Renke soil water potential sensor measuring water availability to plants from -5 to -100 kPa, with RS485 output using the Modbus protocol.
Operating Temperature-40℃~+60℃
Measure range-5~-100kPa
Max Power Consumption0.25W (DC12V)
Accuracy±(10% current reading + 2kPa)
-10 ~ -30Field holding capacity
-30 ~ -100Gradually dry
Product overview
Overview. The Renke RS-SWP-N01-TR-1-T soil water potential sensor is a measuring instrument that determines the availability of soil water to plants by detecting pressure or tension changes in its sensitive element. Its ceramic construction limits signal drift caused by material degradation.
Main characteristics. Measuring range of -5 to -100 kPa with a resolution of 0.1 kPa and an accuracy of ±(10% of the current reading + 2 kPa). The sensor is rated for an operating temperature of -40 ℃ to +60 ℃ and has a maximum power consumption of 0.25 W at DC 12 V.
Interfaces and connectivity. RS485 output using the Modbus protocol, allowing connection to a data acquisition system or a compatible controller.
Power and environment. Power supply DC 5 to 30 V, protection level IP68. The cable is supplied at 2 m by default, other lengths can be customized on request.
Typical uses. Continuous monitoring of soil moisture status for irrigation management, agricultural production and ecological research, with measurements suited to long-term field monitoring.
No published question about this part yet. Questions are reviewed before publication.
Complete specifications
Every characteristic recorded for RS-SWP-N01-TR-1-T, with where it comes from. Use the filters to find one quickly.
All specifications (13)
Characteristic
Value
-10 ~ -30
Field holding capacity
-30 ~ -100
Gradually dry
Accuracy
±(10% current reading + 2kPa)
Below -100
Drought
Max Power Consumption
0.25W (DC12V)
Measure range
-5~-100kPa
Model
RS-SWP-N01-TR-1-T
Operating Temperature
-40℃~+60℃
Output signal
RS485 (ModBus protocol)
Power supply
DC 5-30V
Protection Level
IP68
Resolution
0.1kPa
Wire length
2m by default, other lengths can be customized
No specification matches.
Last verification : 2026-11-02
Integration
Points to check before using RS-SWP-N01-TR-1-T in a design. They are derived from the recorded characteristics, not from the manufacturer's application circuits.
1Thermalrated operating range -40℃~+60℃ — check it against the installation environment.
Power and communication
Max Power Consumption
0.25W (DC12V)
Power supply
DC 5-30V
Check the exact pin assignment and the application circuit in the datasheet, or ask our experts.
Implementation checklist
Thermal : rated operating range -40℃~+60℃ — check it against the installation environment.
Applications and use cases
Architectures in which RS-SWP-N01-TR-1-T can play a role, derived from its category. This is not a compatibility statement: check the specifications against your requirements.
Answers to the questions that the recorded characteristics of RS-SWP-N01-TR-1-T can answer. A question is not asked when nothing is recorded to answer it.
1Does it support RS-485?
Yes — recorded under "Output signal": RS485 (ModBus protocol).
2Does it support CAN bus?
Yes — recorded under "Wire length": 2m by default, other lengths can be customized.
3Does it support Modbus?
Yes — recorded under "Output signal": RS485 (ModBus protocol).
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
What is recorded about the regulatory status and the life of this part.
Regulatory compliance
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
No advertising or analytics cookies. A single, strictly necessary cookie is set only if you sign in to your account. Your quote basket and comparison stay in your browser. Details