RS-GH-*-AL-T – PAR Sensor for Photosynthetically Active Radiation with RS485 Output

PAR Sensor for Photosynthetically Active Radiation with RS485 Output

Environmental and Gas Sensors

  • 0~2500μmol/㎡·s
  • 0.1s
  • ≤±2%
  • 60cm (customizable)
Manufacturer part number
PAR-SENSOR
Manufacturer
Renke
Measuring Range
0~2500μmol/㎡·s
Response time
0.1s

Photosynthetically active radiation (PAR) sensor measuring light intensity between 400 and 700 nm, for photosynthesis monitoring outdoors or on a weather station.

Product overview

Overview. The Renke RS-GH-*-AL-T is a photosynthetically active radiation (PAR) sensor that measures the light intensity used by photosynthesis. It covers a measuring range of 0 to 2500 μmol/m²·s with a resolution of 1 μmol/m²·s and a response time of 0.1 s.

Main characteristics. Accuracy is ±5% (1000 μmol/m²·s, @550 nm, 60% RH, 25 ℃), annual stability is less than or equal to ±2% and nonlinearity is less than or equal to ±1%. The response spectrum extends from 400 nm to 700 nm. The sensor uses a high-precision photoelectric sensing element and a high-quality cosine corrector for a standard cosine response.

Interfaces and connectivity. The sensor provides RS485, 4-20 mA, 0-5 V and 0-10 V outputs. The cable is 60 cm long, with customizable length.

Power and environment. The power supply is 7 V to 30 V DC (the 0-10 V output only accepts a 24 V DC supply). Power consumption is 0.06 W on the 485 output and 0.7 W on the 4-20 mA, 0-5 V or 0-10 V outputs. The operating temperature ranges from -25 °C to 60 °C. The aluminium housing is waterproof, with an IP67 protection rating stated by the manufacturer.

Typical uses. The sensor can be used alone for outdoor monitoring of the radiation that drives photosynthesis, or mounted on a fixed weather station. It suits measuring light from all sources used to grow plants, and according to the manufacturer also fields such as meteorology, agriculture and air pollution monitoring.

Integration. The RS485 output allows connection to an acquisition system or a PLC. Data can also be sent to the free cloud platform provided by the manufacturer.

See all specifications

Highlights

  • Response time: 0.1s
  • Accuracy: ±5%(1000umol/㎡·s, @550nm,60%RH,25℃)
  • Annual Stability: ≤±2%
  • Cable Length: 60cm (customizable)
  • Measuring Range: 0~2500μmol/㎡·s
  • Model: RS-GH-*-AL-T

Typical applications

Derived from the part category, not a compatibility statement.

See also

Technical questions

Ask a question

No published question about this part yet. Questions are reviewed before publication.