mA output and data updated every second.
- Measuring Range0~10ppm/0~100ppm
- O3 range0~10.00ppm/0~100ppm
- Average power consumption — 0.1W0.12W
- Power Consumption — 0.1W0.12W
- Response time≤180s
- Data update1s
Product overview
The Renke RS-O3-*-2-*-T is an electrochemical ozone O3 sensor for continuous monitoring at a fixed location. According to the manufacturer, several units can be installed at different points and their data uploaded to Renke's free cloud platform for centralised remote monitoring.
Measurement principle and ranges. The electrochemical cell responds within 180 s or less. Two measuring ranges are available, 0-10 ppm and 0-100 ppm, with a resolution of 0.01 ppm on the first and 0.1 ppm on the second. Accuracy is ±6% FS at 5 ppm on the 0-10 ppm range and at 50 ppm on the 0-100 ppm range, at 25 °C and 50% RH.
Outputs and integration. The signal is available as RS485, 0-5 V, 0-10 V or 4-20 mA, and data are updated every second. The sensor runs from 10 to 30 V DC and draws an average of 0.12 W.
Stability and operating conditions. Zero drift is ±1% FS, repeatability is 2% or less, and stability is 7% of signal value or less per year. A warm-up of at least 5 minutes is required. The sensor operates between -10 °C and 55 °C and 15% to 90% RH without condensation, at a pressure of 91 to 111 kPa.
Highlights
- Response time: ≤180s
- Average power consumption — 0.1W: 0.12W
- Data update: 1s
- Measuring Range: 0~10ppm/0~100ppm
- Model: RS-O3-*-2-*-T
- O3 range: 0~10.00ppm/0~100ppm
Technical questions
No published question about this part yet. Questions are reviewed before publication.
Complete specifications
Every characteristic recorded for RS-O3, with where it comes from. Use the filters to find one quickly.
All specifications (20)
| Characteristic | Value |
|---|---|
| Response time | ≤180s |
| Accuracy | 0-10ppm: ±6%FS (@5ppm, 25°C, 50%RH), 0-100ppm: ±6%FS (@50ppm, 25°C, 50%RH) |
| Average power consumption — 0.1W | 0.12W |
| Data update | 1s |
| Measuring Range | 0~10ppm/0~100ppm |
| Model | RS-O3-*-2-*-T |
| O3 range | 0~10.00ppm/0~100ppm |
| Operating Environment | -10℃~55℃, 15%RH~90%RH (non-condensing) |
| Operating Pressure | 91~111kPa |
| Output signal — RS485 | 0-5V/0-10V/4-20mA |
| Power Consumption — 0.1W | 0.12W |
| Power supply | 10~30V DC |
| Preheating Time | ≥5min |
| Repeatability | ≤2% |
| Resolution | 0.01ppm (0~10ppm), 0.1ppm (0~100ppm) |
| Stability | ≤7% signal value/year |
| Warm-Up Time | ≥5min |
| Working Environment | -10℃~55℃, 15%RH-90%RH (no condensation) |
| Working Pressure | 91~111kPa |
| Zero Drift | ±1%FS |
No specification matches.
Last verification : 2026-11-02
Technical documentation
Official documents and the technical data recorded for RS-O3. For a missing document or a specific revision, our experts send it to you.
Contents
Overview Datasheet extract Official documents1. Technical overview
Electrochemical ozone O3 concentration sensor for long-term monitoring at fixed sites, with RS485, 0-5 V, 0-10 V or 4-20 mA output and data updated every second.
2. Datasheet extract (recorded values)
| Parameter | Value |
|---|---|
| Response time | ≤180s |
| Accuracy | 0-10ppm: ±6%FS (@5ppm, 25°C, 50%RH), 0-100ppm: ±6%FS (@50ppm, 25°C, 50%RH) |
| Average power consumption — 0.1W | 0.12W |
| Data update | 1s |
| Measuring Range | 0~10ppm/0~100ppm |
| Model | RS-O3-*-2-*-T |
| O3 range | 0~10.00ppm/0~100ppm |
| Operating Environment | -10℃~55℃, 15%RH~90%RH (non-condensing) |
| Operating Pressure | 91~111kPa |
| Output signal — RS485 | 0-5V/0-10V/4-20mA |
| Power Consumption — 0.1W | 0.12W |
| Power supply | 10~30V DC |
| Preheating Time | ≥5min |
| Repeatability | ≤2% |
| Resolution | 0.01ppm (0~10ppm), 0.1ppm (0~100ppm) |
| Stability | ≤7% signal value/year |
| Warm-Up Time | ≥5min |
| Working Environment | -10℃~55℃, 15%RH-90%RH (no condensation) |
| Working Pressure | 91~111kPa |
| Zero Drift | ±1%FS |
Technical FAQ
Answers to the questions that the recorded characteristics of RS-O3 can answer. A question is not asked when nothing is recorded to answer it.
1Does it support RS-485?
Yes — recorded under "Output signal — RS485": 0-5V/0-10V/4-20mA.
Compliance, lifecycle and traceability
What is recorded about the regulatory status and the life of this part.
Regulatory compliance
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
Lifecycle and product statusStatus not stated
- In production
- Not recommended for new designs
- End of life
- Obsolete
| Current status | Status not stated |
| Key dates | Not recorded |
Manufacturer references
| Manufacturer part number | RS-O3 |
| Manufacturer | Renke |